Validity and reliability of a mobile application for velocity–Based training (VBT) in the bench press exercise

The aim of this study was to determine the validityand reliability of Metric VBT mobile application duringthe bench press exercise. The research was attended byfifteen male participants (age 24.2 ± 1.6 years; height 183.8± 7.51 cm; weight 87.8 ± 8.5 kg) with experience in strengthtraining and bench...

Full description

Saved in:
Bibliographic Details
Published inHrvatski športskomedicinski vjesnik Vol. 39; no. 2; pp. 109 - 117
Main Authors Baković, Marijo, Šagovac, Antonio
Format Journal Article
LanguageEnglish
Published 2024
Online AccessGet full text

Cover

Loading…
More Information
Summary:The aim of this study was to determine the validityand reliability of Metric VBT mobile application duringthe bench press exercise. The research was attended byfifteen male participants (age 24.2 ± 1.6 years; height 183.8± 7.51 cm; weight 87.8 ± 8.5 kg) with experience in strengthtraining and bench press exercise for at least two years.Participants were required to perform three maximallyfast concentric repetitions at loads of 45%, 60% and 75%of 1RM in the bench press exercise. Movement velocitywas simultaneously recorded using the Vitruve measuringdevice and the Metric VBT mobile application.Results showed a statistically significant (p < 0.05),very strong correlations of the total number of repetitionsfor the variables of mean velocity (r = 0.93), peak velocity(r = 0.91) and strong correlations for range of motion (r= 0.75). Also, there was a statistically significant (p <0.05) medium to very strong correlation for individualloads in the variables of mean velocity (r = 0,47 to 0,89),peak velocity (r = 0,79 to 0,81) and range of motion (r =0,71 to 0,79). On the other side, reliability for individualrepetitions measured by intraclass correlation coefficient(ICC) indicates in existence of statistically significant (p <0.05) excellent reproducibility of results for mean velocity(ICC = 0,93 to 0,95), peak velocity (ICC = 0,89 to 0,97) andrange of motion (ICC = 0,95 to 0,97). Variation of resultswithin one subject for individual loads measured using thecoefficient of variation (CV) indicates an acceptable level ofvariability (<10%) for mean velocity (CV = 3.91 to 7.09%),peak velocity (CV = 4.90% to 9.41%) and range of motion(CV = 3.07% to 3.91%). Ultimately, the obtained resultssupport the use of the Metric VBT mobile application totrack movement velocity in the bench press exercise. Cilj ovoga rada bio je utvrditi valjanost i pouzdanost mobilne aplikacije Metric VBT u vježbi potisak s ravneklupe. Istraživanju je pristupilo petnaest muških ispitanika(dob 24,2 ± 1,6 godina; visina 183,8 ± 7,51 cm; tjelesna masa87,8 ± 8,5 kg) s iskustvom u treningu s opterećenjem te vježbipotisak s ravne klupe u trajanju od najmanje dvije godine.Od ispitanika se zahtijevalo izvođenje tri maksimalno brzakoncentrična ponavljanja pri opterećenjima od 45%, 60% i75% 1 RM-a u potisku s ravne klupe. Brzina pokreta mjerilase istovremeno pomoću Vitruve mjernog uređaja te mobilneaplikacije Metric VBT.Rezultati su utvrdili statistički značajnu, odnosno vrlojaku korelaciju za sva ponavljanja za varijable srednje (r =0,93) i vršne brzine (r = 0,91) te visoku korelaciju amplitudepokreta (r = 0,75). Također, postoji statistički značajnasrednja do vrlo jaka korelacija za pojedinačna opterećenjau varijablama srednje (r = 0,47 do 0,89) i vršne brzine (r= 0,79 do 0,81) te jaka korelacija amplitude pokreta (r =0,71 do 0,79). S druge strane, pouzdanost za pojedinačnaponavljanja mjerena intraklasnim koeficijentom korelacije(ICC) ukazuje u postojanje statistički značajne (p < 0,05)izvrsne ponovljivosti rezultata za varijable srednje (ICC =0,93 do 0,95) i vršne brzine (ICC = 0,89 do 0,97) te amplitudepokreta (ICC = 0,95 do 0,97). Varijacije rezultata unutarjednog ispitanika za pojedinačna opterećenja mjerenepomoću koeficijenta varijacije (CV) govore o prihvatljivojrazini varijabilnosti (<10%) za varijable srednje (CV =3,91% do 7,09%) i vršne brzine (CV = 4,90% do 9,41%)te amplitude pokreta (CV = 3,07% do 3,91%). Zaključno,utvrđeni rezultati podržavaju uporabu mobilne aplikacijeMetric VBT za praćenje brzine pokreta u vježbi potisak sravne klupe.
ISSN:0354-0766
1848-7742