Falling Estimation Based on PoseNet Using Camera with Difference Absolute Standard Deviation Value and Average Amplitude Change on Key-Joint

Elderly people need special attention and some of them need to be monitored continuously and in real-time. Fall detection is one of the systems used to monitor the daily life of the elderly. Various devices and methods were developed to monitor the condition of the elderly on daily activity. The sys...

Full description

Saved in:
Bibliographic Details
Published inApplied mechanics and materials Vol. 913; pp. 111 - 120
Main Authors Siddiq, Muhammad Idris, Rizal, Achmad, Erfianto, Bayu, Hadiyoso, Sugondo
Format Journal Article
LanguageEnglish
Published Zurich Trans Tech Publications Ltd 03.03.2023
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Elderly people need special attention and some of them need to be monitored continuously and in real-time. Fall detection is one of the systems used to monitor the daily life of the elderly. Various devices and methods were developed to monitor the condition of the elderly on daily activity. The system that has been proposed in previous studies uses a number of sensors that are placed on the body. However, this system tends to be high cost, complex installation, and inconvenient to use. Therefore, an alternative system is needed to overcome this problem. The purpose of this study is to developed a fall detection method using PoseNet with pose calculations based on key joins. Testing on larger data sets is needed to verify the proposed method's performance further. The use of cameras can be a solution to monitoring the activities of the elderly. With the image processing method, it is possible to estimate the activities of the elderly. The purpose of this study is to developed a fall detection method using PoseNet with pose calculations based on key joins. This study developed a fall detection method using PoseNet with pose calculations based on key joins. The key-join used is Left and Right Shoulder and is only measured at the y-coordinate. We calculated the difference absolute standard deviation value (DASDV) and average amplitude change (AAC) on the Y-coordinate. From 10 falling and non-falling conditions trials, we obtained 85% and 80% accuracy for AAC and DASDV. The result of this research can be used as a source or comparison for future research.
Bibliography:Special topic volume with invited peer-reviewed papers only
ISSN:1660-9336
1662-7482
1662-7482
DOI:10.4028/p-9cplm1