Impact of 68 Ga-PSMA-PET imaging on target volume definition and guidelines in radiation oncology - a patterns of failure analysis in patients with primary diagnosis of prostate cancer

Ga-PSMA-PET-imaging has proven to be a highly sensitive and specific diagnostic element for patients with prostate cancer (PC). Does the standard clinical target volume (CTV) cover the majority of Ga-PSMA-PET detected lymph nodes (LNs) in a primary setting? 25 out of 159 patients with primary PC who...

Full description

Saved in:
Bibliographic Details
Published inRadiation oncology (London, England) Vol. 13; no. 1; p. 36
Main Authors Schiller, K, Devecka, M, Maurer, T, Eiber, M, Gschwend, J, Schwaiger, M, Combs, S E, Habl, G
Format Journal Article
LanguageEnglish
Published England 01.03.2018
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Ga-PSMA-PET-imaging has proven to be a highly sensitive and specific diagnostic element for patients with prostate cancer (PC). Does the standard clinical target volume (CTV) cover the majority of Ga-PSMA-PET detected lymph nodes (LNs) in a primary setting? 25 out of 159 patients with primary PC who underwent Ga-PSMA-PET-imaging were analyzed in the process of this study. These 25 high-risk patients had a total of 126 LNs with positive Ga-PSMA-ligand uptake. A standard CTV according to the 'Radiation Therapy Oncology Group' consensus was delineated and LNs were judged whether they were in- or outside of this target volume. With a Pearson correlation we additionally evaluated whether the Gleason score, the prostate-specific antigen (PSA) value or the risk according to the Roach formula correlate with a higher chance of LNs being outside of the CTV in uncommon LN locations. 81 (64.3%) of 126 LNs were covered by the CTV with a complete coverage of all positive LNs inside the respective radiation volume in 11 of 25 patients (44%). LNs that were not covered by the CTV included (para-aortic,) common-iliac, pre-sacral, obturatoric, para-rectal, para-vesical and pre-acetabular locations. In a statistical analysis neither the Gleason score, nor the PSA value, nor the calculated risk with the Roach formula correlated with LNs being inside or outside of the CTV in this patient group. Ga-PSMA-PET-imaging proves to be a valuable asset for patients and physicians for primary diagnosis and treatment planning. In our study, trusting the RTOG consensus for CTV delineation would have led to up to 35.7% of all LNs not to be included in the clinical radiation volume, which might have resulted in insufficient radiation dose coverage.
AbstractList Ga-PSMA-PET-imaging has proven to be a highly sensitive and specific diagnostic element for patients with prostate cancer (PC). Does the standard clinical target volume (CTV) cover the majority of Ga-PSMA-PET detected lymph nodes (LNs) in a primary setting? 25 out of 159 patients with primary PC who underwent Ga-PSMA-PET-imaging were analyzed in the process of this study. These 25 high-risk patients had a total of 126 LNs with positive Ga-PSMA-ligand uptake. A standard CTV according to the 'Radiation Therapy Oncology Group' consensus was delineated and LNs were judged whether they were in- or outside of this target volume. With a Pearson correlation we additionally evaluated whether the Gleason score, the prostate-specific antigen (PSA) value or the risk according to the Roach formula correlate with a higher chance of LNs being outside of the CTV in uncommon LN locations. 81 (64.3%) of 126 LNs were covered by the CTV with a complete coverage of all positive LNs inside the respective radiation volume in 11 of 25 patients (44%). LNs that were not covered by the CTV included (para-aortic,) common-iliac, pre-sacral, obturatoric, para-rectal, para-vesical and pre-acetabular locations. In a statistical analysis neither the Gleason score, nor the PSA value, nor the calculated risk with the Roach formula correlated with LNs being inside or outside of the CTV in this patient group. Ga-PSMA-PET-imaging proves to be a valuable asset for patients and physicians for primary diagnosis and treatment planning. In our study, trusting the RTOG consensus for CTV delineation would have led to up to 35.7% of all LNs not to be included in the clinical radiation volume, which might have resulted in insufficient radiation dose coverage.
Author Eiber, M
Devecka, M
Combs, S E
Gschwend, J
Schwaiger, M
Schiller, K
Habl, G
Maurer, T
Author_xml – sequence: 1
  givenname: K
  orcidid: 0000-0001-9371-0391
  surname: Schiller
  fullname: Schiller, K
  email: kilian.schiller@mri.tum.de
  organization: Department of Radiation Oncology, Technical University of Munich (TUM), Munich, Germany. kilian.schiller@mri.tum.de
– sequence: 2
  givenname: M
  surname: Devecka
  fullname: Devecka, M
  organization: Department of Radiation Oncology, Technical University of Munich (TUM), Munich, Germany
– sequence: 3
  givenname: T
  surname: Maurer
  fullname: Maurer, T
  organization: Department of Urology, Technical University Munich (TUM), Munich, Germany
– sequence: 4
  givenname: M
  surname: Eiber
  fullname: Eiber, M
  organization: Deutsches Konsortium für Translationale Krebsforschung (DKTK) Partner Site Munich, Heidelberg, Germany
– sequence: 5
  givenname: J
  surname: Gschwend
  fullname: Gschwend, J
  organization: Department of Urology, Technical University Munich (TUM), Munich, Germany
– sequence: 6
  givenname: M
  surname: Schwaiger
  fullname: Schwaiger, M
  organization: Deutsches Konsortium für Translationale Krebsforschung (DKTK) Partner Site Munich, Heidelberg, Germany
– sequence: 7
  givenname: S E
  surname: Combs
  fullname: Combs, S E
  organization: Deutsches Konsortium für Translationale Krebsforschung (DKTK) Partner Site Munich, Heidelberg, Germany
– sequence: 8
  givenname: G
  surname: Habl
  fullname: Habl, G
  organization: Institute of Innovative Radiotherapy (iRT), Department of Radiation Sciences (DRS), Helmholtz Zentrum, Munich, Germany
BackLink https://www.ncbi.nlm.nih.gov/pubmed/29490670$$D View this record in MEDLINE/PubMed
BookMark eNqFj01OwzAQhS0Eoi1wBTQXiOTS0DRLhMrPAqkSXbCrhmRiBjljy3ZAuRnHw63KmtUsvve9p5mpU3FCJ2o6r8pVUc2rt4maxfipdXm70PW5mtzUZa2XlZ6qn-feY5PAdbBcwSMWm9eXu2Kz3gL3aFgMOIGEwVCCL2eHnqCljoUTZ4DSghm4JctCEVggYMt4YE4aZ50ZoQAEjylRkLjf6ZDtECjLaMfIBy1zJkkRvjl9gA95PIyQq4y4fSRrPriYMBE0KA2FS3XWoY10dbwX6vphvb1_Kvzw3lO7O3bs_l5d_Bv4Beo_Y-4
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
MEDLINE with Full Text
Medline Complete
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1748-717X
ExternalDocumentID 29490670
Genre Journal Article
GroupedDBID ---
-A0
0R~
123
29P
2WC
3V.
53G
5VS
7X7
88E
8FI
8FJ
AAFWJ
AAJSJ
AAWTL
ABDBF
ABUWG
ACGFS
ACRMQ
ADBBV
ADINQ
ADRAZ
ADUKV
AENEX
AFKRA
AFPKN
AHBYD
AHYZX
ALIPV
ALMA_UNASSIGNED_HOLDINGS
AMKLP
AOIJS
BAWUL
BCNDV
BENPR
BFQNJ
BMC
BPHCQ
BVXVI
C24
C6C
CCPQU
CGR
CS3
CUY
CVF
DIK
E3Z
EBD
EBLON
EBS
ECM
EIF
EJD
ESX
F5P
FYUFA
GROUPED_DOAJ
H13
HMCUK
HYE
I-F
IAO
IHR
INH
INR
ITC
KQ8
M1P
M48
M~E
NPM
O5R
O5S
OK1
P2P
PGMZT
PIMPY
PQQKQ
PROAC
PSQYO
RBZ
RNS
ROL
RPM
RSV
SMD
SOJ
TUS
UKHRP
WOQ
WOW
~8M
ID FETCH-pubmed_primary_294906703
IngestDate Sat Nov 02 12:20:37 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 1
Language English
LinkModel OpenURL
MergedId FETCHMERGED-pubmed_primary_294906703
ORCID 0000-0001-9371-0391
PMID 29490670
ParticipantIDs pubmed_primary_29490670
PublicationCentury 2000
PublicationDate 2018-Mar-01
PublicationDateYYYYMMDD 2018-03-01
PublicationDate_xml – month: 03
  year: 2018
  text: 2018-Mar-01
  day: 01
PublicationDecade 2010
PublicationPlace England
PublicationPlace_xml – name: England
PublicationTitle Radiation oncology (London, England)
PublicationTitleAlternate Radiat Oncol
PublicationYear 2018
SSID ssj0045309
Score 4.1456313
Snippet Ga-PSMA-PET-imaging has proven to be a highly sensitive and specific diagnostic element for patients with prostate cancer (PC). Does the standard clinical...
SourceID pubmed
SourceType Index Database
StartPage 36
SubjectTerms Aged
Aged, 80 and over
Edetic Acid - analogs & derivatives
Gallium Isotopes
Gallium Radioisotopes
Humans
Lymphatic Metastasis - diagnostic imaging
Male
Middle Aged
Oligopeptides
Positron Emission Tomography Computed Tomography - methods
Positron Emission Tomography Computed Tomography - standards
Prostatic Neoplasms - diagnostic imaging
Prostatic Neoplasms - radiotherapy
Radiation Oncology - methods
Radiation Oncology - standards
Radiotherapy Planning, Computer-Assisted - methods
Title Impact of 68 Ga-PSMA-PET imaging on target volume definition and guidelines in radiation oncology - a patterns of failure analysis in patients with primary diagnosis of prostate cancer
URI https://www.ncbi.nlm.nih.gov/pubmed/29490670
Volume 13
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnZ3LSsNAFIaHWkHciPd7OQt3YUrbTGKyLFIvhYrQCt2VSTKRoKZF2o2v4cv4eJ7TmUmqVlA3oSSThOR8TOZM__MPY2fSC4XvqZAnmFBzEbcUx3Gz4mEUp57niyQ6p9rh3q1_fS-6Q29YqbwtqJZm06gevy6tK_lPVHEfxpWqZP8Q2eKiuAN_Y3xxixHG7a9ifFOUOPqBcyX5Xb_X5nedgZM9m8WHckdLvR3dCzmJSrM8m1oN8sOMXK5I-T6vayGfAj2CzGPtzcQdSdarNGs413ykMnvSfzkYL5PSmtXUyU2MfUWiNXza7mRCtSU4qiWNWWz0wNYV_PtNl60ysjBj0acCdFPAWEzSkvgpfpSf5nd7cmYW6y6U4B0SyJSNzHRHMyj1XnWlu-hzEXBMQoef-nD3G6u6Q9buKgssTJ7nMLRCEVKJUvkZLMSJ9tAKW3GbXpWtttvdftd-3oXnNshq1rb6ko7MhyWDTbZh8gloazi2WEXl22ytZxQTO-xdMwLjFPwAFhgBwwiMc9CMgH5KKBkBfPFQMgJZDgUjYMMFHCRYRug-hhGwjNBplhEgRsAwAgUjdJplBDQju6x22RlcXHP93CNzzsi-EXePVfNxrg4YNJoSM-pWIKVKhHADzJFSL47SJBLYtiEO2f4PFzn68cgxWy-5OGHV6ctMneLAcBrVTKg-AIFCc9M
link.rule.ids 315,783,787
linkProvider Springer Nature
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Impact+of+68+Ga-PSMA-PET+imaging+on+target+volume+definition+and+guidelines+in+radiation+oncology+-+a+patterns+of+failure+analysis+in+patients+with+primary+diagnosis+of+prostate+cancer&rft.jtitle=Radiation+oncology+%28London%2C+England%29&rft.au=Schiller%2C+K&rft.au=Devecka%2C+M&rft.au=Maurer%2C+T&rft.au=Eiber%2C+M&rft.date=2018-03-01&rft.eissn=1748-717X&rft.volume=13&rft.issue=1&rft.spage=36&rft_id=info%3Apmid%2F29490670&rft.externalDocID=29490670