GW26-e5405 Establishment of Swine End-Stage Dilated Cardiomyopathy Model by Percutaneous Venous Intervention
The DCM group underwent rapid right ventricular pacing by a modified Medtronic unipolar pacemaker connected to an apical pacing lead via percutaneous venous intervention, which at the rate of 230 beats per minute for 4 weeks, and 190 beats per minute for another 4 weeks, while the control group rece...
Saved in:
Published in | Journal of the American College of Cardiology Vol. 66; no. 16; p. C101 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
New York
Elsevier Inc
20.10.2015
Elsevier Limited |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The DCM group underwent rapid right ventricular pacing by a modified Medtronic unipolar pacemaker connected to an apical pacing lead via percutaneous venous intervention, which at the rate of 230 beats per minute for 4 weeks, and 190 beats per minute for another 4 weeks, while the control group received sham operation. |
---|---|
ISSN: | 0735-1097 1558-3597 |
DOI: | 10.1016/j.jacc.2015.06.391 |