Compound-Specific Chlorine Isotope Analysis: A Comparison of Gas Chromatography/Isotope Ratio Mass Spectrometry and Gas Chromatography/Quadrupole Mass Spectrometry Methods in an Interlaboratory Study

Chlorine isotope analysis of chlorinated hydrocarbons like trichloroethylene (TCE) is of emerging demand because these species are important environmental pollutants. Continuous flow analysis of noncombusted TCE molecules, either by gas chromatography/isotope ratio mass spectrometry (GC/IRMS) or by...

Full description

Saved in:
Bibliographic Details
Published inAnalytical chemistry (Washington) Vol. 83; no. 20; pp. 7624 - 7634
Main Authors Bernstein, Anat, Shouakar-Stash, Orfan, Ebert, Karin, Laskov, Christine, Hunkeler, Daniel, Jeannottat, Simon, Sakaguchi-Söder, Kaori, Laaks, Jens, Jochmann, Maik A, Cretnik, Stefan, Jager, Johannes, Haderlein, Stefan B, Schmidt, Torsten C, Aravena, Ramon, Elsner, Martin
Format Journal Article
LanguageEnglish
Published Washington, DC American Chemical Society 15.10.2011
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Chlorine isotope analysis of chlorinated hydrocarbons like trichloroethylene (TCE) is of emerging demand because these species are important environmental pollutants. Continuous flow analysis of noncombusted TCE molecules, either by gas chromatography/isotope ratio mass spectrometry (GC/IRMS) or by GC/quadrupole mass spectrometry (GC/qMS), was recently brought forward as innovative analytical solution. Despite early implementations, a benchmark for routine applications has been missing. This study systematically compared the performance of GC/qMS versus GC/IRMS in six laboratories involving eight different instruments (GC/IRMS, Isoprime and Thermo MAT-253; GC/qMS, Agilent 5973N, two Agilent 5975C, two Thermo DSQII, and one Thermo DSQI). Calibrations of 37Cl/35Cl instrument data against the international SMOC scale (Standard Mean Ocean Chloride) deviated between instruments and over time. Therefore, at least two calibration standards are required to obtain true differences between samples. Amount dependency of δ37Cl was pronounced for some instruments, but could be eliminated by corrections, or by adjusting amplitudes of standards and samples. Precision decreased in the order GC/IRMS (1σ ≈ 0.1‰), to GC/qMS (1σ ≈ 0.2–0.5‰ for Agilent GC/qMS and 1σ ≈ 0.2–0.9‰ for Thermo GC/qMS). Nonetheless, δ37Cl values between laboratories showed good agreement when the same external standards were used. These results lend confidence to the methods and may serve as a benchmark for future applications.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0003-2700
1520-6882
DOI:10.1021/ac200516c