Utility of 3D Echocardiography for Device Sizing During Transcatheter ASD Closure: A Comparative Study

BACKGROUND: Two-dimensional (2D) transesophageal echocardiography (TEE) is commonly used for assessing patients undergoing transcatheter atrial septal defect (ASD) device closure. 3D TEE, albeit providing high resolution en-face images of ASD, is used in only a fraction of cases. We aimed to perform...

Full description

Saved in:
Bibliographic Details
Published inJournal of cardiovascular imaging Vol. 31; no. 4; pp. 180 - 187
Main Authors Avinash Mani, Sivadasanpillai Harikrishnan, Bijulal Sasidharan, Sanjay Ganapathi, Ajit Kumar Valaparambil
Format Journal Article
LanguageKorean
Published 2023
Subjects
Online AccessGet full text

Cover

Loading…
Abstract BACKGROUND: Two-dimensional (2D) transesophageal echocardiography (TEE) is commonly used for assessing patients undergoing transcatheter atrial septal defect (ASD) device closure. 3D TEE, albeit providing high resolution en-face images of ASD, is used in only a fraction of cases. We aimed to perform a comparative analysis between 3D and 2D TEE assessment for ASD device planning. METHODS: This was a prospective, observational study conducted over a period of one year. Patients deemed suitable for device closure underwent 2D and 3D TEE at baseline. Defect characteristics, assessed separately in both modalities, were compared. Using regression analysis, we aimed to derive an equation for predicting device size using 3D TEE parameters. RESULTS: Thirty patients were included in the study, majority being females (83%). The mean age of the study population was 40.5 ± 12.05 years. Chest pain, dyspnea and palpitations were the common presenting complaints. All patients had suitable rims on 2D TEE. A good agreement was noted between 2D and 3D TEE for measured ASD diameters. 3D TEE showed that majority of defects were circular in shape (60%). The final device size used had high degree of correlation with 3D defect area and circumference. An equation was devised to predict device size using 3D defect area and circumference. The mean device size obtained from the equation was similar to the actual device size used in the study population (p = 0.31). CONCLUSIONS: Device sizing based on 3D TEE parameters alone is equally effective for transcatheter ASD closure as compared to 2D TEE.
AbstractList BACKGROUND: Two-dimensional (2D) transesophageal echocardiography (TEE) is commonly used for assessing patients undergoing transcatheter atrial septal defect (ASD) device closure. 3D TEE, albeit providing high resolution en-face images of ASD, is used in only a fraction of cases. We aimed to perform a comparative analysis between 3D and 2D TEE assessment for ASD device planning. METHODS: This was a prospective, observational study conducted over a period of one year. Patients deemed suitable for device closure underwent 2D and 3D TEE at baseline. Defect characteristics, assessed separately in both modalities, were compared. Using regression analysis, we aimed to derive an equation for predicting device size using 3D TEE parameters. RESULTS: Thirty patients were included in the study, majority being females (83%). The mean age of the study population was 40.5 ± 12.05 years. Chest pain, dyspnea and palpitations were the common presenting complaints. All patients had suitable rims on 2D TEE. A good agreement was noted between 2D and 3D TEE for measured ASD diameters. 3D TEE showed that majority of defects were circular in shape (60%). The final device size used had high degree of correlation with 3D defect area and circumference. An equation was devised to predict device size using 3D defect area and circumference. The mean device size obtained from the equation was similar to the actual device size used in the study population (p = 0.31). CONCLUSIONS: Device sizing based on 3D TEE parameters alone is equally effective for transcatheter ASD closure as compared to 2D TEE.
Author Sivadasanpillai Harikrishnan
Bijulal Sasidharan
Sanjay Ganapathi
Avinash Mani
Ajit Kumar Valaparambil
Author_xml – sequence: 1
  fullname: Avinash Mani
– sequence: 2
  fullname: Sivadasanpillai Harikrishnan
– sequence: 3
  fullname: Bijulal Sasidharan
– sequence: 4
  fullname: Sanjay Ganapathi
– sequence: 5
  fullname: Ajit Kumar Valaparambil
BookMark eNqNi70KwjAYAIMo-Nd3-BZHIU2MVbfSKqKDgzpLbFP7YU0kSYX69CqIs9PdcNcnbW20apEeE7PpOGLzafvnIe2SwDk8UxGGlM151CPF0WOFvgFTAE9hmZUmkzZHc7HyXjZQGAupemCmYI9P1BdIa_vBwUrtMulL5ZWFeJ9CUhlXW7WAGBJzu0srPT7em6_zZkg6haycCr4ckNFqeUjW4ys6jyedu-q0ibc7RhlnVIgZ42LCKP-3ewFqr0f9
ContentType Journal Article
DBID JDI
DEWEY 616
DatabaseName KoreaScience
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
DocumentTitleAlternate Utility of 3D Echocardiography for Device Sizing During Transcatheter ASD Closure: A Comparative Study
EISSN 2586-7296
EndPage 187
ExternalDocumentID JAKO202320558235420
GroupedDBID ABDBF
ACYCR
ADBBV
ADUKV
ALMA_UNASSIGNED_HOLDINGS
AOIJS
BMC
C6C
EBLON
HYE
JDI
OK1
ROL
RPM
RSV
SOJ
ID FETCH-kisti_ndsl_JAKO2023205582354203
ISSN 2586-7210
IngestDate Wed Jul 31 05:33:21 EDT 2024
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 4
Keywords Atrial septal defects
Transesophageal echocardiography
3D echocardiography
Language Korean
LinkModel OpenURL
MergedId FETCHMERGED-kisti_ndsl_JAKO2023205582354203
Notes KISTI1.1003/JNL.JAKO202320558235420
OpenAccessLink http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO202320558235420&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
ParticipantIDs kisti_ndsl_JAKO202320558235420
PublicationCentury 2000
PublicationDate 2023
PublicationDateYYYYMMDD 2023-01-01
PublicationDate_xml – year: 2023
  text: 2023
PublicationDecade 2020
PublicationTitle Journal of cardiovascular imaging
PublicationTitleAlternate Journal of cardiovascular imaging
PublicationYear 2023
SSID ssib051102937
ssj0002022021
Score 4.4829116
Snippet BACKGROUND: Two-dimensional (2D) transesophageal echocardiography (TEE) is commonly used for assessing patients undergoing transcatheter atrial septal defect...
SourceID kisti
SourceType Open Access Repository
StartPage 180
Title Utility of 3D Echocardiography for Device Sizing During Transcatheter ASD Closure: A Comparative Study
URI http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO202320558235420&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
Volume 31
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3LS8MwGA_Dg3gRn_gmBz2VSm3SrfM216ko00MVvEmWppg5O3Fz4A7-7X5f0tU6xReUUtIS0nw_vle-ByG7rJqEKqxxN1GcuZxx6daZlK4AjtkRQnEp0FBsX1RPr_nZTXBTqYxKUUvPw86-HH-ZV_IfqsIY0BWzZP9A2WJSGIBnoC_cgcJw_xWNr4e6l4dUsMhpASeTJrzUVqE2EYSRQlbgxHqMPoHIJiUaAWUKtmKJxEYcOc1eH12Fkzz194rgcVF-9rMGK6diWR9Mx6MCQiOdicEdBtjowo-jRyIRA5E9YrMjjSlE-h573GfvID3SXZiu58QCNhTLSRdvYpF1xYtzIjJhGimXPRY2ndiyND8Iqy7YnPYkRpXHbF_bCU_OJYMuOxwMgz0IvZKsPsiF9Ycy2lPirQg6PGucX-JyfC8IQp8F3EdXD_cYssf2a2vChkAF9fyJ1tY1Z7U-XGi6F-sHUwb1e13SRa4WyHxOAtqwiFgklfv-Eplt52ESyyTNgUH7KWURnQYGBWBQCwxqgUEtMOgHYFAABs2BcUgbtAQLamCxQvaOW1fNU9cs8jZLBr3bL36frZKZrJ-pNUJrkqu0ltQUmDHcU36dSy8NRCjrHenX02Cd7Hw_18ZPH2ySORyx7qstMjN8elbboNANOztm-98AW7xUJw
link.rule.ids 230,315,783,787,888,4033
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Utility+of+3D+Echocardiography+for+Device+Sizing+During+Transcatheter+ASD+Closure%3A+A+Comparative+Study&rft.jtitle=Journal+of+cardiovascular+imaging&rft.au=Avinash+Mani&rft.au=Sivadasanpillai+Harikrishnan&rft.au=Bijulal+Sasidharan&rft.au=Sanjay+Ganapathi&rft.date=2023&rft.issn=2586-7210&rft.eissn=2586-7296&rft.volume=31&rft.issue=4&rft.spage=180&rft.epage=187&rft.externalDBID=n%2Fa&rft.externalDocID=JAKO202320558235420
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2586-7210&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2586-7210&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2586-7210&client=summon