Evaluation of the dependence of the exposure dose on the attenuation correction in brain PET/CT scans using 18F-FDG

This study examined whether scanning could be performed with minimum dose and minimum exposure to the patient after an attenuation correction. A Hoffman 3D Brain Phantom was used in BIO_40 and D_690 PET/CT scanners, and the CT dose for the equipment was classified as a low dose (minimum dose), mediu...

Full description

Saved in:
Bibliographic Details
Published inJournal of the Korean Physical Society Vol. 64; no. 1; pp. 114 - 121
Main Authors Choi, Eun-Jin, Jeong, Moon-Taeg, Jang, Seong-Joo, Choi, Nam-Gil, Han, Jae-Bok, Yang, Nam-Hee, Dong, Kyung-Rae, Chung, Woon-Kwan, Lee, Yun-Jong, Ryu, Young-Hwan, Choi, Sung-Hyun, Seong, Kyeong-Jeong
Format Journal Article
LanguageEnglish
Published Dordrecht Springer Netherlands 2014
한국물리학회
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:This study examined whether scanning could be performed with minimum dose and minimum exposure to the patient after an attenuation correction. A Hoffman 3D Brain Phantom was used in BIO_40 and D_690 PET/CT scanners, and the CT dose for the equipment was classified as a low dose (minimum dose), medium dose (general dose for scanning) and high dose (dose with use of contrast medium) before obtaining the image at a fixed kilo-voltage-peak (kVp) and milliampere (mA) that were adjusted gradually in 17–20 stages. A PET image was then obtained to perform an attenuation correction based on an attenuation map before analyzing the dose difference. Depending on tube current in the range of 33–190 milliampere-second (mAs) when BIO_40 was used, a significant difference in the effective dose was observed between the minimum and the maximum mAs (p < 0.05). According to a Scheffe post-hoc test, the ratio of the minimum to the maximum of the effective dose was increased by approximately 5.26-fold. Depending on the change in the tube current in the range of 10–200 mA when D_690 was used, a significant difference in the effective dose was observed between the minimum and the maximum of mA (p < 0.05). The Scheffe posthoc test revealed a 20.5-fold difference. In conclusion, because effective exposure dose increases with increasing operating current, it is possible to reduce the exposure limit in a brain scan can be reduced if the CT dose can be minimized for a transmission scan.
Bibliography:G704-000411.2014.64.1.021
ISSN:0374-4884
1976-8524
DOI:10.3938/jkps.64.114