Polyelectrolyte-Coated Gold Magnetic Nanoparticles for Immunoassay Development: Toward Point of Care Diagnostics for Syphilis Screening

Immediate response for disease control relies on simple, inexpensive, and sensitive diagnostic tests, highly sought after for timely and accurate test of various diseases, including infectious diseases. Composite Fe3O4/Au nanoparticles have attracted considerable interest in diagnostic applications...

Full description

Saved in:
Bibliographic Details
Published inAnalytical chemistry (Washington) Vol. 85; no. 14; pp. 6688 - 6695
Main Authors Yang, Dong, Ma, Jianzhong, Zhang, Qinlu, Li, Ningning, Yang, Jiangcun, Raju, Paul Ananda, Peng, Mingli, Luo, Yanling, Hui, Wenli, Chen, Chao, Cui, Yali
Format Journal Article
LanguageEnglish
Published United States American Chemical Society 16.07.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Immediate response for disease control relies on simple, inexpensive, and sensitive diagnostic tests, highly sought after for timely and accurate test of various diseases, including infectious diseases. Composite Fe3O4/Au nanoparticles have attracted considerable interest in diagnostic applications due to their unique physical and chemical properties. Here, we developed a simple coating procedure for gold magnetic nanoparticles (GMNs) with poly(acrylic acid) (PAA). PAA-coated GMNs (PGMNs) were stable and monodispersed and characterized by Fourier transform-infrared spectroscopy (FT-IR), transmission electron microscopy, UV–visible scanning spectrophotometry, thermogravimetric analysis, and Zetasizer methodologies. For diagnostic application, we established a novel lateral flow immunoassay (LFIA) strip test system where recombinant Treponema pallidum antigens (r-Tp) were conjugated with PGMNs to construct a particle probe for detection of anti-Tp antibodies. Intriguingly, the particle probes specifically identified Tp antibodies with a detection limitation as low as 1 national clinical unit/mL (NCU/mL). An ample pool of 1020 sera samples from three independent hospitals were obtained to assess our PGMNs-based LFIA strips, which exhibited substantially high values of sensitivity and specificity for all clinical tests (higher than 97%) and, therefore, proved to be a suitable approach for syphilis screening at a point-of-care test manner.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:0003-2700
1520-6882
DOI:10.1021/ac400517e