Validation of the continuous glucose monitoring sensor in preterm infants

Objective Recent studies have highlighted the need for improved methods of monitoring glucose control in intensive care to reduce hyperglycaemia, without increasing the risk of hypoglycaemia. Continuous glucose monitoring is increasingly used in children with diabetes, but there are little data rega...

Full description

Saved in:
Bibliographic Details
Published inArchives of disease in childhood. Fetal and neonatal edition Vol. 98; no. 2; pp. F136 - F140
Main Authors Beardsall, K, Vanhaesebrouck, S, Ogilvy-Stuart, A L, Vanhole, C, vanWeissenbruch, M, Midgley, P, Thio, M, Cornette, L, Ossuetta, I, Palmer, C R, Iglesias, I, de Jong, M, Gill, B, de Zegher, F, Dunger, D B
Format Journal Article
LanguageEnglish
Published England BMJ Publishing Group Ltd and Royal College of Paediatrics and Child Health 01.03.2013
BMJ Publishing Group LTD
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective Recent studies have highlighted the need for improved methods of monitoring glucose control in intensive care to reduce hyperglycaemia, without increasing the risk of hypoglycaemia. Continuous glucose monitoring is increasingly used in children with diabetes, but there are little data regarding its use in the preterm infant, particularly at extremes of glucose levels and over prolonged periods. This study aimed to assess the accuracy of the continuous glucose monitoring sensor (CGMS) across the glucose profile, and to determine whether there was any deterioration over a 7 day period. Design Prospectively collected CGMS data from the NIRTURE Trial was compared with the data obtained simultaneously using point of care glucose monitors. Setting An international multicentre randomised controlled trial. Patients One hundred and eighty-eight very low birth weight control infants. Outcome measures Optimal accuracy, performance goals (American Diabetes Association consensus), Bland Altman, Error Grid analyses and accuracy. Results The mean (SD) duration of CGMS recordings was 156.18 (29) h (6.5 days), with a total of 5207 paired glucose levels. CGMS data correlated well with point of care devices (r=0.94), with minimal bias. It met the Clarke Error Grid and Consensus Grid criteria for clinical significance. Accuracy of single readings to detect set thresholds of hypoglycaemia, or hyperglycaemia was poor. There was no deterioration over time from insertion. Conclusions CGMS can provide information on trends in glucose control, and guidance on the need for blood glucose assessment. This highlights the potential use of CGMS in optimising glucose control in preterm infants.
Bibliography:ArticleID:fetalneonatal-2012-301661
PMID:22791467
istex:324D8F8150851FFD1F2A4B34C58B3AB87CE2612F
ark:/67375/NVC-7L062PLW-9
href:fetalneonatal-98-F136.pdf
local:fetalneonatal;98/2/F136
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ObjectType-Undefined-3
ObjectType-Article-2
ObjectType-Feature-1
ISSN:1359-2998
1468-2052
1468-2052
DOI:10.1136/archdischild-2012-301661