Role of Balloon Guide Catheter in Modern Endovascular Thrombectomy
Proximal flow control achieved with a balloon guide catheter (BGC) during endovascular treatment of acute ischemic stroke is reviewed in this article. In clinical practice, BGCs offer a multi-faceted approach for clot retrieval by creating proximal flow arrest, reducing embolic burden, and shortenin...
Saved in:
Published in | Journal of Korean Neurosurgical Society Vol. 63; no. 1; pp. 14 - 25 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | Korean |
Published |
2020
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Proximal flow control achieved with a balloon guide catheter (BGC) during endovascular treatment of acute ischemic stroke is reviewed in this article. In clinical practice, BGCs offer a multi-faceted approach for clot retrieval by creating proximal flow arrest, reducing embolic burden, and shortening procedure time. Evaluation of frontline thrombectomy procedures with BGCs revealed advantages of combined use over the conventional guide catheter (CGC), notably in the significant reduction of distal emboli to both the affected and previously unaffected territories. Recently, new measures of early and complete reperfusion at first thrombectomy pass have been identified as independent predictors of improved outcomes, which were consistently demonstrated with use of BGC as a safe and effective option to minimize number of passes during intervention. Prior randomized controlled trials reported the positive correlation between BGC-treated patients and a lower risk of mortality as well as shortened procedure time. While BGC use is more common in stent retriever-mediated mechanical thrombectomy, preliminary data has shown the potential benefit of device application during contact aspiration thrombectomy to achieve successful recanalization. However, the question of which major endovascular strategy reigns superior as a frontline remains to be answered. Along with clinical case assessments, BGC performance during in-vitro simulation was analyzed to further understand mechanisms for optimization of thrombectomy technique. |
---|---|
AbstractList | Proximal flow control achieved with a balloon guide catheter (BGC) during endovascular treatment of acute ischemic stroke is reviewed in this article. In clinical practice, BGCs offer a multi-faceted approach for clot retrieval by creating proximal flow arrest, reducing embolic burden, and shortening procedure time. Evaluation of frontline thrombectomy procedures with BGCs revealed advantages of combined use over the conventional guide catheter (CGC), notably in the significant reduction of distal emboli to both the affected and previously unaffected territories. Recently, new measures of early and complete reperfusion at first thrombectomy pass have been identified as independent predictors of improved outcomes, which were consistently demonstrated with use of BGC as a safe and effective option to minimize number of passes during intervention. Prior randomized controlled trials reported the positive correlation between BGC-treated patients and a lower risk of mortality as well as shortened procedure time. While BGC use is more common in stent retriever-mediated mechanical thrombectomy, preliminary data has shown the potential benefit of device application during contact aspiration thrombectomy to achieve successful recanalization. However, the question of which major endovascular strategy reigns superior as a frontline remains to be answered. Along with clinical case assessments, BGC performance during in-vitro simulation was analyzed to further understand mechanisms for optimization of thrombectomy technique. |
Author | Chueh, Ju-Yu Kang, Dong-Hun Kim, Byung Moon Gounis, Matthew J |
Author_xml | – sequence: 1 fullname: Chueh, Ju-Yu – sequence: 2 fullname: Kang, Dong-Hun – sequence: 3 fullname: Kim, Byung Moon – sequence: 4 fullname: Gounis, Matthew J |
BookMark | eNqNysEKgjAYAOARBVn5Drt0FLaZbh5TrCgiCO8y3cTR3A9Og96-Sw_Q6bt8G7R04PQCBTTJRMQFT5coYIQkUcwpXaPQe9MQIhLCaJIGKH-C1Rg6nEtrARw-z0ZpXMip15MesXH4DkqPDpdOwVv6drZyxFU_wtDodoLhs0OrTlqvw59btD-VVXGJXsZPpnbK2_p6vD0YYYRSkcY0S_lBxP--L_jYO3A |
ContentType | Journal Article |
DBID | JDI |
DEWEY | 616.8 |
DatabaseName | KoreaScience |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
DocumentTitleAlternate | Role of Balloon Guide Catheter in Modern Endovascular Thrombectomy |
EISSN | 1598-7876 |
EndPage | 25 |
ExternalDocumentID | JAKO202011863196748 |
GroupedDBID | --- .UV 29K 2WC 5-W 53G 5GY 8JR 8XY 9ZL ABDBF AENEX ALMA_UNASSIGNED_HOLDINGS CS3 D-I DIK E3Z EBD EF. F5P FRP GROUPED_DOAJ HYE JDI KVFHK OK1 RPM W2D |
ID | FETCH-kisti_ndsl_JAKO2020118631967483 |
ISSN | 2005-3711 |
IngestDate | Fri Dec 22 11:58:24 EST 2023 |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Keywords | Endovascular thrombectomy Thrombectomy Acute stroke Balloon occlusion |
Language | Korean |
LinkModel | OpenURL |
MergedId | FETCHMERGED-kisti_ndsl_JAKO2020118631967483 |
Notes | KISTI1.1003/JNL.JAKO202011863196748 |
OpenAccessLink | http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO202011863196748&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
ParticipantIDs | kisti_ndsl_JAKO202011863196748 |
PublicationCentury | 2000 |
PublicationDate | 2020 |
PublicationDateYYYYMMDD | 2020-01-01 |
PublicationDate_xml | – year: 2020 text: 2020 |
PublicationDecade | 2020 |
PublicationTitle | Journal of Korean Neurosurgical Society |
PublicationTitleAlternate | 대한신경외과학회지 |
PublicationYear | 2020 |
SSID | ssib008502156 ssib053376768 ssib038074812 ssib050733766 ssj0063085 |
Score | 4.353237 |
Snippet | Proximal flow control achieved with a balloon guide catheter (BGC) during endovascular treatment of acute ischemic stroke is reviewed in this article. In... |
SourceID | kisti |
SourceType | Open Access Repository |
StartPage | 14 |
Title | Role of Balloon Guide Catheter in Modern Endovascular Thrombectomy |
URI | http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO202011863196748&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
Volume | 63 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1JT8JAFJ4QDsaLcY0rmYMea5DpdgVFCYgmBhM8EaadSqO0SaEHPfjbfW9maAdD3C5NOyHNlPflm7c_Qk5txrgrhG1x5yKy7GgcWHwcRVboct_mHvNVbk7_zu082t2hM6xUbo2spXzOz4P3lXUl_5EqrIFcsUr2D5ItXgoLcA_yhStIGK6_kvGDTg1sYfQc22PkcShUUR_2PoyTxaizdhKWOaeDSZZOOXrrp0sxXUM37aUZeuhl545Znil21AmeZUJALiaqsMN6ygvi1v7nqzR5tjq5EeOXwGu9AbnArsrg_02KAXVVNiRHj-tAlfZENOolVcl-pszTtCk0lWKnUl9Nd1lwrSYzE1OKOFUlqT6CVSn0cnPsL4dWkUrYbfbucTNgKLlIJ56Nld_YMwjzOD_aBbn4Dqo3he6FjfZto1eZg9MrvVK3dfBJ2mLqWHdZXc53LT4VrBlU8WNDHRlskg0tK9pUoNgilZd0m6z1dabEDmkhNmgaUY0NKrFBF9igcUIVNqiJDWpiY5ecXbcHlx1LbmCUhLPX0Yr_ge2RapImYp9Q0NoC5oC1GnqgADuNsQeGtt2oc48Ll4nggNS-f9fhTz84Iuu4orxTx6Q6z3JxAvranNekHD4BRYw-zA |
link.rule.ids | 230,315,786,790,891,4043 |
linkProvider | ISSN International Centre |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Role+of+Balloon+Guide+Catheter+in+Modern+Endovascular+Thrombectomy&rft.jtitle=Journal+of+Korean+Neurosurgical+Society&rft.au=Chueh%2C+Ju-Yu&rft.au=Kang%2C+Dong-Hun&rft.au=Kim%2C+Byung+Moon&rft.au=Gounis%2C+Matthew+J&rft.date=2020&rft.issn=2005-3711&rft.eissn=1598-7876&rft.volume=63&rft.issue=1&rft.spage=14&rft.epage=25&rft.externalDBID=n%2Fa&rft.externalDocID=JAKO202011863196748 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2005-3711&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2005-3711&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2005-3711&client=summon |