Clinical Manifestations After Exposure to a "Not Dangerous" Product in Two Patients

Triethoxyoctylsilane / 2-butoxyethanol aqueous emulsion (Pulvistop Geal registered ) is a water-repellent product used particularly in the building trade. According to European dispositions it is considered a "not dangerous" product and no indications about use with compressor-machines are...

Full description

Saved in:
Bibliographic Details
Published inClinical toxicology (Philadelphia, Pa.) Vol. 46; no. 5; p. 414
Main Authors Giampreti, A, Petrolini, V, Lonati, D, Vecchio, S, Locatelli, C, Manzo, L
Format Journal Article
LanguageEnglish
Published 01.06.2008
Online AccessGet full text

Cover

Loading…
Abstract Triethoxyoctylsilane / 2-butoxyethanol aqueous emulsion (Pulvistop Geal registered ) is a water-repellent product used particularly in the building trade. According to European dispositions it is considered a "not dangerous" product and no indications about use with compressor-machines are mentioned in technical issues. Objective: We describe two cases of chemical alveolitis after inhalation of Pulvistop Geal registered emulsion nebulized through a compressor-machine. Case series: Case 1 - A 34 year old man was admitted to the Emergency Department (ED) eight hours after exposure to a silane aqueous emulsion; the product was nebulized with a compressor-machine and inhaled for two hours. At admission the patient presented with chest pain and dyspnoea; gas analysis revealed arterial hypoxia so oxygen was immediately administered. The chest radiograph was normal and a CT scan subsequently performed revealed a bilateral alveolo-interstitial infiltrate in the medium-upper lung areas. CPAP was started and corticosteroids and antibiotics were administered. A complete clinical recovery was obtained in three days without sequelae. Case 2 - A 50 year old man presented to the ED after inhalation of a silane emulsion sprayed from a compressor-machine in the morning. After exposure he manifested chest tightness, upper airways burning sensation and expiratory whistle. At presentation the patient presented with mild upper airways irritation and neutrophilic leukocytosis. Vital parameters and gas analysis were normal. Chest radiograph showed thickening of peribronchovascular interstitium at medium-upper lung areas and CT scan confirmed a diffused chemical alveolitis with interstitial consolidation. Oxygen, bronchodilators and corticosteroids were administered and a complete clinical recovery occurred during the next day. CT scan repeated seven days later showed a complete restitutio ad integrum. Conclusion: Exposure to "not dangerous" products may be associated with negative effects on health when the product is used in an incorrect way. After these cases the producer was alerted and product documentation was altered to include the phrase "do not use with compressors" and to both the product documentation and Safety Data Sheet were added the caution phrase "do not breathe vapors/aerosol". Poison Control Centres can play a key role in toxicovigilance and in detection of newly emerging poisonings.
AbstractList Triethoxyoctylsilane / 2-butoxyethanol aqueous emulsion (Pulvistop Geal registered ) is a water-repellent product used particularly in the building trade. According to European dispositions it is considered a "not dangerous" product and no indications about use with compressor-machines are mentioned in technical issues. Objective: We describe two cases of chemical alveolitis after inhalation of Pulvistop Geal registered emulsion nebulized through a compressor-machine. Case series: Case 1 - A 34 year old man was admitted to the Emergency Department (ED) eight hours after exposure to a silane aqueous emulsion; the product was nebulized with a compressor-machine and inhaled for two hours. At admission the patient presented with chest pain and dyspnoea; gas analysis revealed arterial hypoxia so oxygen was immediately administered. The chest radiograph was normal and a CT scan subsequently performed revealed a bilateral alveolo-interstitial infiltrate in the medium-upper lung areas. CPAP was started and corticosteroids and antibiotics were administered. A complete clinical recovery was obtained in three days without sequelae. Case 2 - A 50 year old man presented to the ED after inhalation of a silane emulsion sprayed from a compressor-machine in the morning. After exposure he manifested chest tightness, upper airways burning sensation and expiratory whistle. At presentation the patient presented with mild upper airways irritation and neutrophilic leukocytosis. Vital parameters and gas analysis were normal. Chest radiograph showed thickening of peribronchovascular interstitium at medium-upper lung areas and CT scan confirmed a diffused chemical alveolitis with interstitial consolidation. Oxygen, bronchodilators and corticosteroids were administered and a complete clinical recovery occurred during the next day. CT scan repeated seven days later showed a complete restitutio ad integrum. Conclusion: Exposure to "not dangerous" products may be associated with negative effects on health when the product is used in an incorrect way. After these cases the producer was alerted and product documentation was altered to include the phrase "do not use with compressors" and to both the product documentation and Safety Data Sheet were added the caution phrase "do not breathe vapors/aerosol". Poison Control Centres can play a key role in toxicovigilance and in detection of newly emerging poisonings.
Author Petrolini, V
Vecchio, S
Giampreti, A
Lonati, D
Locatelli, C
Manzo, L
Author_xml – sequence: 1
  givenname: A
  surname: Giampreti
  fullname: Giampreti, A
– sequence: 2
  givenname: V
  surname: Petrolini
  fullname: Petrolini, V
– sequence: 3
  givenname: D
  surname: Lonati
  fullname: Lonati, D
– sequence: 4
  givenname: S
  surname: Vecchio
  fullname: Vecchio, S
– sequence: 5
  givenname: C
  surname: Locatelli
  fullname: Locatelli, C
– sequence: 6
  givenname: L
  surname: Manzo
  fullname: Manzo, L
BookMark eNqNjbsKwkAQRbdQMD7-YbCwE5KsEVNKVGwUwfRhiRNZWWfizgb9fFP4AVa3OefcsRoQEw5UlGTZeqnXWTxSY5FHHOvNKk8idS2cJVsbBydDtkEJJlgmgW0T0MP-07J0HiEwGJifOcDO0B09dzKHi-dbVwewBOWb4dKrSEGmatgYJzj77UQtDvuyOC5bz6-uv6ieVmp0zhD2nSqNk1WuU63_Br-MHUO0
ContentType Journal Article
DBID 7U7
C1K
DatabaseName Toxicology Abstracts
Environmental Sciences and Pollution Management
DatabaseTitle Toxicology Abstracts
Environmental Sciences and Pollution Management
DatabaseTitleList Toxicology Abstracts
DeliveryMethod fulltext_linktorsrc
Discipline Public Health
EndPage 414
GroupedDBID ---
00X
03L
0BK
0R~
29B
36B
3O-
4.4
53G
5RE
5VS
7U7
AALUX
AAMIU
AAPUL
AAQRR
ABBKH
ABDBF
ABEIZ
ABJNI
ABLIJ
ABLKL
ABUPF
ABXYU
ACENM
ACGFS
ACIEZ
ADCVX
ADRBQ
AECIN
AENEX
AEOZL
AFKVX
AGDLA
AGFJD
AGRBW
AGYJP
AIJEM
AIRBT
AJWEG
AKBVH
ALMA_UNASSIGNED_HOLDINGS
ALQZU
ALYBC
AWYRJ
BABNJ
BLEHA
BOHLJ
C1K
CAG
CCCUG
COF
DKSSO
DU5
EAP
EAS
EBC
EBD
EDH
EHN
EMB
EMK
EMOBN
EPL
EPT
ESX
F5P
H13
HZ~
KRBQP
KSSTO
KWAYT
KYCEM
M44
M4Z
O9-
Q~Q
RNANH
RVRKI
SV3
TBQAZ
TDBHL
TERGH
TFDNU
TFL
TFW
TUROJ
TUS
UHWXJ
V1S
~1N
ID FETCH-proquest_miscellaneous_201493233
ISSN 1556-3650
IngestDate Fri Oct 25 09:31:32 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 5
Language English
LinkModel OpenURL
MergedId FETCHMERGED-proquest_miscellaneous_201493233
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
content type line 23
ObjectType-Feature-2
PQID 20149323
PQPubID 23462
ParticipantIDs proquest_miscellaneous_20149323
PublicationCentury 2000
PublicationDate 20080601
PublicationDateYYYYMMDD 2008-06-01
PublicationDate_xml – month: 06
  year: 2008
  text: 20080601
  day: 01
PublicationDecade 2000
PublicationTitle Clinical toxicology (Philadelphia, Pa.)
PublicationYear 2008
SSID ssj0038491
Score 3.7159486
Snippet Triethoxyoctylsilane / 2-butoxyethanol aqueous emulsion (Pulvistop Geal registered ) is a water-repellent product used particularly in the building trade....
SourceID proquest
SourceType Aggregation Database
StartPage 414
Title Clinical Manifestations After Exposure to a "Not Dangerous" Product in Two Patients
URI https://search.proquest.com/docview/20149323
Volume 46
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnZ3bT8IwFMYbxRcTY7zGuw0xvo3IuhuPgCAxgCYOw9tSxiZ9cCM4I_Gv95ytHSyaoL4s28I2sl_Wnn495yshV7Zt2tzByl_HDzVDD7nGWWBrljMyanbVgE4LZ3R7faszMO6H5lAtMC6rS5JRxf_8sa7kP1ThHHDFKtk_kM1vCidgH_jCFgjD9leMm6qssccxReUtkXlt9XTh79Z8GqP-h-ElB8R6P06Q8kswg-E-HGOVANq9oubhfsRo1y-UtVPuXqAekcRz4WeGTRCUog6DBpPTSZZs-8grS5rCneCvmMgoCmIpLt6FSwSJQm5tF-V7Ucg9fgbgExEvhFmlSjiL7CnVkJqWxqzMVFa1tFJsFMtz2WmzaWSFpLIHzo-WzbH7D1570O16bmvorpN1VjVLZKPeuG20VcfLHKOW2ePKR3_rXtOYwd0h2zLYp_WM3C5ZC6I9spUppTQrANsnT-oV0yJFmlKkiiJNYsppGRjSnGGZSoJURBQIUkXwgFy3W26zo6l_5sHnjHM0PArgOk_HISvTGTskpSiOgiNC_dAwdJvDUP0Gvh8zqIVjppsQOY-5OfLD6jG5XHGzk5W_OCWbC4pnpJTM3oNziLaS0YV8y18sHzWh
link.rule.ids 315,783,787
linkProvider EBSCOhost
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Clinical+Manifestations+After+Exposure+to+a+%22Not+Dangerous%22+Product+in+Two+Patients&rft.jtitle=Clinical+toxicology+%28Philadelphia%2C+Pa.%29&rft.au=Giampreti%2C+A&rft.au=Petrolini%2C+V&rft.au=Lonati%2C+D&rft.au=Vecchio%2C+S&rft.date=2008-06-01&rft.issn=1556-3650&rft.volume=46&rft.issue=5&rft.spage=414&rft.epage=414&rft.externalDBID=NO_FULL_TEXT
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1556-3650&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1556-3650&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1556-3650&client=summon