Comparative study of some mechanical properties of cobalt chromium and polyether ether ketone thermoplastic removable partial denture clasps: an In-vitro Study

Objective: was to evaluate the retentive force, fatigue resistance and deformity of clasps made from two materials cobalt chromium and poly ether et her ketone (PEEK). Material and Methods: sixteen models were fabricated, each one having lower 1st molar. Models were divided into two groups according...

Full description

Saved in:
Bibliographic Details
Published inBrazilian dental science Vol. 23; no. 3
Main Authors El-Baz, Rady, Fayad, Mostafa, Abas, Mohamed, Shoieb, Ahmed, Gad, Mohammed, Helal, Mohamed Ahmed
Format Journal Article
LanguageEnglish
Published 01.07.2020
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective: was to evaluate the retentive force, fatigue resistance and deformity of clasps made from two materials cobalt chromium and poly ether et her ketone (PEEK). Material and Methods: sixteen models were fabricated, each one having lower 1st molar. Models were divided into two groups according to materials, group I (GI) for cobalt chromium (Co-Cr) and group II (GII) for PEEK. Each testing models and its clasps were mounted inside universal testing machine, the retention was measured by applying withdrawal force to it by this machine at 5 mm/min. The Fatigue resistance is measured by the reduction in retention through repeated insertion and removal cycles using robot a chewing simulator. Removal and insertion cycling of clasps was carried out for 360, 730, 1080, 1,440,2,116 and 2,880 cycles (corresponding to 3,6,9,12, 18 and 24 months of simulated clinical use of a RPD) to simulate the fatigue resistance test. Deformity was measured before and after each cycling using a digital micrometer. Statistical analysis was done by 2-way-ANOVA test to detect significance effects of each variable. Results: Retention and fatigue resistance, after 360,730, 1080, 1,440,2,116 and 2,880 cycles totally the difference between Co-Cr and PEEK groups was statistically non-significant (P = 0.0980>0.05) where (Co-Cr > PEEK). Deformation results, regardless to evaluation time, Co-Cr group recorded statistically significant higher deformation mean value than PEEK group (P = 0.008<0.05). Regardless to material group, deformation mean value changed non significantly by time (P = 0.2882> 0.05). Conclusion: PEEK clasps (1.0 mm in cross section diameter) engage 0.50 mm undercut provide sufficient retention nearly similar that of Co-Cr clasps.KeywordsFlexible clasps; Polyether ether ketone, PEEK; Thermoplastic resin; Partial denture.
ISSN:2178-6011
2178-6011
DOI:10.14295/bds.2020.v23i3.1935