Evaluation of Clinical Fetal Brain MRI Motion Correction for 3D Image Formation
In the clinical application of the method, 24 cases demonstrated high visual accuracy with no manual intervention (Figure 4A), 10 cases succeeded with manual removal of misregistered outlier slices (Figure 4B-C), 9 cases with manual initialization of the stack alignment (Figure 4D-F), and 2 cases fa...
Saved in:
Published in | NeuroImage (Orlando, Fla.) Vol. 47; p. S72 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
Amsterdam
Elsevier Inc
01.07.2009
Elsevier Limited |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | In the clinical application of the method, 24 cases demonstrated high visual accuracy with no manual intervention (Figure 4A), 10 cases succeeded with manual removal of misregistered outlier slices (Figure 4B-C), 9 cases with manual initialization of the stack alignment (Figure 4D-F), and 2 cases failed to produce a meaningful volume (Figure 4G). |
---|---|