Does the Integration of Personalized Ultrasound Change Patient Management in Critical Care Medicine? Observational Trials

Objective. To test the influence of personalized ultrasound (PersUS) on patient management in critical care. Design of the Study. Prospective, observational, and critical care setting. Four substudies compared PersUS and mobile ultrasound, work distribution, and diagnostic and procedural quality. Pa...

Full description

Saved in:
Bibliographic Details
Published inEmergency Medicine International Vol. 2013; no. 2013; pp. 203 - 210
Main Authors Breitkreutz, Raoul, Campo delľ Orto, Marco, Hamm, Christian Wilhelm, Cuca, Colleen, Zechner, Peter M., Stenger, Tanja, Walcher, Felix, Seeger, Florian Hartmut
Format Journal Article
LanguageEnglish
Published Cairo, Egypt Hindawi Limiteds 01.01.2013
Hindawi Puplishing Corporation
Hindawi Publishing Corporation
John Wiley & Sons, Inc
Wiley
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective. To test the influence of personalized ultrasound (PersUS) on patient management in critical care. Design of the Study. Prospective, observational, and critical care setting. Four substudies compared PersUS and mobile ultrasound, work distribution, and diagnostic and procedural quality. Patients and Interventions. 640 patient ultrasound exams including 548 focused diagnostic exams and 92 interventional procedures. Main Outcome Measures. Number of studies, physician’s judgement of feasibility, time of usage per patient, and referrals to echo lab. Results. Randomized availability of PersUS increased its application in ICU work shifts more than twofold from 33 to 68 exams mainly for detection and therapy of effusions. Diagnostic and procedural quality was rated as excellent/very good in PersUS-guided puncture in 95% of cases. Integrating PersUS within an initial physical examination of 48 randomized cases in an emergency department, PersUS extended the examination time by 100 seconds. Interestingly, PersUS integration into 53 randomized regular ward rounds of 1007 patients significantly reduced average contact time per patient by 103 seconds from 8.9 to 7.2 minutes. Moreover, it lowered the patient referral rate to an echo lab from 20% to 2% within the study population. Conclusions. We propose the development of novel ultrasound-based clinical pathways by integration of PersUS.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Academic Editor: Tobias Lindner
ISSN:2090-2840
2090-2859
DOI:10.1155/2013/946059