Evaluation of Matrix Effects in Quantifying Microbial Secondary Metabolites in Indoor Dust Using Ultraperformance Liquid Chromatographe-Tandem Mass Spectrometer
Background: Liquid chromatography-tandem mass spectrometry (LC-MSMS) for simultaneous analysis of multiple microbial secondary metabolites (MSMs) is potentially subject to interference by matrix components. Methods: We examined potential matrix effects (MEs) in analyses of 31 MSMs using ultraperform...
Saved in:
Published in | Safety and health at work Vol. 10; no. 2; pp. 196 - 204 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | Korean |
Published |
2019
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Background: Liquid chromatography-tandem mass spectrometry (LC-MSMS) for simultaneous analysis of multiple microbial secondary metabolites (MSMs) is potentially subject to interference by matrix components. Methods: We examined potential matrix effects (MEs) in analyses of 31 MSMs using ultraperformance LC-MSMS. Twenty-one dust aliquots from three buildings (seven aliquots/building) were spiked with seven concentrations of each of the MSMs ($6.2pg/{\mu}l-900pg/{\mu}l$) and then extracted. Another set of 21 aliquots were first extracted and then, the extract was spiked with the same concentrations. We added deepoxy-deoxynivalenol (DOM) to all aliquots as a universal internal standard. Ten microliters of the extract was injected into the ultraperformance LC-MSMS. ME was calculated by subtracting the percentage of the response of analyte in spiked extract to that in neat standard from 100. Spiked extract results were used to create a matrix-matched calibration (MMC) curve for estimating MSM concentration in dust spiked before extraction. Results: Analysis of variance was used to examine effects of compound (MSM), building and concentration on response. MEs (range: 63.4%-99.97%) significantly differed by MSM (p < 0.01) and building (p < 0.05). Mean percent recoveries adjusted with DOM and the MMC method were 246.3% (SD = 226.0) and 86.3% (SD = 70.7), respectively. Conclusion: We found that dust MEs resulted in substantial underestimation in quantifying MSMs and that DOM was not an optimal universal internal standard for the adjustment but that the MMC method resulted in more accurate and precise recovery compared with DOM. More research on adjustment methods for dust MEs in the simultaneous analyses of multiple MSMs using LC-MSMS is warranted. |
---|---|
AbstractList | Background: Liquid chromatography-tandem mass spectrometry (LC-MSMS) for simultaneous analysis of multiple microbial secondary metabolites (MSMs) is potentially subject to interference by matrix components. Methods: We examined potential matrix effects (MEs) in analyses of 31 MSMs using ultraperformance LC-MSMS. Twenty-one dust aliquots from three buildings (seven aliquots/building) were spiked with seven concentrations of each of the MSMs ($6.2pg/{\mu}l-900pg/{\mu}l$) and then extracted. Another set of 21 aliquots were first extracted and then, the extract was spiked with the same concentrations. We added deepoxy-deoxynivalenol (DOM) to all aliquots as a universal internal standard. Ten microliters of the extract was injected into the ultraperformance LC-MSMS. ME was calculated by subtracting the percentage of the response of analyte in spiked extract to that in neat standard from 100. Spiked extract results were used to create a matrix-matched calibration (MMC) curve for estimating MSM concentration in dust spiked before extraction. Results: Analysis of variance was used to examine effects of compound (MSM), building and concentration on response. MEs (range: 63.4%-99.97%) significantly differed by MSM (p < 0.01) and building (p < 0.05). Mean percent recoveries adjusted with DOM and the MMC method were 246.3% (SD = 226.0) and 86.3% (SD = 70.7), respectively. Conclusion: We found that dust MEs resulted in substantial underestimation in quantifying MSMs and that DOM was not an optimal universal internal standard for the adjustment but that the MMC method resulted in more accurate and precise recovery compared with DOM. More research on adjustment methods for dust MEs in the simultaneous analyses of multiple MSMs using LC-MSMS is warranted. |
Author | Jaderson, Mukhtar Park, Ju-Hyeong |
Author_xml | – sequence: 1 fullname: Jaderson, Mukhtar – sequence: 2 fullname: Park, Ju-Hyeong |
BookMark | eNqNT8FKw0AUXKSCVfsP7-IxkE1smz1Kjag1iLQ9l5fkbftws1t3N2L_xk81inj2NAMzw8yci5F1lk7EOEtVnsyVmo_-uJRnYhIC12mmimmWynwsPst3ND1Gdhachgqj5w8otaYmBmALLz3ayPrIdgcVN97VjAZW1Djboj9CRRFrZzjSj_3Bts55uO1DhE34Dm1M9Hggr53v0DYET_zWcwuLvXcdRrcb1D0la7QtdcOAEGB1GNoHlSL5S3Gq0QSa_OKFuLor14v75JVD5K1tg9k-3iyfhztKqmI2UzK7nhb5f31f2-hflw |
ContentType | Journal Article |
DBID | JDI |
DEWEY | 658.3 |
DatabaseName | KoreaScience |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Economics Business |
DocumentTitleAlternate | Evaluation of Matrix Effects in Quantifying Microbial Secondary Metabolites in Indoor Dust Using Ultraperformance Liquid Chromatographe-Tandem Mass Spectrometer |
EISSN | 2093-7997 |
EndPage | 204 |
ExternalDocumentID | JAKO201919866912458 |
GroupedDBID | .UV .~1 0SF 1~. 4.4 457 4G. 5-W 53G 6I. 7-5 8JR AACTN AAEDT AAEDW AAFTH AAIKJ AAKDD AALRI AAXUO ABFRF ABMAC ACGFS ADBBV ADEZE ADRAZ AEFWE AEKER AEXQZ AFTJW AGHFR AITUG ALMA_UNASSIGNED_HOLDINGS AMRAJ AOIJS BCNDV EBS EF. EJD FDB FEDTE FNPLU FRP GBLVA GROUPED_DOAJ GX1 HVGLF HYE IPNFZ JDI KQ8 KVFHK M41 M48 MO0 M~E NCXOZ OK1 P-8 P-9 PC. RIG ROL RPM SSZ UNMZH W2D |
ID | FETCH-kisti_ndsl_JAKO2019198669124583 |
IEDL.DBID | M48 |
ISSN | 2093-7911 |
IngestDate | Fri Dec 22 11:58:23 EST 2023 |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 2 |
Keywords | Secondary metabolite Matrix effect Microbial Dust sample Mass spectrometry |
Language | Korean |
LinkModel | DirectLink |
MergedId | FETCHMERGED-kisti_ndsl_JAKO2019198669124583 |
Notes | KISTI1.1003/JNL.JAKO201919866912458 |
OpenAccessLink | http://journals.scholarsportal.info/openUrl.xqy?issn=2093-7911&volume=10&issue=2&spage=196 |
ParticipantIDs | kisti_ndsl_JAKO201919866912458 |
PublicationCentury | 2000 |
PublicationDate | 2019 |
PublicationDateYYYYMMDD | 2019-01-01 |
PublicationDate_xml | – year: 2019 text: 2019 |
PublicationDecade | 2010 |
PublicationTitle | Safety and health at work |
PublicationTitleAlternate | Safety and health at work : SH@W |
PublicationYear | 2019 |
SSID | ssib029852013 ssib044760121 ssib053376892 ssj0000491123 |
Score | 4.2193613 |
Snippet | Background: Liquid chromatography-tandem mass spectrometry (LC-MSMS) for simultaneous analysis of multiple microbial secondary metabolites (MSMs) is... |
SourceID | kisti |
SourceType | Open Access Repository |
StartPage | 196 |
Title | Evaluation of Matrix Effects in Quantifying Microbial Secondary Metabolites in Indoor Dust Using Ultraperformance Liquid Chromatographe-Tandem Mass Spectrometer |
URI | http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201919866912458&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
Volume | 10 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwhV3NT8IwFG8IB_ViFDV-kh6U2wwr3dhOhigE0WkMkHAj3QfJdGyyjwQu_i3-qb7XbcDB6GWHpWm3tq_v92vf-5WQa60FKyBzPcXWdK5wZ6YqQniqogMhAo_QdAwpPG-96P0xH0y0SYWUKQRFBya_Uju8T2ocB7fLxepOWggDOo56i2qjNOVmwy_YVG6PML9weWYMo72sDfJnpqGxLWbBOcaGbDwZgCDA4cWB43sOpAGZ4Hn1ulGAs4jx_C1_1Dsg-wWQpJ185A9J5SOqkZ0yjr1GdsuU4-SIfHfXmt40mlELZfmXNBcuTqgf0rdMYNAQpjxRy5faTFD3EMmyK-IVtbwUJgumK8vij6EbRTF9yJKUypgDOg5STONaJyHQZ3-R-S5F7V3AxLkutqeMcMt6Dh-QJHT4KS_gmWM8zjG56XVH931F_uo0dJNgOug8vULnmapp6LoJAEEzWiekGkahd0qoLgygYC5zuKNyWwggVKrptU3BW7ZoM3FG6n_Xdf5fgQuyh2_yjZBLUk3jzLsCaJDadTnI-Pzq_gCWiroT |
link.rule.ids | 230,315,783,787,888,2228,4031 |
linkProvider | Scholars Portal |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+Matrix+Effects+in+Quantifying+Microbial+Secondary+Metabolites+in+Indoor+Dust+Using+Ultraperformance+Liquid+Chromatographe-Tandem+Mass+Spectrometer&rft.jtitle=Safety+and+health+at+work&rft.au=Jaderson%2C+Mukhtar&rft.au=Park%2C+Ju-Hyeong&rft.date=2019&rft.issn=2093-7911&rft.eissn=2093-7997&rft.volume=10&rft.issue=2&rft.spage=196&rft.epage=204&rft.externalDBID=n%2Fa&rft.externalDocID=JAKO201919866912458 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2093-7911&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2093-7911&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2093-7911&client=summon |