The intra‐individual reliability of 1 H‐MRS measurement in the anterior cingulate cortex across 1 year

Magnetic resonance spectroscopy (MRS) is the primary method that can measure the levels of metabolites in the brain in vivo. To achieve its potential in clinical usage, the reliability of the measurement requires further articulation. Although there are many studies that investigate the reliability...

Full description

Saved in:
Bibliographic Details
Published inHuman brain mapping Vol. 45; no. 1; p. e26531
Main Authors Wang, Meng‐Yun, Korbmacher, Max, Eikeland, Rune, Craven, Alexander R., Specht, Karsten
Format Journal Article
LanguageEnglish
Published United States 01.01.2024
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Magnetic resonance spectroscopy (MRS) is the primary method that can measure the levels of metabolites in the brain in vivo. To achieve its potential in clinical usage, the reliability of the measurement requires further articulation. Although there are many studies that investigate the reliability of gamma‐aminobutyric acid (GABA), comparatively few studies have investigated the reliability of other brain metabolites, such as glutamate (Glu), N‐acetyl‐aspartate (NAA), creatine (Cr), phosphocreatine (PCr), or myo‐inositol (mI), which all play a significant role in brain development and functions. In addition, previous studies which predominately used only two measurements (two data points) failed to provide the details of the time effect (e.g., time‐of‐day) on MRS measurement within subjects. Therefore, in this study, MRS data located in the anterior cingulate cortex (ACC) were repeatedly recorded across 1 year leading to at least 25 sessions for each subject with the aim of exploring the variability of other metabolites by using the index coefficient of variability (CV); the smaller the CV, the more reliable the measurements. We found that the metabolites of NAA, tNAA, and tCr showed the smallest CVs (between 1.43% and 4.90%), and the metabolites of Glu, Glx, mI, and tCho showed modest CVs (between 4.26% and 7.89%). Furthermore, we found that the concentration reference of the ratio to water results in smaller CVs compared to the ratio to tCr. In addition, we did not find any time‐of‐day effect on the MRS measurements. Collectively, the results of this study indicate that the MRS measurement is reasonably reliable in quantifying the levels of metabolites.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1065-9471
1097-0193
1097-0193
DOI:10.1002/hbm.26531