Quadrupole vs. Magnetic Sector Glow Discharge Mass Spectrometry: Comparison of Quantitative Analytical Capabilities
The glow discharge (GD) ion source has developed rapidly over the last several years as a versatile mass spectrometric ion source for complete elemental characterization of metal alloys at sub-ppm concentrations. Recently, the GD ion source has been coupled with a quadrupole mass spectrometer, which...
Saved in:
Published in | Journal of analytical atomic spectrometry Vol. 7; no. 6; pp. 943 - 949 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
06.01.1992
|
Online Access | Get full text |
Cover
Loading…
Abstract | The glow discharge (GD) ion source has developed rapidly over the last several years as a versatile mass spectrometric ion source for complete elemental characterization of metal alloys at sub-ppm concentrations. Recently, the GD ion source has been coupled with a quadrupole mass spectrometer, which allows fast mass scanning with detection limits of sub-ppm levels and is suitable for production ontrol and rapid characterization of 3N--5N pure materials. A comparison has been made between the well-estalished GD with a mass spectrometry double focusing magnetic sector mass spectrometer and the GD quadrupole mass spectrometer, including basic studies on polyatomic-ion abundaces, stability of relative sensitivity factors and a direct comparison of analytical results on several materials. Aluminum in steels is analyzed. |
---|---|
AbstractList | The glow discharge (GD) ion source has developed rapidly over the last several years as a versatile mass spectrometric ion source for complete elemental characterization of metal alloys at sub-ppm concentrations. Recently, the GD ion source has been coupled with a quadrupole mass spectrometer, which allows fast mass scanning with detection limits of sub-ppm levels and is suitable for production ontrol and rapid characterization of 3N--5N pure materials. A comparison has been made between the well-estalished GD with a mass spectrometry double focusing magnetic sector mass spectrometer and the GD quadrupole mass spectrometer, including basic studies on polyatomic-ion abundaces, stability of relative sensitivity factors and a direct comparison of analytical results on several materials. Aluminum in steels is analyzed. |
Author | Vieth, W Raith, A Hutton, R C Huneke, J C |
Author_xml | – sequence: 1 givenname: A surname: Raith fullname: Raith, A – sequence: 2 givenname: W surname: Vieth fullname: Vieth, W – sequence: 3 givenname: J surname: Huneke middlename: C fullname: Huneke, J C – sequence: 4 givenname: R surname: Hutton middlename: C fullname: Hutton, R C |
BookMark | eNqNjTFuwkAQRbcgEhC4w1R0IMdgG-iQgaRJEUGPBjOGReudZWcN4vbZggNQ_eJ9vddXHcuWOqqXpHkxXsyKoqv6ItckSWZZmvWU_LV48q1jQ3CXCfzi2VLQFeyoCuzh2_AD1lqqC_ozRSwCOxeZ54aCfy6h5Mah18IWuIaos0EHDPpOsLJonlGGBkp0eNRGB00yUB81GqHhaz_VaLvZlz9j5_nWkoRDE4NkDFriVg5pNp_m8-xr-vbxHxoWUNQ |
ContentType | Journal Article |
DBID | 8BQ 8FD JG9 |
DatabaseName | METADEX Technology Research Database Materials Research Database |
DatabaseTitle | Materials Research Database Technology Research Database METADEX |
DatabaseTitleList | Materials Research Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Chemistry Physics |
EndPage | 949 |
GroupedDBID | 0R~ 186 1TJ 29J 53G 5GY 8BQ 8FD AAMEH AANOJ AAXHV ABJNI ABPDG ACGFO ACGFS ACHDF ACIWK ACMRT ADMRA AEFDR AENEX AGKEF AGRSR AHGXI AI. ALMA_UNASSIGNED_HOLDINGS ANLMG ANUXI ASPBG AVWKF AZFZN BBWZM BLAPV C6K CS3 DU5 EEHRC F5P FEDTE HVGLF HZ~ H~N IDY JG9 L-8 M4U N9A NDZJH O9- P2P R56 R7B RAOCF RIG RNS ROL RRA RRC RRXOS SKM SLF SLH TN5 TWZ UPT VH1 YQT ~02 |
ID | FETCH-proquest_miscellaneous_258368513 |
ISSN | 0267-9477 |
IngestDate | Fri Oct 25 03:09:19 EDT 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 6 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-proquest_miscellaneous_258368513 |
Notes | SourceType-Scholarly Journals-2 ObjectType-Conference Paper-1 content type line 23 SourceType-Conference Papers & Proceedings-1 ObjectType-Feature-2 ObjectType-Article-3 |
PQID | 25836851 |
PQPubID | 23500 |
ParticipantIDs | proquest_miscellaneous_25836851 |
PublicationCentury | 1900 |
PublicationDate | 19920106 |
PublicationDateYYYYMMDD | 1992-01-06 |
PublicationDate_xml | – month: 01 year: 1992 text: 19920106 day: 06 |
PublicationDecade | 1990 |
PublicationTitle | Journal of analytical atomic spectrometry |
PublicationYear | 1992 |
SSID | ssj0004525 |
Score | 2.8223891 |
Snippet | The glow discharge (GD) ion source has developed rapidly over the last several years as a versatile mass spectrometric ion source for complete elemental... |
SourceID | proquest |
SourceType | Aggregation Database |
StartPage | 943 |
Title | Quadrupole vs. Magnetic Sector Glow Discharge Mass Spectrometry: Comparison of Quantitative Analytical Capabilities |
URI | https://search.proquest.com/docview/25836851 |
Volume | 7 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnZ1NS8NAEIYXWxC9iFbFb_cgXqTFNh9tvZXQUqStWFLtLWSTjXhJpEkU_PXO7G6alQpVLyEsIQl5ltmdycw7hFwxZoeRbaJvYlt1s-mDHWSBAXOZweISMIOJ0MV4Yg9n5v3cmhf97lV1ScYaweePdSX_oQpjwBWrZP9AdnlTGIBz4AtHIAzHXzF-zP1wkb9hguB72rgZ-y8x1iRiEB1cacyk-EB5TaGGhD2GwKhhv_kMJQqyhdB6cvQ-hJjiGYuqM8wnEnolMtTtwJIqsmiLlMPV7axfXg1-PGbcp9qjtN9JMpCznDhPr1yOPJczLOZKBrSM4Q7zTCX6T9VgqGr3WiJUYWsWrQVWuWuqvi3K_La1Waab0q6Ub1KrclcKm34XzJ48eIPZaOS5_blbIRWjiTmd02lPl4u3ZJBNPndlwRW7CHeX7KjvRXuS5R7Z4HGNbDlF170a2RQpuUG6T9KSLgW6tKBLJV2KdOmSLkW6VKd7R0u2NImozpaWbKnO9oBcD_quM6wX7-_Be-G_HT_mSZ56LauDrQSaxiGpxknMjwjthLD3iMAhsEPwsY12x2J-5N9ycCIjxk3zmFyuudnJ2itOyXYJ-oxUs0XOz2GXlrELQeILAP1Oxg |
link.rule.ids | 315,783,787 |
linkProvider | Royal Society of Chemistry |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Quadrupole+vs.+Magnetic+Sector+Glow+Discharge+Mass+Spectrometry%3A+Comparison+of+Quantitative+Analytical+Capabilities&rft.jtitle=Journal+of+analytical+atomic+spectrometry&rft.au=Raith%2C+A&rft.au=Vieth%2C+W&rft.au=Huneke%2C+J+C&rft.au=Hutton%2C+R+C&rft.date=1992-01-06&rft.issn=0267-9477&rft.volume=7&rft.issue=6&rft.spage=943&rft.epage=949&rft.externalDBID=NO_FULL_TEXT |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0267-9477&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0267-9477&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0267-9477&client=summon |