Prediction for cardiac prognosis in patients with congestive heart failure by machine learning on dual-isotope myocardial semiconductor SPECT

Abstract Background Dual-isotope (low doze 201TlCl and 123I-β-methyl-P-iodophenyl-pentadecanoic acid (BMIPP)) single photon emission computed tomography (SPECT) is utilized to estimate myocardial damage in patients with congestive heart failure (CHF). However, predictive model construction on the SP...

Full description

Saved in:
Bibliographic Details
Published inEuropean heart journal Vol. 41; no. Supplement_2
Main Authors Shimizu, M, Cho, S, Hara, K, Ohmori, M, Tateishi, R, Kaneda, T, Yamakami, Y, Shimada, H, Manno, T, Isshiki, A, Kimura, S, Fujii, H, Suzuki, M, Nishizaki, M, Sasano, T
Format Journal Article
LanguageEnglish
Published 01.11.2020
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Background Dual-isotope (low doze 201TlCl and 123I-β-methyl-P-iodophenyl-pentadecanoic acid (BMIPP)) single photon emission computed tomography (SPECT) is utilized to estimate myocardial damage in patients with congestive heart failure (CHF). However, predictive model construction on the SPECT for cardiac death by machine learning was not studied. Purpose To elucidate predictive value of machine learning model on dual-isotope SPECT for CHF. Methods We enrolled consecutive 310 patients who admitted with CHF (77.1±3.1 years, 164 males). After initial treatment, they underwent electrocardiography gated SPECT and observed in median 507 days [IQR: 165, 1032]. Multivariate Cox regression analysis for cardiac death was performed, and predictive model was constructed by ROC curve analysis and machine learning (Random Forest and Deep Learning). The accuracies (= [True positive + True negative] / Total) of the prediction models were compared with ROC curve model. Results Thirty-six patients fell into cardiac death. Cox analysis showed Age, left ventricular ejection fraction (LVEF), summed rest score (SRS) of BMIPP, and mismatch score were significant predictors (Hazard ratio: 1.068, 0.970, 1.032, 1.092, P value: <0.001, 0.014, 0.002, <0.001, respectively). ROC curve analysis of them revealed the accuracy of the cut-off value was 0.479–0.773. Conversely, machine learning model demonstrated higher accuracy for cardiac death (Random Forest: 0.895, Deep Learning: 0.935). The top 4 feature importance of the random forest were LVEF (0.299), SRS BMIPP (0.263), Age (0.262), and mismatch score (0.160). Conclusion Machine learning model on SPECT was superior to conventional statistic model for predicting cardiac death in patients with CHF. Funding Acknowledgement Type of funding source: None
ISSN:0195-668X
1522-9645
DOI:10.1093/ehjci/ehaa946.0275