Accuracy and usability of AcuPebble SA100 for automated diagnosis of obstructive sleep apnoea in the home environment setting: an evaluation study

ObjectivesObstructive sleep apnoea (OSA) is a heavily underdiagnosed condition, which can lead to significant multimorbidity. Underdiagnosis is often secondary to limitations in existing diagnostic methods. We conducted a diagnostic accuracy and usability study, to evaluate the efficacy of a novel,...

Full description

Saved in:
Bibliographic Details
Published inBMJ open Vol. 11; no. 12; p. e046803
Main Authors Devani, Nikesh, Pramono, Renard Xaviero Adhi, Imtiaz, Syed Anas, Bowyer, Stuart, Rodriguez-Villegas, Esther, Mandal, Swapna
Format Journal Article
LanguageEnglish
Published England British Medical Journal Publishing Group 21.12.2021
BMJ Publishing Group LTD
BMJ Publishing Group
SeriesOriginal research
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:ObjectivesObstructive sleep apnoea (OSA) is a heavily underdiagnosed condition, which can lead to significant multimorbidity. Underdiagnosis is often secondary to limitations in existing diagnostic methods. We conducted a diagnostic accuracy and usability study, to evaluate the efficacy of a novel, low-cost, small, wearable medical device, AcuPebble_SA100, for automated diagnosis of OSA in the home environment.SettingsPatients were recruited to a standard OSA diagnostic pathway in an UK hospital. They were trained on the use of type-III-cardiorespiratory polygraphy, which they took to use at home. They were also given AcuPebble_SA100; but they were not trained on how to use it.Participants182 consecutive patients had been referred for OSA diagnosis in which 150 successfully completed the study.Primary outcome measuresEfficacy of AcuPebble_SA100 for automated diagnosis of moderate–severe-OSA against cardiorespiratory polygraphy (sensitivity/specificity/likelihood ratios/predictive values) and validation of usability by patients themselves in their home environment.ResultsAfter returning the systems, two expert clinicians, blinded to AcuPebble_SA100’s output, manually scored the cardiorespiratory polygraphy signals to reach a diagnosis. AcuPebble_SA100 generated automated diagnosis corresponding to four, typically followed, diagnostic criteria: Apnoea Hypopnoea Index (AHI) using 3% as criteria for oxygen desaturation; Oxygen Desaturation Index (ODI) for 3% and 4% desaturation criteria and AHI using 4% as desaturation criteria. In all cases, AcuPebble_SA100 matched the experts’ diagnosis with positive and negative likelihood ratios over 10 and below 0.1, respectively. Comparing against the current American Academy of Sleep Medicine’s AHI-based criteria demonstrated 95.33% accuracy (95% CI (90·62% to 98·10%)), 96.84% specificity (95% CI (91·05% to 99·34%)), 92.73% sensitivity (95% CI (82·41% to 97·98%)), 94.4% positive-predictive value (95% CI (84·78% to 98·11%)) and 95.83% negative-predictive value (95% CI (89·94% to 98·34%)). All patients used AcuPebble_SA100 correctly. Over 97% reported a strong preference for AcuPebble_SA100 over cardiorespiratory polygraphy.ConclusionsThese results validate the efficacy of AcuPebble_SA100 as an automated diagnosis alternative to cardiorespiratory polygraphy; also demonstrating that AcuPebble_SA100 can be used by patients without requiring human training/assistance. This opens the doors for more efficient patient pathways for OSA diagnosis.Trial registration numberNCT03544086; ClinicalTrials.gov.
Bibliography:Original research
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ER-V and SM are joint senior authors.
ISSN:2044-6055
2044-6055
DOI:10.1136/bmjopen-2020-046803