Evaluation of Clinical Fetal Brain MRI Motion Correction for 3D Image Formation

In the clinical application of the method, 24 cases demonstrated high visual accuracy with no manual intervention (Figure 4A), 10 cases succeeded with manual removal of misregistered outlier slices (Figure 4B-C), 9 cases with manual initialization of the stack alignment (Figure 4D-F), and 2 cases fa...

Full description

Saved in:
Bibliographic Details
Published inNeuroImage (Orlando, Fla.) Vol. 47; p. S72
Main Authors Kim, K., Habas, P.A., Rousseau, F., Glenn, O.A., Barkovich, A.J., Studholme, C.
Format Journal Article
LanguageEnglish
Published Amsterdam Elsevier Inc 01.07.2009
Elsevier Limited
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In the clinical application of the method, 24 cases demonstrated high visual accuracy with no manual intervention (Figure 4A), 10 cases succeeded with manual removal of misregistered outlier slices (Figure 4B-C), 9 cases with manual initialization of the stack alignment (Figure 4D-F), and 2 cases failed to produce a meaningful volume (Figure 4G).