Comparison of two probe designs for determining intraocular oxygen distribution

IntroductionAlterations in intraocular oxygen levels are important contributors to, or indications of, ocular disease. Polarographic electrodes and fibre-optic sensors (optodes) have been used to measure oxygen and to map the distribution of oxygen in animal models and in human eyes. A recent study...

Full description

Saved in:
Bibliographic Details
Published inBritish journal of ophthalmology Vol. 95; no. 1; pp. 118 - 122
Main Authors Park, Young-Hoon, Shui, Ying-Bo, Beebe, David C
Format Journal Article
LanguageEnglish
Published BMA House, Tavistock Square, London, WC1H 9JR BMJ Publishing Group Ltd 01.01.2011
BMJ Publishing Group
BMJ Publishing Group LTD
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:IntroductionAlterations in intraocular oxygen levels are important contributors to, or indications of, ocular disease. Polarographic electrodes and fibre-optic sensors (optodes) have been used to measure oxygen and to map the distribution of oxygen in animal models and in human eyes. A recent study reported the use of a commercial electrode to compare oxygen distribution in the vitreous of patients undergoing vitrectomy related to central retinal vein occlusion, macular hole or preretinal membrane. The results of this study were at variance with previous measures of oxygen distribution in the human vitreous using polarographic or optical sensors. To resolve this discrepancy, the present study compared measurements made in vitro or in animal eyes, using the electrode employed in the previous study or a fibre-optic sensor of a different design.Study designComparative in vitro and in vivo measurements.ResultsIn vitro, the two devices reported similar levels of oxygen, although the electrode consistently detected levels above the calculated values. In rabbit eyes, the electrode had a slow response time and was unable to detect oxygen gradients that were readily measured by the smaller optode. When the electrode was inserted into an eye of similar size to the human eye, the reference thermistor measured the temperature outside the eye, not in the vitreous.ConclusionsThe design of the electrode used in the previous study makes it unsuitable for measurements of oxygen distribution in the eye.
Bibliography:local:bjophthalmol;95/1/118
ark:/67375/NVC-0XK40SM8-V
istex:17D8C29800949DA0A1E6F7B1D3231B43900E767A
ArticleID:bjophthalmol186064
href:bjophthalmol-95-118.pdf
PMID:20870641
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0007-1161
1468-2079
DOI:10.1136/bjo.2010.186064