Augmentation with Transcortical Wiring of an Onlay-type Prosthesis for a Defi cient Patella during Revision Total Knee Arthroplasty

The management of patellae with a severe bony deficiency during revision total knee arthroplasty is a challenging problem. However, using a technique of augmentation with transcortical wiring of an onlay-type prosthesis allowed the authors to revise adefi cient patellae successfully. After making th...

Full description

Saved in:
Bibliographic Details
Published inClinics in orthopedic surgery pp. 163 - 166
Main Authors 서재곤, 문영완, 임승재, Ji-Soon Lim, Sang-Min Kim
Format Journal Article
LanguageEnglish
Published 대한정형외과학회 01.06.2012
Subjects
Online AccessGet full text
ISSN2005-291X
2005-4408

Cover

Abstract The management of patellae with a severe bony deficiency during revision total knee arthroplasty is a challenging problem. However, using a technique of augmentation with transcortical wiring of an onlay-type prosthesis allowed the authors to revise adefi cient patellae successfully. After making the decision to revise the existing patellar component, the procedure was found to betechnically straightforward. Furthermore, the procedure does not require sophisticated instruments, only an onlay-type prosthesis,cement and wires. This technique entails fi xing wires to the three pegs of the patellar component, passing the wires through drillholes in the anterior cortex and, after compression of a cemented prosthesis, augmenting the fi xation by twisting the wires anteriorly. We believe that stable fi xation and painless articulation will be obtained with the described technique for defi cient patellae. KCI Citation Count: 0
AbstractList The management of patellae with a severe bony deficiency during revision total knee arthroplasty is a challenging problem. However, using a technique of augmentation with transcortical wiring of an onlay-type prosthesis allowed the authors to revise adefi cient patellae successfully. After making the decision to revise the existing patellar component, the procedure was found to betechnically straightforward. Furthermore, the procedure does not require sophisticated instruments, only an onlay-type prosthesis,cement and wires. This technique entails fi xing wires to the three pegs of the patellar component, passing the wires through drillholes in the anterior cortex and, after compression of a cemented prosthesis, augmenting the fi xation by twisting the wires anteriorly. We believe that stable fi xation and painless articulation will be obtained with the described technique for defi cient patellae. KCI Citation Count: 0
Author 임승재
Ji-Soon Lim
서재곤
문영완
Sang-Min Kim
Author_xml – sequence: 1
  fullname: 서재곤
  organization: (성균관대학교)
– sequence: 2
  fullname: 문영완
  organization: (성균관대학교)
– sequence: 3
  fullname: 임승재
  organization: (성균관대학교)
– sequence: 4
  fullname: Ji-Soon Lim
  organization: (Sungkyunkwan University)
– sequence: 5
  fullname: Sang-Min Kim
  organization: (Sungkyunkwan University)
BackLink https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001901121$$DAccess content in National Research Foundation of Korea (NRF)
BookMark eNqVjM1Kw0AURgdpwdb6DnfpJjBNm6jL4A-Ki5YS0N1wiZPk2vHeMnOrZO2LW0tfwNX5Ft85UzNiYX9mJrm1RbZc2pvRaee387dzM03pw9qyKK_txPxU--7Ts6KSMHyT9lBH5NRIVGowwCtF4g6kBWRYccAh02HnYR0lae8TJWglAsK9bwkaOrRgjepDQHjfH92N_6L0l69FD8UX9h6qqH2UXcCkw8yMWwzJX554Ya4eH-q7p4xj67YNOUE6shO3ja7a1M9uUebzolz84_oLAyJZCQ
ContentType Journal Article
DBID ACYCR
DatabaseName Korean Citation Index
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
EISSN 2005-4408
EndPage 166
ExternalDocumentID oai_kci_go_kr_ARTI_362156
GroupedDBID ---
5-W
53G
8JR
8XY
9ZL
ACYCR
ADBBV
ADRAZ
ALMA_UNASSIGNED_HOLDINGS
AOIJS
BAWUL
BCNDV
C1A
DIK
E3Z
EBD
EF.
EMOBN
F5P
FRP
GROUPED_DOAJ
HYE
KQ8
M48
M~E
O5R
O5S
OK1
RPM
SV3
TR2
W2D
ID FETCH-nrf_kci_oai_kci_go_kr_ARTI_3621563
ISSN 2005-291X
IngestDate Tue Nov 21 21:40:59 EST 2023
IsPeerReviewed true
IsScholarly true
Language English
LinkModel OpenURL
MergedId FETCHMERGED-nrf_kci_oai_kci_go_kr_ARTI_3621563
Notes G704-SER000002656.2012.4.2.003
ParticipantIDs nrf_kci_oai_kci_go_kr_ARTI_362156
PublicationCentury 2000
PublicationDate 2012-06
PublicationDateYYYYMMDD 2012-06-01
PublicationDate_xml – month: 06
  year: 2012
  text: 2012-06
PublicationDecade 2010
PublicationTitle Clinics in orthopedic surgery
PublicationYear 2012
Publisher 대한정형외과학회
Publisher_xml – name: 대한정형외과학회
SSID ssj0065670
Score 3.7046316
Snippet The management of patellae with a severe bony deficiency during revision total knee arthroplasty is a challenging problem. However, using a technique of...
SourceID nrf
SourceType Open Website
StartPage 163
SubjectTerms 정형외과학
Title Augmentation with Transcortical Wiring of an Onlay-type Prosthesis for a Defi cient Patella during Revision Total Knee Arthroplasty
URI https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001901121
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX Clinics in Orthopedic Surgery, 2012, 4(2), , pp.163-166
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3db9MwELe6PfGCQID4GjokIiFVQcvsNs5jGorGN4Ii9lYlqTOibQkq7cP2yn_KX8LvnDRx0RCDl-hiOZeL7hf7zr47C_FE5mahi0XgZ7AdfJWa1NejDM5Kvm8w4xewcDnB-e278eFn9epodDQY_HSiltar7Fl-cWleyf9oFW3QK2fJ_oNmO6ZoAA394goN43olHcfr47M2d6jJxm5qlcOhbFaov5TLNqgZf_H76jQ99-2S6wdO9fhquBaJDaLEqFOUQ5sayTX7OSBqk7_4sc0-H85qTpt8XRnDC_p8uALs7tXWpnBTY9QG2PJuUP2NN4GG353Ea2jWmyaeVl6UMBFNvRhE7E2kF6u-y4SbJ9p20TB2LRF5Wrlc8DAYMTs8H3Xsupig0v9UQ_A35Zm7tMExImN3aYPfphOO-Jg-96JRK1m8zzS3aEvY97NEVtZJsukcWSIGh35ItXVXDyJ7SA9mv76Nz912hvGgHXRNe3dJse7fJtGtct0neTk_rucnyzmckpdz2AjwknfEjgw6p7-xFWBM2-MMO7lg4VTLwrFwZjfE9dY1objB2U0xMNUt8cPFGDHGaAtj1GCM6oLSinqMUY8xAsYoJcYYWYxRizFqMEYbjJHFGDHGyMXYbfH0xXSWHPoQ2n71H79e3hG7VV2Zu4IKGao8CMMgVVLpsYbDnWVhvlChlAeZkffE47-yu3-FPg_EtR5UD8Xuark2e7AgV9kjq4RfwiZwdQ
linkProvider Directory of Open Access Journals
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Augmentation+with+Transcortical+Wiring+of+an+Onlay-type+Prosthesis+for+a+Defi+cient+Patella+during+Revision+Total+Knee+Arthroplasty&rft.jtitle=Clinics+in+orthopedic+surgery&rft.au=%EC%84%9C%EC%9E%AC%EA%B3%A4&rft.au=%EB%AC%B8%EC%98%81%EC%99%84&rft.au=%EC%9E%84%EC%8A%B9%EC%9E%AC&rft.au=Ji-Soon+Lim&rft.date=2012-06-01&rft.pub=%EB%8C%80%ED%95%9C%EC%A0%95%ED%98%95%EC%99%B8%EA%B3%BC%ED%95%99%ED%9A%8C&rft.issn=2005-291X&rft.eissn=2005-4408&rft.spage=163&rft.epage=166&rft.externalDBID=n%2Fa&rft.externalDocID=oai_kci_go_kr_ARTI_362156
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2005-291X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2005-291X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2005-291X&client=summon