Changes in anterior segment morphology in response to illumination and after laser iridotomy in Asian eyes: an anterior segment OCT study
Aim:Using the anterior segment optical coherence tomography (AS-OCT) to quantify changes in anterior segment morphology going from light to dark and following laser iridotomy (LI).Methods:Prospective observational study. 17 consecutive subjects without peripheral anterior synechiae undergoing LI wer...
Saved in:
Published in | British journal of ophthalmology Vol. 91; no. 11; pp. 1485 - 1489 |
---|---|
Main Authors | , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
BMA House, Tavistock Square, London, WC1H 9JR
BMJ Publishing Group Ltd
01.11.2007
BMJ BMJ Publishing Group LTD BMJ Group |
Subjects | |
Online Access | Get full text |
ISSN | 0007-1161 1468-2079 |
DOI | 10.1136/bjo.2006.113654 |
Cover
Summary: | Aim:Using the anterior segment optical coherence tomography (AS-OCT) to quantify changes in anterior segment morphology going from light to dark and following laser iridotomy (LI).Methods:Prospective observational study. 17 consecutive subjects without peripheral anterior synechiae undergoing LI were evaluated using gonioscopy and AS-OCT. Angle configuration including angle opening distance (AOD) at 500 microns anterior to the scleral spur, AOD500, trabecular-iris space area up to 750 microns from the scleral spur, TISA750 and the increase in angle opening going from dark to light conditions was determined.Results:Both mean AOD500 and TISA750 increased nearly threefold going from dark to light. Both also significantly increased following LI (p<0.001) as did gonioscopic grading of the angle in all quadrants (p<0.001, McNemar’s test). Angles were more than twice as wide on average in the dark after LI than before LI (p<0.05). Both the mean absolute change and the mean proportionate change in AOD500 and TISA750 when going from light to dark were greater after LI than before (p<0.05).Conclusion:Increased illumination as well as LI resulted in significant widening of the anterior chamber angle. AS-OCT (which does not require a water bath and can be performed with the patient at the slit lamp) identified similar magnitude changes as those previously reported using ultrasound biomicroscopy (UBM). Furthermore, the angle appears to open more both in absolute terms and and proportionate terms in response to illumination after LI. |
---|---|
Bibliography: | ArticleID:bj113654 href:bjophthalmol-91-1485.pdf ark:/67375/NVC-LXHMF142-Q PMID:17504852 local:bjophthalmol;91/11/1485 istex:0FD3179B12EDA8EE2F5B3F987DF2BBF7431D588D ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 ObjectType-Article-2 ObjectType-Undefined-1 ObjectType-Feature-3 content type line 23 |
ISSN: | 0007-1161 1468-2079 |
DOI: | 10.1136/bjo.2006.113654 |