Pacing in elderly recurrent fallers with carotid sinus hypersensitivity: a randomised, double-blind, placebo controlled crossover trial

Objectives: While carotid sinus syndrome (CSS) is traditionally defined by the association of carotid sinus hypersensitivity (CSH) with syncope, uncertainty remains over the role, if any, of complex pacing in patients with CSH and unexplained or recurrent falls. We sought to clarify the role of dual...

Full description

Saved in:
Bibliographic Details
Published inHeart (British Cardiac Society) Vol. 95; no. 5; pp. 405 - 409
Main Authors Parry, S W, Steen, N, Bexton, R S, Tynan, M, Kenny, R A
Format Journal Article
LanguageEnglish
Published London BMJ Publishing Group Ltd and British Cardiovascular Society 01.03.2009
BMJ Publishing Group
BMJ Publishing Group LTD
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objectives: While carotid sinus syndrome (CSS) is traditionally defined by the association of carotid sinus hypersensitivity (CSH) with syncope, uncertainty remains over the role, if any, of complex pacing in patients with CSH and unexplained or recurrent falls. We sought to clarify the role of dual chamber pacing in this patient group in the first placebo-controlled study in CSH. Design: Randomised, double-blind, crossover, placebo-controlled trial. Setting: Specialist falls and syncope facility. Patients: Consecutive subjects aged over 55 years with CSH as the sole attributable cause of three or more unexplained falls in the 6 months preceding enrolment. Intervention: Dual-chamber permanent pacing with rate-drop response programming. The pacemaker was switched on (DDD/RDR) or off (ODO (placebo)) for 6 months, then crossed over to the alternate mode for a further 6 months, in randomised, double-blind fashion. Main outcome measure: The primary outcome measure was number of falls in paced and non-paced modes. Results: Twenty-five of 34 subjects (mean 76.8 years (SD 9.0), 27 (79%) female) recruited completed the study. Pacing intervention had no effect on number of falls (4.04 (9.54) in DDD/RDR mode, 3.48 (7.22) in ODO; relative risk of falling in ODO mode 0.82, 95% CI 0.62 to 1.10). Conclusion: Permanent pacing intervention had no effect on fall rates in older patients with CSH. Further work is urgently needed to clarify the role, if any, of complex pacing in this patient group.
Bibliography:ark:/67375/NVC-GX1HRWF4-T
href:heartjnl-95-405.pdf
local:heartjnl;95/5/405
istex:784A62168568A2A0D5BBECF112D59BDF09E01B90
ArticleID:ht153189
PMID:19124530
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-News-1
ObjectType-Feature-3
content type line 23
ISSN:1355-6037
1468-201X
DOI:10.1136/hrt.2008.153189