Investigation of the stability of one-piece acrylic intraocular lenses in cataract surgery and in combined vitrectomy surgery

Background: To compare the degrees of intraocular lens (IOL) movement between eyes that received a one-piece acrylic IOL and those that received a three-piece acrylic IOL after cataract surgery, and also among eyes that received a one-piece acrylic IOL after a combined vitrectomy surgery for catarac...

Full description

Saved in:
Bibliographic Details
Published inBritish journal of ophthalmology Vol. 90; no. 12; pp. 1519 - 1523
Main Authors Iwase, T, Sugiyama, K
Format Journal Article
LanguageEnglish
Published BMA House, Tavistock Square, London, WC1H 9JR BMJ Publishing Group Ltd 01.12.2006
BMJ
BMJ Publishing Group LTD
BMJ Group
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background: To compare the degrees of intraocular lens (IOL) movement between eyes that received a one-piece acrylic IOL and those that received a three-piece acrylic IOL after cataract surgery, and also among eyes that received a one-piece acrylic IOL after a combined vitrectomy surgery for cataract. Methods: In the first study, we report on 50 patients who were implanted with a one-piece acrylic IOL in one eye and a three-piece acrylic IOL in the contralateral eye for senile cataract. In the second study, we report on 50 patients who were implanted with a one-piece acrylic IOL in combined vitrectomy surgery for cataract and retinal diseases. The degree of IOL decentration and tilt, and anterior chamber depth (ACD) were measured using Scheimpflug video photography at 1 week, 1 month, 3 months and 6 months after surgery in both the studies. The postoperative refractive status was also examined. Results: The mean decentration and tilt showed no marked changes during the follow-up in eyes with either IOL implanted, and no marked differences were noted in either study throughout the follow-up. The ACD did not change after surgery with one-piece IOL implantation, for either the cataract surgery group or the combined surgery group, except for 1 week after surgery in eyes requiring gas tamponade. In contrast, marked shallowing in ACD was observed in the three-piece group after cataract surgery. The spherical equivalent did not change markedly in either study. Conclusions: The one-piece acrylic IOL was stable in the capsular bag, both horizontally and vertically, after cataract surgery, and also after combined surgery.
Bibliography:ark:/67375/NVC-F7G26LB9-P
PMID:16914475
istex:4F1280A2361E856771159EED301A26A88E744802
href:bjophthalmol-90-1519.pdf
local:0901519
Correspondence to: T Iwase Department of Ophthalmology, Toyama Prefectural Central Hospital, 2–2–78 Nishinagae, Toyama City, Toyama 930–8550, Japan; TsuyoshiIwase@aol.com
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-News-1
ObjectType-Feature-3
content type line 23
ISSN:0007-1161
1468-2079
DOI:10.1136/bjo.2006.097766