Quenching Effect in an Optical Fiber Type Small Size Dosimeter Irradiated with 290 MeV·u -1 Carbon Ions

Background: We are developing a small size dosimeter for dose estimation in particle therapies. The developed dosimeter is an optical fiber based dosimeter mounting an radiation induced luminescence material, such as an OSL or a scintillator, at a tip. These materials generally suffer from the quenc...

Full description

Saved in:
Bibliographic Details
Published inJournal of radiation protection and research Vol. 41; no. 3; pp. 222 - 228
Main Authors Hirata, Yuho, Watanabe, Kenichi, Uritani, Akira, Yamazaki, Atsushi, Koba, Yusuke, Matsufuji, Naruhiro
Format Journal Article
LanguageKorean
Published 2016
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Background: We are developing a small size dosimeter for dose estimation in particle therapies. The developed dosimeter is an optical fiber based dosimeter mounting an radiation induced luminescence material, such as an OSL or a scintillator, at a tip. These materials generally suffer from the quenching effect under high LET particle irradiation. Materials and Methods: We fabricated two types of the small size dosimeters. They used an OSL material Eu:BaFBr and a BGO scintillator. Carbon ions were irradiated into the fabricated dosimeters at Heavy Ion Medical Accelerator in Chiba (HIMAC). The small size dosimeters were set behind the water equivalent acrylic phantom. Bragg peak was observed by changing the phantom thickness. An ion chamber was also placed near the small size dosimeters as a reference. Results and Discussion: Eu:BaFBr and BGO dosimeters showed a Bragg peak at the same thickness as the ion chamber. Under high LET particle irradiation, the response of the luminescence-based small size dosimeters deteriorated compared with that of the ion chamber due to the quenching effect. We confirmed the luminescence efficiency of Eu:BaFBr and BGO decrease with the LET. The reduction coefficient of luminescence efficiency was different between the BGO and the Eu:BaFBr. The LET can be determined from the luminescence ratio between Eu:BaFBr and BGO, and the dosimeter response can be corrected. Conclusion: We evaluated the LET dependence of the luminescence efficiency of the BGO and Eu:BaFBr as the quenching effect. We propose and discuss the correction of the quenching effect using the signal intensity ratio of the both materials. Although the correction precision is not sufficient, feasibility of the proposed correction method is proved through basic experiments.
AbstractList Background: We are developing a small size dosimeter for dose estimation in particle therapies. The developed dosimeter is an optical fiber based dosimeter mounting an radiation induced luminescence material, such as an OSL or a scintillator, at a tip. These materials generally suffer from the quenching effect under high LET particle irradiation. Materials and Methods: We fabricated two types of the small size dosimeters. They used an OSL material Eu:BaFBr and a BGO scintillator. Carbon ions were irradiated into the fabricated dosimeters at Heavy Ion Medical Accelerator in Chiba (HIMAC). The small size dosimeters were set behind the water equivalent acrylic phantom. Bragg peak was observed by changing the phantom thickness. An ion chamber was also placed near the small size dosimeters as a reference. Results and Discussion: Eu:BaFBr and BGO dosimeters showed a Bragg peak at the same thickness as the ion chamber. Under high LET particle irradiation, the response of the luminescence-based small size dosimeters deteriorated compared with that of the ion chamber due to the quenching effect. We confirmed the luminescence efficiency of Eu:BaFBr and BGO decrease with the LET. The reduction coefficient of luminescence efficiency was different between the BGO and the Eu:BaFBr. The LET can be determined from the luminescence ratio between Eu:BaFBr and BGO, and the dosimeter response can be corrected. Conclusion: We evaluated the LET dependence of the luminescence efficiency of the BGO and Eu:BaFBr as the quenching effect. We propose and discuss the correction of the quenching effect using the signal intensity ratio of the both materials. Although the correction precision is not sufficient, feasibility of the proposed correction method is proved through basic experiments.
Author Matsufuji, Naruhiro
Yamazaki, Atsushi
Watanabe, Kenichi
Uritani, Akira
Hirata, Yuho
Koba, Yusuke
Author_xml – sequence: 1
  fullname: Hirata, Yuho
– sequence: 2
  fullname: Watanabe, Kenichi
– sequence: 3
  fullname: Uritani, Akira
– sequence: 4
  fullname: Yamazaki, Atsushi
– sequence: 5
  fullname: Koba, Yusuke
– sequence: 6
  fullname: Matsufuji, Naruhiro
BookMark eNqNisFqwkAURYeiUFv9h7fpMjCTTMZkWayilSJFcSuT5MU8Or5IZkTqj7nvlzWLfkA39xw490kMuGV8EKNYGxP1owa9pzKLVJZlj2LiPRUykSrXempGovm8IJcN8RHmdY1lAGKwDJtzoNI6WFCBHey-zwjbk3UOtnRDeGs9nTD0ZdV1tiIbsIIrhQbiXMIH7n_uF4gUzGxXtAyrlv1YDGvrPE7--CxeFvPdbBl9kQ904Mq7w_vrehNLZRI5NWkutU7S5L-_X53tR-k
ContentType Journal Article
DBID JDI
DEWEY 539.2
DatabaseName KoreaScience
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
Discipline Physics
DocumentTitleAlternate Quenching Effect in an Optical Fiber Type Small Size Dosimeter Irradiated with 290 MeV·u -1 Carbon Ions
EISSN 2466-2461
EndPage 228
ExternalDocumentID JAKO201630765904435
GroupedDBID .UV
ALMA_UNASSIGNED_HOLDINGS
JDI
M~E
ID FETCH-kisti_ndsl_JAKO2016307659044353
ISSN 2508-1888
IngestDate Fri Dec 22 12:03:26 EST 2023
IsOpenAccess true
IsPeerReviewed false
IsScholarly true
Issue 3
Keywords Dosimeter
Optically stimulated luminescence
Radiotherapy
Optical fiber probe
Language Korean
LinkModel OpenURL
MergedId FETCHMERGED-kisti_ndsl_JAKO2016307659044353
Notes KISTI1.1003/JNL.JAKO201630765904435
OpenAccessLink http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201630765904435&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
ParticipantIDs kisti_ndsl_JAKO201630765904435
PublicationCentury 2000
PublicationDate 2016
PublicationDateYYYYMMDD 2016-01-01
PublicationDate_xml – year: 2016
  text: 2016
PublicationDecade 2010
PublicationTitle Journal of radiation protection and research
PublicationTitleAlternate Journal of radiation protection and research
PublicationYear 2016
SSID ssib030194476
ssib044745519
ssj0001755531
ssib053376728
Score 3.9204974
Snippet Background: We are developing a small size dosimeter for dose estimation in particle therapies. The developed dosimeter is an optical fiber based dosimeter...
SourceID kisti
SourceType Open Access Repository
StartPage 222
Title Quenching Effect in an Optical Fiber Type Small Size Dosimeter Irradiated with 290 MeV·u -1 Carbon Ions
URI http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201630765904435&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
Volume 41
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Na9tAEF1MoJBLaJuUpmnNHOqTkLGt1So6uibBdkhCSFLsk1nJayISy8GSLj60P6v3_rLO7K5k54Mm7UWItbRInsfsm9GbWca-hv6hnMUKo5OwPXO54p4rAxW7MWJBCl-1px2qdz49E_1rPhz5o1rt54ZqqcijZrx6tq7kf6yKY2hXqpL9B8tWk-IAnqN98YgWxuOrbHxBKmidQrJNiBOSFjvn9yZBfUxqEIciTedyrj9BJyuFlDlL5iSCcQbLJXUmyEsFeidsOafqe6PXaXwLCsdtkxwkQngMypzeUxZrZiAM2Y4PpbzZdhGqss19-qCvmeq4uFms8_hITmWkbIlQgm9T_nRNaQu94ZTTvU2W1fIxlnO5kma37W6eFZm9xaYuTE2l8W1IvBAeh2ZHv6YyY1wIl9rbbTpn0xXLgtDb9LSmnNku2h1bYf6gn_ajda5SHw67J-f0OOjehB-2ODJG6n6A7o2knz-OSn-Evi_kfE3X8JwjwazoHzLlQAQ2fNM5vcD3fb0FZvV-GPNQIJBskJart2zH2gm6BjrvWO128Z690arfONtlNxWAwAAIkhRkChZAoAEEBCDQAAICEFQAgjWAgAAECCBAAP3-VYDbBgMeIPDsscbx0VWv7-qnnKTT7G7yzP_jfWBb6SJVHxnIFvdmQdSSQk156InI57GUU-55KsbFUuyz-t_n-vTSBQdsm0ZMousz28qXhfqC1C-P6to-fwDXpFo-
link.rule.ids 230,315,783,787,888,4031
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Quenching+Effect+in+an+Optical+Fiber+Type+Small+Size+Dosimeter+Irradiated+with+290+MeV%C2%B7u+-1+Carbon+Ions&rft.jtitle=Journal+of+radiation+protection+and+research&rft.au=Hirata%2C+Yuho&rft.au=Watanabe%2C+Kenichi&rft.au=Uritani%2C+Akira&rft.au=Yamazaki%2C+Atsushi&rft.date=2016&rft.issn=2508-1888&rft.eissn=2466-2461&rft.volume=41&rft.issue=3&rft.spage=222&rft.epage=228&rft.externalDBID=n%2Fa&rft.externalDocID=JAKO201630765904435
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2508-1888&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2508-1888&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2508-1888&client=summon