Characteristics of hydrophobicity loss on silicone rubber surface during a dynamic drop test with direct current voltage application

Dynamic drop test for studying the temporal lowering of hydrophobicity on the surface of silicone rubber with direct current voltage application was carried out. In this study, we evaluated the influence of the temporal lowering of hydrophobicity under various conductivities and dropping rates for w...

Full description

Saved in:
Bibliographic Details
Published inNanoscale research letters Vol. 7; no. 1; p. 4
Main Authors Seo, Yuya, Oshikawa, Norihito, Miyake, Takuma, Sakoda, Tatsuya, Anjiki, Tomikazu
Format Journal Article
LanguageEnglish
Published New York Springer New York 05.01.2012
BioMed Central Ltd
Springer
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Dynamic drop test for studying the temporal lowering of hydrophobicity on the surface of silicone rubber with direct current voltage application was carried out. In this study, we evaluated the influence of the temporal lowering of hydrophobicity under various conductivities and dropping rates for water droplets. As a result, it was found that the dropping rate and the conductivity of water droplets greatly influenced the hydrophobicity loss time on the surface of silicone rubber.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1556-276X
1931-7573
1556-276X
DOI:10.1186/1556-276X-7-4