Comparison of primary pressure standards of METAS and CMI in the range 50–600 kPa
A supplementary bilateral comparison was carried out to compare the pressure defined by the CMI (Czech Republic) and the METAS (Switzerland). This comparison was motivated by the introduction of new measuring equipment in these laboratories. The transfer standard of the comparison is a piston-cylind...
Saved in:
Published in | Metrologia Vol. 43; no. 1A; p. 07002 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
IOP Publishing
01.01.2006
|
Online Access | Get full text |
Cover
Loading…
Summary: | A supplementary bilateral comparison was carried out to compare the pressure defined by the CMI (Czech Republic) and the METAS (Switzerland). This comparison was motivated by the introduction of new measuring equipment in these laboratories. The transfer standard of the comparison is a piston-cylinder of about 10 cm2 whose effective area was determined at nine different values of pressure between 50 kPa and 600 kPa. The effective areas determined by the two laboratories are equivalent within the uncertainties. The results obtained by cross-floating are also in agreement with dimensional characterization of the transfer standard. This comparison is registered as Euromet project 788. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
ISSN: | 0026-1394 1681-7575 |
DOI: | 10.1088/0026-1394/43/1A/07002 |