A new technique for tear film fluorophotometry

Aim: To develop a reliable and objective non-touch technique for determination of tear volume and tear secretion by means of tear film fluorophotometry. Methods: 10 defined concentrations of sodium fluorescein were given in an artificial chamber and measured by the Fluorotron Master (Coherent Radiat...

Full description

Saved in:
Bibliographic Details
Published inBritish journal of ophthalmology Vol. 86; no. 6; pp. 616 - 619
Main Authors Eter, N, Göbbels, M
Format Journal Article
LanguageEnglish
Published BMA House, Tavistock Square, London, WC1H 9JR BMJ Publishing Group Ltd 01.06.2002
BMJ
BMJ Publishing Group LTD
Copyright 2002 British Journal of Ophthalmology
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Aim: To develop a reliable and objective non-touch technique for determination of tear volume and tear secretion by means of tear film fluorophotometry. Methods: 10 defined concentrations of sodium fluorescein were given in an artificial chamber and measured by the Fluorotron Master (Coherent Radiation Inc). A calibration line was established and the calibration equation was programmed into the Fluorotron Master computer software. In 28 patients (56 eyes) with dry eye symptoms and 15 volunteers (30 eyes) tear volume and tear secretion were then measured directly without taking a tear sample, using the new technique. Results: The values obtained by the Fluorotron Master measuring 10 defined fluorescein concentrations within an artificial chamber are approximately 100 times lower than the actual concentrations. The calibration line led to a calibration equation: y = 36 + 0.01 × X. The mean tear secretion in 56 eyes of patients with dry eye symptoms was 2.48 μl/min, compared to 3.4 μl/min in healthy volunteers. The difference was statistically significant. Average tear volume was 7.0 μl in patients and 7.2 μl in healthy volunteers with no statistically significant difference. Conclusion: The method developed is a simple and reliable non-touch technique without the need for taking a tear sample, which makes the examination faster and more comfortable for the patient.
Bibliography:Correspondence to: Nicole Eter, MD, Department of Ophthalmology, University of Bonn Medical Center, Sigmund-Freud-Strasse 25, D-53105 Bonn, Germany; eter@uni-bonn.de
istex:166D5C6F88ACBDB8FF75D222665D5CA473FB5460
ark:/67375/NVC-2JTKT57G-R
href:bjophthalmol-86-616.pdf
PMID:12034680
local:0860616
SourceType-Other Sources-1
content type line 63
ObjectType-Correspondence-2
ObjectType-Undefined-1
Correspondence to: …Nicole Eter, MD, Department of Ophthalmology, University of Bonn Medical Center, Sigmund-Freud-Strasse 25, D-53105 Bonn, Germany; …eter@uni-bonn.de
ISSN:0007-1161
1468-2079
DOI:10.1136/bjo.86.6.616