Comparison of removal torques between laser-etched and modified sandblasted acid-etched Ti implant surfaces in rabbit tibias
PURPOSE. The purpose of this study was to analyze the effects of two different implant surface treatments on initial bone connection by comparing the Removal Torque Values (RTQs) at 7 and 10 days after chemically modified, sandblasted, large-grit and acid-etched (modSLA), and Laser-etched (LE) Ti im...
Saved in:
Published in | The journal of advanced prosthodontics Vol. 10; no. 1; pp. 73 - 78 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | Korean |
Published |
2018
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | PURPOSE. The purpose of this study was to analyze the effects of two different implant surface treatments on initial bone connection by comparing the Removal Torque Values (RTQs) at 7 and 10 days after chemically modified, sandblasted, large-grit and acid-etched (modSLA), and Laser-etched (LE) Ti implant placements. MATERIALS AND METHODS. Twenty modSLA and 20 LE implants were installed on the left and right tibias of 20 adult rabbits. RTQs were measured after 7 and 10 days in 10 rabbits each. Scanning electron microscope (SEM) photographs of the two implants were observed by using Quanta FEG 650 from the FEI company (Hillsboro, OR, USA). Analyses of surface elements and components were conducted using energy dispersive spectroscopy (EDS, Horiba, Kyoto, Japan). RESULTS. The mean RTQs were $12.29{\pm}0.830$ and $12.19{\pm}0.713$ Ncm after 7 days (P=.928) and $16.47{\pm}1.324$ and $16.17{\pm}1.165$ Ncm after 10 days (P=.867) for LE and modSLA, respectively, indicating no significant inter-group differences. Pore sizes in the LE were $40{\mu}m$ and consisted of numerous small pores, whereas pore sizes in the modSLA were $5{\mu}m$. In the EDS analysis, Ti, O, and C were the only three elements found in the LE surfaces. Na, Ca, Cl, and K were also observed in modSLA, in addition to Ti, O, and C. CONCLUSION. The implants showed no significant difference in biomechanical bond strength to bone in early-stage osseointegration. LE implant can be considered an excellent surface treatment method in addition to the modSLA implant and can be applied to the early loading of the prosthesis clinically. |
---|---|
AbstractList | PURPOSE. The purpose of this study was to analyze the effects of two different implant surface treatments on initial bone connection by comparing the Removal Torque Values (RTQs) at 7 and 10 days after chemically modified, sandblasted, large-grit and acid-etched (modSLA), and Laser-etched (LE) Ti implant placements. MATERIALS AND METHODS. Twenty modSLA and 20 LE implants were installed on the left and right tibias of 20 adult rabbits. RTQs were measured after 7 and 10 days in 10 rabbits each. Scanning electron microscope (SEM) photographs of the two implants were observed by using Quanta FEG 650 from the FEI company (Hillsboro, OR, USA). Analyses of surface elements and components were conducted using energy dispersive spectroscopy (EDS, Horiba, Kyoto, Japan). RESULTS. The mean RTQs were $12.29{\pm}0.830$ and $12.19{\pm}0.713$ Ncm after 7 days (P=.928) and $16.47{\pm}1.324$ and $16.17{\pm}1.165$ Ncm after 10 days (P=.867) for LE and modSLA, respectively, indicating no significant inter-group differences. Pore sizes in the LE were $40{\mu}m$ and consisted of numerous small pores, whereas pore sizes in the modSLA were $5{\mu}m$. In the EDS analysis, Ti, O, and C were the only three elements found in the LE surfaces. Na, Ca, Cl, and K were also observed in modSLA, in addition to Ti, O, and C. CONCLUSION. The implants showed no significant difference in biomechanical bond strength to bone in early-stage osseointegration. LE implant can be considered an excellent surface treatment method in addition to the modSLA implant and can be applied to the early loading of the prosthesis clinically. |
Author | Park, Kyung-Soon Cho, Sung-Am Al Awamleh, Abdel Ghani Ibrahim |
Author_xml | – sequence: 1 fullname: Park, Kyung-Soon – sequence: 2 fullname: Al Awamleh, Abdel Ghani Ibrahim – sequence: 3 fullname: Cho, Sung-Am |
BookMark | eNqNjD1PAzEQRC0UJELIf9iG8qS9r9xRogiEoKBJH63Pe8oqPjt4HWj48RwSUFPNjN7TXJtFiIEvzLJCbIuuL5vFX8fNlVmrisW2rrtNVzVL87mN04mSaAwQR0g8xXfykGN6O7OC5fzBHMCTcio4Dwd2QMHBFJ2MMg-dl51x_gaDuF9pJyDTyVPIoOc00jC_SYBE1kqGLFZIb8zlSF55_ZMrc_v4sNs-FUfRLPvg1O-f719eKyx7vGvrHpseS6z_630B1NlRlA |
ContentType | Journal Article |
DBID | JDI |
DEWEY | 617.69 |
DatabaseName | KoreaScience (Open Access) |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine Dentistry |
DocumentTitleAlternate | Comparison of removal torques between laser-etched and modified sandblasted acid-etched Ti implant surfaces in rabbit tibias |
EISSN | 2005-7814 |
EndPage | 78 |
ExternalDocumentID | JAKO201809538048010 |
GroupedDBID | .UV 34H 5-W 8JR 8XY 9ZL AAKDD ADBBV ADRAZ AENEX ALMA_UNASSIGNED_HOLDINGS AOIJS BAWUL DIK E3Z EF. F5P GX1 HYE JDI KQ8 KVFHK M48 M~E O5R O5S OK1 RPM |
ID | FETCH-kisti_ndsl_JAKO2018095380480103 |
IEDL.DBID | M48 |
ISSN | 2005-7806 |
IngestDate | Fri Dec 22 11:58:40 EST 2023 |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Keywords | Sandblasted large-grit acid-etched Energy dispersive spectroscopy Removal torque Laser treatment Scanning electron microscope |
Language | Korean |
LinkModel | DirectLink |
MergedId | FETCHMERGED-kisti_ndsl_JAKO2018095380480103 |
Notes | KISTI1.1003/JNL.JAKO201809538048010 |
OpenAccessLink | http://journals.scholarsportal.info/openUrl.xqy?issn=2005-7806&volume=10&issue=1&spage=73 |
ParticipantIDs | kisti_ndsl_JAKO201809538048010 |
PublicationCentury | 2000 |
PublicationDate | 2018 |
PublicationDateYYYYMMDD | 2018-01-01 |
PublicationDate_xml | – year: 2018 text: 2018 |
PublicationDecade | 2010 |
PublicationTitle | The journal of advanced prosthodontics |
PublicationTitleAlternate | The journal of advanced prosthodontics |
PublicationYear | 2018 |
SSID | ssib053376724 ssib030186702 ssib042018902 ssj0000447056 |
Score | 4.1524463 |
Snippet | PURPOSE. The purpose of this study was to analyze the effects of two different implant surface treatments on initial bone connection by comparing the Removal... |
SourceID | kisti |
SourceType | Open Access Repository |
StartPage | 73 |
Title | Comparison of removal torques between laser-etched and modified sandblasted acid-etched Ti implant surfaces in rabbit tibias |
URI | http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201809538048010&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
Volume | 10 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwhV1LT8JAEN4QDurFKGp8kjkot5qmLN32ZAhKCAa9QMKNsK9kI7TYlkQTf7yzSwsejB63O-nr29n5Znd2hpDbgDNUMS08JaLYo-iheJzGbS_WHOm9VJF0SI9ewsGEDqedaY1UQezlD8x_de1sPalJtrj_eP98cBri0miyyA9blSr7rep1N_rIXB7QILDBXqMd8cdRHYVsl_iKohm0G25VGzkQC1l5bsLN6ZQy35WC3T4T2ayleOaHOeofkcOSR0J3A_wxqb2lDbL_aGN_bPm2BtkblbvmJ-Srty02CKmGTC1THF-A3rY1ClCGagHyaJV5DkYJ80TCMpVGI0WFHFscuwvbIYyshMYGzHK1QHAgX2faRneBSSCbc24KcKdR8lNy138a9wae-4xZIvPFbNh9fg1cTi-cCF1qGb99RupJmqhzAlyg-grdUQgujVFornQ7YkIoKSMUviDNv-91-Z_AFTmwVzZrHNekXmRrdYNWv-BNB-A3roGrsg |
link.rule.ids | 230,315,783,787,888,2228,4031 |
linkProvider | Scholars Portal |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Comparison+of+removal+torques+between+laser-etched+and+modified+sandblasted+acid-etched+Ti+implant+surfaces+in+rabbit+tibias&rft.jtitle=The+journal+of+advanced+prosthodontics&rft.au=Park%2C+Kyung-Soon&rft.au=Al+Awamleh%2C+Abdel+Ghani+Ibrahim&rft.au=Cho%2C+Sung-Am&rft.date=2018&rft.issn=2005-7806&rft.eissn=2005-7814&rft.volume=10&rft.issue=1&rft.spage=73&rft.epage=78&rft.externalDBID=n%2Fa&rft.externalDocID=JAKO201809538048010 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2005-7806&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2005-7806&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2005-7806&client=summon |