Monitoring of pH and PCO2 in children using the Paratrend 7 in a peripheral vein

To determine the accuracy of the Paratrend 7 monitor inserted into a peripheral vein in providing continuous measurements of PCO2 and pH in children with respiratory failure. In a prospective, case series at a University based PICU in a tertiary referral hospital and following informed consent, the...

Full description

Saved in:
Bibliographic Details
Published inCanadian journal of anesthesia Vol. 45; no. 1; p. 81
Main Authors Tobias, J D, Meyer, Jr, D J, Helikson, M A
Format Journal Article
LanguageEnglish
Published United States 01.01.1998
Subjects
Online AccessGet full text

Cover

Loading…
Abstract To determine the accuracy of the Paratrend 7 monitor inserted into a peripheral vein in providing continuous measurements of PCO2 and pH in children with respiratory failure. In a prospective, case series at a University based PICU in a tertiary referral hospital and following informed consent, the Paratrend 7 intra-arterial blood gas monitoring system was inserted through a peripheral intravenous cannula. When clinically indicated, an arterial blood gas (ABG) was obtained. The values of pH and PCO2 from the Paratrend 7 and the ABG were compared using linear regression analysis and Bland-Altman analysis. Seventeen ABGs were obtained in the 4 patients. PaCO2 ranged from 29 to 51 mmHg and the pH values from 7.16 to 7.50. Linear regression analysis for the: Paratrend 7 pH vs the ABG pH resulted in an r = 0.9678 and an r2 = 0.9367 (P < 0.0001). Linear regression analysis for the Paratrend 7 CO2 vs ABG CO2 resulted in an r = 0.8273 and an r2 = 0.6845 (P = 0.01). Using a Bland and Altman analysis, the bias +/- precision of the PCO2 values was 3 +/- 1.4 and 0.036 +/- 0.02 for the pH values. The pH and PCO2 values obtained from the Paratrend 7 monitor provide a clinically acceptable correlation with arterial values.
AbstractList To determine the accuracy of the Paratrend 7 monitor inserted into a peripheral vein in providing continuous measurements of PCO2 and pH in children with respiratory failure. In a prospective, case series at a University based PICU in a tertiary referral hospital and following informed consent, the Paratrend 7 intra-arterial blood gas monitoring system was inserted through a peripheral intravenous cannula. When clinically indicated, an arterial blood gas (ABG) was obtained. The values of pH and PCO2 from the Paratrend 7 and the ABG were compared using linear regression analysis and Bland-Altman analysis. Seventeen ABGs were obtained in the 4 patients. PaCO2 ranged from 29 to 51 mmHg and the pH values from 7.16 to 7.50. Linear regression analysis for the: Paratrend 7 pH vs the ABG pH resulted in an r = 0.9678 and an r2 = 0.9367 (P < 0.0001). Linear regression analysis for the Paratrend 7 CO2 vs ABG CO2 resulted in an r = 0.8273 and an r2 = 0.6845 (P = 0.01). Using a Bland and Altman analysis, the bias +/- precision of the PCO2 values was 3 +/- 1.4 and 0.036 +/- 0.02 for the pH values. The pH and PCO2 values obtained from the Paratrend 7 monitor provide a clinically acceptable correlation with arterial values.
Author Tobias, J D
Meyer, Jr, D J
Helikson, M A
Author_xml – sequence: 1
  givenname: J D
  surname: Tobias
  fullname: Tobias, J D
  organization: Department of Child Health, University of Missouri, Columbia 65212, USA
– sequence: 2
  givenname: D J
  surname: Meyer, Jr
  fullname: Meyer, Jr, D J
– sequence: 3
  givenname: M A
  surname: Helikson
  fullname: Helikson, M A
BackLink https://www.ncbi.nlm.nih.gov/pubmed/9466035$$D View this record in MEDLINE/PubMed
BookMark eNqFjr0OgjAURjtgEH8eweS-AEkFqTgTDYuRwcGNVHuRGrg0LZj49krC7vQl55zhWzCPOkKPBTyNo1Bs-W3OFs69OOepSFKf-YedEDxOAlacO9J9ZzU9oavA5CBJQZFdItAEj1o3yiLB4MagrxEKaWX_Qwr2YyHBoNWmRisbeKOmFZtVsnG4nnbJNqfjNctDM9xbVKWxupX2U04P4n_-C88aPAY
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
MEDLINE with Full Text
Medline Complete
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
ExternalDocumentID 9466035
Genre Comparative Study
Journal Article
GroupedDBID ---
-EM
.55
.GJ
06D
0R~
0VY
199
2.D
203
29B
29~
2JN
2KG
2KM
2LR
2WC
30V
3O-
3V.
4.4
406
408
40D
40E
53G
5GY
5RE
5VS
67Z
6J9
6PF
7RV
7X7
88E
8AO
8FI
8FJ
8FQ
8TC
8UJ
95.
96X
AAAVM
AABHQ
AACDK
AAHNG
AAIAL
AAJBT
AAJKR
AANXM
AANZL
AARHV
AARTL
AASML
AATNV
AATVU
AAUYE
AAWTL
AAYIU
AAYQN
AAYTO
AAYZH
AAZMS
ABAKF
ABDZT
ABECU
ABFTV
ABHLI
ABIPD
ABJOX
ABKCH
ABLJU
ABMQK
ABOCM
ABPLI
ABQBU
ABSXP
ABTEG
ABTKH
ABTMW
ABULA
ABUWG
ABUWZ
ABXPI
ACAOD
ACBXY
ACDTI
ACGFO
ACGFS
ACHSB
ACHVE
ACHXU
ACIHN
ACIPQ
ACKNC
ACMDZ
ACMLO
ACOKC
ACZOJ
ADBBV
ADHIR
ADINQ
ADKNI
ADKPE
ADTPH
ADURQ
ADYFF
ADZKW
AEAQA
AEBTG
AEGNC
AEJHL
AEJRE
AEKMD
AEMSY
AEOHA
AEPYU
AESKC
AETCA
AEVLU
AEXYK
AFDYV
AFJLC
AFKRA
AFLOW
AFQWF
AFWTZ
AFZKB
AGDGC
AGMZJ
AGQEE
AGQMX
AGRTI
AGWZB
AGYKE
AHAVH
AHBYD
AHIZS
AHMBA
AHSBF
AHYZX
AIAKS
AIGIU
AIIXL
AILAN
AITGF
AJBLW
AJRNO
AKMHD
ALIPV
ALMA_UNASSIGNED_HOLDINGS
AMKLP
AMXSW
AMYLF
ANMIH
AOCGG
ARMRJ
AXYYD
AYCSE
AZFZN
BAWUL
BENPR
BGNMA
BKEYQ
BPHCQ
BVXVI
CAG
CCPQU
CGR
COF
CSCUP
CUY
CVF
DDRTE
DIK
DNIVK
DPUIP
DWQXO
E3Z
EBLON
EBS
ECM
EIF
EIOEI
EJD
EMOBN
ESBYG
EX3
F5P
FEDTE
FERAY
FFXSO
FIGPU
FINBP
FNLPD
FRRFC
FSGXE
FYUFA
GGCAI
GGRSB
GJIRD
GNWQR
GQ6
GQ7
GX1
H13
HF~
HG6
HMCUK
HMJXF
HRMNR
HVGLF
HZ~
IKXTQ
IMOTQ
ITM
IWAJR
IXC
I~X
J-C
J0Z
J5H
JBSCW
JZLTJ
KOV
LLZTM
M1P
M4Y
MA-
N2Q
N9A
NAPCQ
NPM
NPVJJ
NQJWS
NU0
O9-
O93
O9I
O9J
OK1
P2P
P9S
PQQKQ
PROAC
PSQYO
PT4
Q2X
R9I
ROL
RSV
S1Z
S27
S37
S3B
SDH
SHX
SISQX
SJYHP
SMD
SNE
SNPRN
SNX
SOHCF
SOJ
SPISZ
SRMVM
SSLCW
SSXJD
STPWE
SV3
SZ9
SZN
T13
TCE
TR2
TSG
TUC
U2A
U9L
UG4
UKHRP
UOJIU
UTJUX
UZXMN
VC2
VFIZW
W48
WK8
WOW
X7M
Z45
Z7U
Z81
Z82
Z83
Z87
ZGI
ZMTXR
ZOVNA
ID FETCH-pubmed_primary_94660353
ISSN 0832-610X
IngestDate Tue Oct 15 23:19:34 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 1
Language English
LinkModel OpenURL
MergedId FETCHMERGED-pubmed_primary_94660353
PMID 9466035
ParticipantIDs pubmed_primary_9466035
PublicationCentury 1900
PublicationDate 1998-Jan
PublicationDateYYYYMMDD 1998-01-01
PublicationDate_xml – month: 01
  year: 1998
  text: 1998-Jan
PublicationDecade 1990
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Canadian journal of anesthesia
PublicationTitleAlternate Can J Anaesth
PublicationYear 1998
SSID ssj0008658
Score 3.071908
Snippet To determine the accuracy of the Paratrend 7 monitor inserted into a peripheral vein in providing continuous measurements of PCO2 and pH in children with...
SourceID pubmed
SourceType Index Database
StartPage 81
SubjectTerms Adolescent
Arteries
Bias
Carbon Dioxide - blood
Catheterization, Peripheral - instrumentation
Catheters, Indwelling
Child
Child, Preschool
Critical Care
Female
Humans
Hydrogen-Ion Concentration
Infant
Linear Models
Male
Monitoring, Physiologic - instrumentation
Prospective Studies
Respiratory Insufficiency - blood
Sensitivity and Specificity
Veins
Title Monitoring of pH and PCO2 in children using the Paratrend 7 in a peripheral vein
URI https://www.ncbi.nlm.nih.gov/pubmed/9466035
Volume 45
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnZ3bS8MwFMaDGwh7EUWHt8l58G1UurZp46PMSxlM9zChb6NZMyhoN3YD_es9ubSZY4L6EkobQuivPU3S830h5NqnQUa5VPRQL3CCaNxxmOcLh43dkMtPoFBC4f5zGL8GvYQmdqtDpS5Z8pvx505dyX-o4jnkKlWyfyBbNYon8Bj5YomEsfwVY_1CzsvE5Vin_ndfPLmKUcm0V4tSEjWQPt8yCbYdyRqpNC3Ola_AW3stjAf3tm3BhrdEinER21nkVSwfTnluJGE2d7gvPvSD0FPlvf31hB-5vJT0980yamY1eNWSg4lMvodzTjfZDKPaFfLb46Jjot6SZQPH7F3xkM72rvYq2bK8NldqpOZ3ZJrmU2LTdlio9lytutAg-6b61sRADRCGh-TAjOzhTmM6InuiOCYDiwimE5jFgIhAIoK8gBIRKESAtxYqRBDJGilYRCARnZDW48OwGzu6E6OZdgsZmd75TVIvpoU4JRAJNxQ0yrKQucGEuinFaQ5jnN4yHBx2-Blp7m7j_KcLF6RhOV2S-nK-Ei0cLC35lbp7X7QmGL4
link.rule.ids 315,786,790
linkProvider Geneva Foundation for Medical Education and Research
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Monitoring+of+pH+and+PCO2+in+children+using+the+Paratrend+7+in+a+peripheral+vein&rft.jtitle=Canadian+journal+of+anesthesia&rft.au=Tobias%2C+J+D&rft.au=Meyer%2C+Jr%2C+D+J&rft.au=Helikson%2C+M+A&rft.date=1998-01-01&rft.issn=0832-610X&rft.volume=45&rft.issue=1&rft.spage=81&rft_id=info%3Apmid%2F9466035&rft.externalDocID=9466035
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0832-610X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0832-610X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0832-610X&client=summon