Methylated Poly(ethylene)imine Modified Capacitive Micromachined Ultrasonic Transducer for Measurements of CO2 and SO2 in Their Mixtures

A gravimetric gas detection device based on surface functionalized Capacitive Micromachined Ultrasound Transducers (CMUTs) was designed, fabricated and tested for detection of carbon dioxide (CO2) and sulfur dioxide (SO2) mixtures in nitrogen. The created measurement setup of continuous data collect...

Full description

Saved in:
Bibliographic Details
Published inSensors (Basel, Switzerland) Vol. 19; no. 14
Main Authors Barauskas, Dovydas, Pelenis, Donatas, Vanagas, Gailius, Viržonis, Darius, Baltrušaitis, Jonas
Format Journal Article
LanguageEnglish
Published United States MDPI AG 01.07.2019
Subjects
Online AccessGet full text

Cover

Loading…
Abstract A gravimetric gas detection device based on surface functionalized Capacitive Micromachined Ultrasound Transducers (CMUTs) was designed, fabricated and tested for detection of carbon dioxide (CO2) and sulfur dioxide (SO2) mixtures in nitrogen. The created measurement setup of continuous data collection, integrated with an in-situ Fourier Transform Infrared (FT-IR) spectroscopy, allows for better understanding of the mechanisms and molecular interactions with the sensing layer (methylated poly(ethylene)imine) and its need of surface functionalization for multiple gas detection. During experimentation with CO2 gases, weak molecular interactions were observed in spectroscopy data. Linear sensor response to frequency shift was observed with CO2 concentrations ranging from 0.16 vol % to 1 vol %. Moreover, the Raman and FT-IR spectroscopy data showed much stronger SO2 and the polymer interactions, molecules were bound by stronger forces and irreversibly changed the polymer film properties. However, the sensor change in resonance frequency in the tested region of 1 vol % to 5 vol % SO2 showed a linear response. This effect changed not only the device resonance frequency but also affected the magnitude of electroacoustic impedance which was used for differentiating the gas mixture of CO2, SO2, in dry N2.
AbstractList A gravimetric gas detection device based on surface functionalized Capacitive Micromachined Ultrasound Transducers (CMUTs) was designed, fabricated and tested for detection of carbon dioxide (CO2) and sulfur dioxide (SO2) mixtures in nitrogen. The created measurement setup of continuous data collection, integrated with an in-situ Fourier Transform Infrared (FT-IR) spectroscopy, allows for better understanding of the mechanisms and molecular interactions with the sensing layer (methylated poly(ethylene)imine) and its need of surface functionalization for multiple gas detection. During experimentation with CO2 gases, weak molecular interactions were observed in spectroscopy data. Linear sensor response to frequency shift was observed with CO2 concentrations ranging from 0.16 vol % to 1 vol %. Moreover, the Raman and FT-IR spectroscopy data showed much stronger SO2 and the polymer interactions, molecules were bound by stronger forces and irreversibly changed the polymer film properties. However, the sensor change in resonance frequency in the tested region of 1 vol % to 5 vol % SO2 showed a linear response. This effect changed not only the device resonance frequency but also affected the magnitude of electroacoustic impedance which was used for differentiating the gas mixture of CO2, SO2, in dry N2.
Author Barauskas, Dovydas
Vanagas, Gailius
Pelenis, Donatas
Baltrušaitis, Jonas
Viržonis, Darius
Author_xml – sequence: 1
  orcidid: 0000000315152755
  fullname: Barauskas, Dovydas
  organization: ORCID:0000000315152755
– sequence: 2
  fullname: Pelenis, Donatas
– sequence: 3
  fullname: Vanagas, Gailius
– sequence: 4
  orcidid: 0000000294163526
  fullname: Viržonis, Darius
  organization: ORCID:0000000294163526
– sequence: 5
  fullname: Baltrušaitis, Jonas
BackLink https://www.osti.gov/biblio/1611882$$D View this record in Osti.gov
BookMark eNqNjctKw0AUhgepYKsufIODK11U5xJKug6Km1DBuC7D5IQcSc7InKnYN_CxHcSFS1f_7YN_pRYcGZW6MvrOua2-F7M1lbNuc6KWprLVurZWL_74M7USedPaOufqpfpqMY_HyWfs4TlOx5ufiIy3NBMjtLGngcrY-HcfKNNH6SikOPswFqCH1yknL5EpQJc8S38ImGCICVr0ckg4I2eBOECzs-C5h5eixNCNSAWiz1wguVCng58EL3_1XF0_PnTN0zpKpr2UawxjiMwY8t5sjKlr6_4FfQN6ylnq
ContentType Journal Article
CorporateAuthor Georgia Inst. of Technology, Atlanta, GA (United States)
CorporateAuthor_xml – name: Georgia Inst. of Technology, Atlanta, GA (United States)
DBID OTOTI
DOI 10.3390/s19143236
DatabaseName OSTI.GOV
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
Chemistry
EISSN 1424-8220
ExternalDocumentID 1611882
GroupedDBID ---
123
2WC
3V.
53G
5VS
7X7
88E
8FE
8FG
8FI
8FJ
AADQD
ABDBF
ABJCF
ABPTK
ABUWG
ADBBV
AENEX
AFKRA
ALMA_UNASSIGNED_HOLDINGS
ARAPS
BENPR
BGLVJ
BPHCQ
BVXVI
CS3
D1I
DKF
DU5
E3Z
EBD
ESX
F5P
FYUFA
GROUPED_DOAJ
GX1
HCIFZ
HH5
HYE
KB.
KQ8
L6V
M1P
M48
M7S
M~E
OK1
OTOTI
P2P
P62
PDBOC
PIMPY
PQEST
PQQKQ
PQUKI
PROAC
PSQYO
PTHSS
RNS
RPM
TUS
UKHRP
XSB
~8M
ID FETCH-osti_scitechconnect_16118823
IEDL.DBID M48
ISSN 1424-8220
IngestDate Fri May 19 01:09:08 EDT 2023
IsPeerReviewed true
IsScholarly true
Issue 14
Language English
LinkModel DirectLink
MergedId FETCHMERGED-osti_scitechconnect_16118823
Notes USDOE Office of Science (SC)
SC0012577
ORCID 0000000315152755
0000000294163526
ParticipantIDs osti_scitechconnect_1611882
PublicationCentury 2000
PublicationDate 2019-07-01
PublicationDateYYYYMMDD 2019-07-01
PublicationDate_xml – month: 07
  year: 2019
  text: 2019-07-01
  day: 01
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Sensors (Basel, Switzerland)
PublicationYear 2019
Publisher MDPI AG
Publisher_xml – name: MDPI AG
SSID ssj0023338
Score 4.610369
Snippet A gravimetric gas detection device based on surface functionalized Capacitive Micromachined Ultrasound Transducers (CMUTs) was designed, fabricated and tested...
SourceID osti
SourceType Open Access Repository
SubjectTerms Chemistry
Engineering
Instruments & Instrumentation
Title Methylated Poly(ethylene)imine Modified Capacitive Micromachined Ultrasonic Transducer for Measurements of CO2 and SO2 in Their Mixtures
URI https://www.osti.gov/biblio/1611882
Volume 19
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV1NS8NAEB1qe1APolVRq2ERD3qI5quxOYhoaClCatEWeiubZBcKIcEkQvsP_NnObFqtID2FsOxCdtl9bzJv3wBciZDEfrHUQ_IZcrzQ1D0pDb3jhpHBuXEvuFJbDNz-2HmZtCc1WNXYXE5g8W9oR_WkxnlyO_9YPOKGf6CIE0P2u4I8ymzLdregYTkYoJOCz_lJJli2rQpa050uHfHQqAyG_nbFEznDPbWGLb192FuSQvZUreIB1ETahG1_VYutCbtrtoGH8BUInN4EWWLMhlmyuFaveGjdUIkuwYIsnkmklsxHJIyUOIgFSninlJPYME7KnBfkissUWMW4wDlD_sqC33-GBcsk818txtOYveNzlrIR5RVwsDklHoojuOx1R35fp4-aIpiSI2xE0pmonCLJM5FY28dQT7NUnABr85hLS5qhpHuy3OQYVnVcbgtPGCbvRKfQ2jDQ2cbWFuwgyfAqies51Mv8U1wgkJehBo3n7mD4pqlAWFOL9g24AKaf
link.rule.ids 230,315,783,787,867,888,24330,27936,27937
linkProvider Scholars Portal
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Methylated+Poly%28ethylene%29imine+Modified+Capacitive+Micromachined+Ultrasonic+Transducer+for+Measurements+of+CO2+and+SO2+in+Their+Mixtures&rft.jtitle=Sensors+%28Basel%2C+Switzerland%29&rft.au=Barauskas%2C+Dovydas&rft.au=Pelenis%2C+Donatas&rft.au=Vanagas%2C+Gailius&rft.au=Vir%C5%BEonis%2C+Darius&rft.date=2019-07-01&rft.pub=MDPI+AG&rft.issn=1424-8220&rft.eissn=1424-8220&rft.volume=19&rft.issue=14&rft_id=info:doi/10.3390%2Fs19143236&rft.externalDocID=1611882
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1424-8220&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1424-8220&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1424-8220&client=summon