Selective symptomatic therapy of macular edema due to occlusive processes in retinal venous system

to evaluate the effect of dexamethasone intravitreal implant on the functional state of the eye in macular edema associated with central retinal vein occlusion. The study included two groups of patients: group 1 (control group) - 8 patients (16 eyes) without ocular pathology and group 2 (study group...

Full description

Saved in:
Bibliographic Details
Published inVestnik oftal'mologii Vol. 133; no. 2; p. 18
Main Authors Bikbov, M M, Fayzrakhmanov, R R, Gil'manshin, T R
Format Journal Article
LanguageRussian
Published Russia (Federation) 2017
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:to evaluate the effect of dexamethasone intravitreal implant on the functional state of the eye in macular edema associated with central retinal vein occlusion. The study included two groups of patients: group 1 (control group) - 8 patients (16 eyes) without ocular pathology and group 2 (study group) - 8 patients (8 eyes) with macular edema on the background of newly diagnosed thrombosis of the central retinal vein. All the patients from the study group underwent insertion of an intravitreal dexamethasone implant - Ozurdex. Best corrected visual acuity (BCVA) and retinal light sensitivity of the central visual field were followed up. The maximum follow-up period was 12 months. In group 1 (controls), BCVA averaged 0.93±0.2 and retinal light sensitivity of the central visual field - 19.01±1.18 dB. In group 2, baseline BCVA and retinal light sensitivity were 0.08±0.02 and 4.23±0.2 dB, 1 month after Ozurdex implantation - 0.21±0.04 and 11.77±0.98 dB, at 12 months - 0.23±0.17 and 5.2±0.78 dB, respectively. Macular edema associated with central retinal vein thrombosis has a strong deteriorating effect on the functional state of the eye. The dexamethasone intravitreal implant in patients with postthrombotic macular edema contributes to functional improvement, including BCVA and light sensitivity of the central retina, over the first year. At that, different functional parameters show different dynamics after dexamethasone treatment. Light sensitivity values, in contrast to BCVA, change unevenly and significantly during the year. Intravitreal implantation of a dexamethasone implant in patients with postthrombotic macular edema is an effective symptomatic treatment of occlusive processes within the retinal venous system.
ISSN:0042-465X