Microbiologique Microfilm™ EBEc – a Rapid Method for the Simultaneous Enumeration of Enterobacteriaceae and Escherichia coli
Abstract Background The Enterobacteriaceae and generic Escherichia coli are routinely enumerated in foods as part of product release criteria, or in the case of swabs, for environmental monitoring. Objective Microbiologique Microfilm™ EBEc is intended to provide a rapid and easy-to-use method for si...
Saved in:
Published in | Journal of AOAC International Vol. 103; no. 5; pp. 1348 - 1360 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
01.09.2020
|
Online Access | Get full text |
Cover
Loading…
Summary: | Abstract
Background
The Enterobacteriaceae and generic Escherichia coli are routinely enumerated in foods as part of product release criteria, or in the case of swabs, for environmental monitoring.
Objective
Microbiologique Microfilm™ EBEc is intended to provide a rapid and easy-to-use method for simultaneous enumeration of Enterobacteriaceae and E. coli on foods and environmental surfaces. Methods: This study evaluated the performance of Microfilm™ EBEc against ISO methods (ISO 21528-2:2017 for Enterobacteriaceae and ISO 16649-2: 2001 for E. coli) in 20 food matrixes and two environmental surfaces. Inclusivity, exclusivity, lot-to-lot reproducibility, ruggedness and stability studies were also performed on Microfilm™ EBEc.
Results
No significant differences and high correlation coefficients (R2) were observed between the Microfilm™ EBEc and the corresponding ISO methods in spiked food matrixes and environmental samples. Inclusivity studies showed expected results for all the E. coli and Enterobacteriaceae strains tested. In terms of exclusivity testing, all the strains tested failed to grow on Microfilm™ EBEc. A lot-to-lot study showed no significant differences in mean difference (log10) counts among the three lots of the Microfilm™ EBEc. Ruggedness studies showed no significant differences in mean difference (log10) counts at varying incubation temperatures and times. Stability studies on the Microfilm™ EBEc showed that it is stable at 2–25°C for 12 months, and at 45°C for 6 weeks.
Conclusions
The results of this study indicate that the Microfilm™ EBEc is equivalent to the corresponding ISO methods for enumeration of Enterobacteriaceae and E. coli. Highlights: Microfilm™ EBEc offers a convenient and relatively fast test method for simultaneous enumeration of Enterobacteriaceae and E. coli in 24 h and has an advantage over the corresponding ISO methods that require two assays on the same sample for enumeration of Enterobacteriaceae and E. coli Gram-negative indicator groups. |
---|---|
ISSN: | 1060-3271 1944-7922 |