Survey of major complications of intercostal chest drain insertion in the UK
BackgroundFollowing reports from the National Patient Safety Agency of deaths and serious harm from intercostal chest drains (ICD) we conducted a national survey among chest physicians of their experience of harm associated with ICD.MethodsA questionnaire was sent to 198 UK chest physicians at 148 a...
Saved in:
Published in | Postgraduate medical journal Vol. 86; no. 1012; pp. 68 - 72 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
London
The Fellowship of Postgraduate Medicine
01.02.2010
BMJ Publishing Group Oxford University Press |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | BackgroundFollowing reports from the National Patient Safety Agency of deaths and serious harm from intercostal chest drains (ICD) we conducted a national survey among chest physicians of their experience of harm associated with ICD.MethodsA questionnaire was sent to 198 UK chest physicians at 148 acute hospital trusts, enquiring about current practice and any adverse incidents related to chest drains from 2003 to 2008.Results101 of 148 trusts (68%) replied. 67 trusts reported at least one major incident involving ICD insertion. 31 Cases of ICD misplacement were reported with seven deaths. Misplaced drains were inserted in liver (10), peritoneal space (6), heart (5), spleen (5), subclavian vessels (2), colon (1), oesophagus (1) and inferior vena cava (1). 47 cases of serious lung or chest wall injuries with eight deaths and six cases of ICD placement on the wrong side with two deaths were reported. The guidewire was lost in the pleural cavity in three cases. 22 of 101 trusts required written patient consent before ICD insertion. 11 trusts had a training policy. 16 trusts had patient information literature for this procedure. The seniority of doctors permitted to insert ICDs was as follows: 30% any doctor; 27% at least 1 year post qualification; 32% at least 2 years, 11% at least 4 years.Conclusions67% of responding trusts had encountered major complications of ICD. The survey raised concerns about training and consent. The National Patient Safety Agency has made recommendations to address these risks which are also addressed in the 2009 update of the British Thoracic Society Pleural Disease Guideline. |
---|---|
Bibliography: | ArticleID:pmj087759 local:postgradmedj;86/1012/68 Supplementary appendix is published online only at http://pmj.bmj.com/content/vol86/issue1012. istex:15E0B04D797BB83177F6B31BDA3C3B889BD43E55 href:postgradmedj-86-68.pdf ark:/67375/NVC-WFC654KV-0 ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0032-5473 1469-0756 |
DOI: | 10.1136/pgmj.2009.087759 |