Features and predictive value of 6-min walk test outcomes in interstitial lung disease: an observation study using wearable monitors
ObjectivesTo describe 6-min walk test (6MWT) outcomes, and to investigate their correlations with cardiopulmonary and lung function among patients with interstitial lung disease (ILD) which was not limited to idiopathic pulmonary fibrosis.MethodsWe collected patients’ demographic data and obtained m...
Saved in:
Published in | BMJ open Vol. 12; no. 6; p. e055077 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
England
British Medical Journal Publishing Group
15.06.2022
BMJ Publishing Group LTD BMJ Publishing Group |
Series | Original research |
Subjects | |
Online Access | Get full text |
ISSN | 2044-6055 2044-6055 |
DOI | 10.1136/bmjopen-2021-055077 |
Cover
Summary: | ObjectivesTo describe 6-min walk test (6MWT) outcomes, and to investigate their correlations with cardiopulmonary and lung function among patients with interstitial lung disease (ILD) which was not limited to idiopathic pulmonary fibrosis.MethodsWe collected patients’ demographic data and obtained minute-by-minute 6MWT outcomes. Modified Borg scale was employed to assess patients’ dyspnoea, whereas New York Heart Association (NYHA) classification and pulmonary function test were used to evaluate patients’ cardiopulmonary functions.ResultsHeart rate (HR) exhibited a continuous upward trend, while SpO2 exhibited an overall downward with a slight increase at the fifth minute. The SpO2 nadir for 70 patients (9.3%) was lower than 80%. Further, the SpO2 nadir for 78.27% of the participants appeared at the end of the fourth minute. The 6-min walk distance (6MWD) had the strongest correlation with NYHA classification (r=0.82, p<0.01). The ratio of 6MWD to predicted 6MWD was most correlated to forced expiratory volume in the first second (r=0.30, p<0.01) and forced vital capacity (r=0.30, p<0.01). SpO2 at 3 min had the strongest correlation to patients’ diffusing capacity of the lungs for carbon monoxide (r=0.41, p<0.01). We found significant differences in 6MWD (F=2.44, p=0.033), SpO2 change (F=2.58, p=0.025), HR at 0 min (F=2.87, p=0.014), HR at end of 6 min (F=2.58, p=0.025) and HR zenith (F=2.64, p=0.022) between the subtypes of ILD.ConclusionThis observation provided an important evidence regarding oxygen titration. It is better to maintain SpO2 above 88% for 4 min instead of 3 min. SpO2 at the third minute was the most valuable predictor of patients’ lung function. 6MWD and SpO2 changes were more discriminative in subtypes. |
---|---|
Bibliography: | Original research ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ISSN: | 2044-6055 2044-6055 |
DOI: | 10.1136/bmjopen-2021-055077 |