Reproducibility of the airway response to an exercise protocol standardized for intensity, duration, and inspired air conditions, in subjects with symptoms suggestive of asthma

Exercise testing to aid diagnosis of exercise-induced bronchoconstriction (EIB) is commonly performed. Reproducibility of the airway response to a standardized exercise protocol has not been reported in subjects being evaluated with mild symptoms suggestive of asthma but without a definite diagnosis...

Full description

Saved in:
Bibliographic Details
Published inRespiratory research Vol. 11; no. 1; p. 120
Main Authors Anderson, Sandra D, Pearlman, David S, Rundell, Kenneth W, Perry, Claire P, Boushey, Homer, Sorkness, Christine A, Nichols, Sara, Weiler, John M
Format Journal Article
LanguageEnglish
Published England BioMed Central Ltd 01.09.2010
BioMed Central
BMC
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Exercise testing to aid diagnosis of exercise-induced bronchoconstriction (EIB) is commonly performed. Reproducibility of the airway response to a standardized exercise protocol has not been reported in subjects being evaluated with mild symptoms suggestive of asthma but without a definite diagnosis. This study examined reproducibility of % fall in FEV1 and area under the FEV1 time curve for 30 minutes in response to two exercise tests performed with the same intensity and duration of exercise, and inspired air conditions. Subjects with mild symptoms of asthma exercised twice within approximately 4 days by running for 8 minutes on a motorized treadmill breathing dry air at an intensity to induce a heart rate between 80-90% predicted maximum; reproducibility of the airway response was expressed as the 95% probability interval. Of 373 subjects challenged twice 161 were positive (≥ 10% fall FEV1 on at least one challenge). The EIB was mild and 77% of subjects had <15% fall on both challenges. Agreement between results was 76.1% with 56.8% (212) negative (< 10% fall FEV1) and 19.3% (72) positive on both challenges. The remaining 23.9% of subjects had only one positive test. The 95% probability interval for reproducibility of the % fall in FEV1 and AUC0-30 min was ± 9.7% and ± 251% for all 278 adults and ± 13.4% and ± 279% for all 95 children. The 95% probability interval for reproducibility of % fall in FEV1 and AUC0-30 min for the 72 subjects with two tests ≥ 10% fall FEV1 was ± 14.6% and ± 373% and for the 34 subjects with two tests ≥ 15% fall FEV1 it was ± 12.2% and ± 411%. Heart rate and estimated ventilation achieved were not significantly different either on the two test days or when one test result was positive and one was negative. Under standardized, well controlled conditions for exercise challenge, the majority of subjects with mild symptoms of asthma demonstrated agreement in test results. Performing two tests may need to be considered when using exercise to exclude or diagnose EIB, when prescribing prophylactic treatment to prevent EIB and when designing protocols for clinical trials.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1465-993X
1465-9921
1465-993X
1465-9921
DOI:10.1186/1465-9921-11-120