Comparison of CT colonography, colonoscopy, sigmoidoscopy and faecal occult blood tests for the detection of advanced adenoma in an average risk population

Background and aims:This prospective trial was designed to compare the performance characteristics of five different screening tests in parallel for the detection of advanced colonic neoplasia: CT colonography (CTC), colonoscopy (OC), flexible sigmoidoscopy (FS), faecal immunochemical stool testing...

Full description

Saved in:
Bibliographic Details
Published inGut Vol. 58; no. 2; pp. 241 - 248
Main Authors Graser, A, Stieber, P, Nagel, D, Schäfer, C, Horst, D, Becker, C R, Nikolaou, K, Lottes, A, Geisbüsch, S, Kramer, H, Wagner, A C, Diepolder, H, Schirra, J, Roth, H J, Seidel, D, Göke, B, Reiser, M F, Kolligs, F T
Format Journal Article
LanguageEnglish
Published London BMJ Publishing Group Ltd and British Society of Gastroenterology 01.02.2009
BMJ Publishing Group
BMJ Publishing Group LTD
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background and aims:This prospective trial was designed to compare the performance characteristics of five different screening tests in parallel for the detection of advanced colonic neoplasia: CT colonography (CTC), colonoscopy (OC), flexible sigmoidoscopy (FS), faecal immunochemical stool testing (FIT) and faecal occult blood testing (FOBT).Methods:Average risk adults provided stool specimens for FOBT and FIT, and underwent same-day low-dose 64-multidetector row CTC and OC using segmentally unblinded OC as the standard of reference. Sensitivities and specificities were calculated for each single test, and for combinations of FS and stool tests. CTC radiation exposure was measured, and patient comfort levels and preferences were assessed by questionnaire.Results:221 adenomas were detected in 307 subjects who completed CTC (mean radiation dose, 4.5 mSv) and OC; 269 patients provided stool samples for both FOBT and FIT. Sensitivities of OC, CTC, FS, FIT and FOBT for advanced colonic neoplasia were 100% (95% CI 88.4% to 100%), 96.7% (82.8% to 99.9%), 83.3% (95% CI 65.3% to 94.4%), 32% (95% CI 14.9% to 53.5) and 20% (95% CI 6.8% to 40.7%), respectively. Combination of FS with FOBT or FIT led to no relevant increase in sensitivity. 12 of 45 advanced adenomas were smaller than 10 mm. 46% of patients preferred CTC and 37% preferred OC (p<0.001).Conclusions:High-resolution and low-dose CTC is feasible for colorectal cancer screening and reaches sensitivities comparable with OC for polyps >5 mm. For patients who refuse full bowel preparation and OC or CTC, FS should be preferred over stool tests. However, in cases where stool tests are performed, FIT should be recommended rather than FOBT.
Bibliography:istex:6B461563BACE230522BF65F5DD8816428E6381A3
local:gutjnl;58/2/241
href:gutjnl-58-241.pdf
PMID:18852257
ark:/67375/NVC-PJB0QBGK-9
ArticleID:gt156448
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
ISSN:0017-5749
1468-3288
1468-3288
DOI:10.1136/gut.2008.156448