Transcatheter occlusion of the patent ductus arteriosus with Cook detachable coils

OBJECTIVE: To report initial experience with a new occlusion device for native and residual patent ductus arteriosus. DESIGN: Descriptive study of consecutive non-randomised patients undergoing a new method of patent ductus arteriosus closure with detachable coils. SETTING: Tertiary centres for paed...

Full description

Saved in:
Bibliographic Details
Published inHeart (British Cardiac Society) Vol. 76; no. 6; pp. 531 - 535
Main Authors Tometzki, A. J., Arnold, R., Peart, I., Sreeram, N., Abdulhamed, J. M., Godman, M. J., Patel, R. G., Kitchiner, D. J., Bu'Lock, F. A., Walsh, K. P.
Format Journal Article
LanguageEnglish
Published London BMJ Publishing Group Ltd and British Cardiovascular Society 01.12.1996
BMJ
BMJ Publishing Group LTD
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:OBJECTIVE: To report initial experience with a new occlusion device for native and residual patent ductus arteriosus. DESIGN: Descriptive study of consecutive non-randomised patients undergoing a new method of patent ductus arteriosus closure with detachable coils. SETTING: Tertiary centres for paediatric cardiology. PATIENTS: 71 consecutive patients, aged 1.2-22 years, with a patent ductus arteriosus (PDA) underwent elective transcatheter closure. 45 had native PDAs (group A) with a minimum diameter of 1.0 mm-5.0 mm (median 2.0 mm). A further 26 had undergone one or more previous occlusion attempts (group B). INTERVENTIONS: A total of 133 detachable (Cook) spring coils were successfully implanted in 70 patients. The procedure was performed transvenously in 51 patients, retrograde arterially in 13, and by both routes in a further 6 patients. One 5 mm coil migrated but was successfully retrieved. MAIN OUTCOME MEASURES: In group A colour flow Doppler echocardiography showed that complete occlusion was achieved in 40/45 (89%) at 24 hours, 41/45 (91%) at 1 month, and 44/45 (98%) by 6 months post procedure. Occlusion rates in residual PDAs were 22/25 (88%) occluded at 24 hours, 23/25 (92%) at 1 month, and 24/25 (96%) at 6 months follow up. CONCLUSIONS: Transcatheter occlusion using detachable (Cook) spring coils is a safe and effective alternative to presently available devices. The delivery system allows full retrieval of the coil until a satisfactory position is obtained.
Bibliography:local:heartjnl;76/6/531
istex:3DB8114E0F005914D6A207C5B039D40A0B0B26D2
ark:/67375/NVC-HVV49FL3-L
href:heartjnl-76-531.pdf
PMID:9014804
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1355-6037
1468-201X
DOI:10.1136/hrt.76.6.531