Test on the Environmental Characteristics of HVDC Overhead Transmission Line Using Reduced-scale Model
HVDC (High Voltage Direct Current) overhead transmission line was considered to prepare the interconnection between northeast Asian countries and inside power systems for the first time in Korea. For HVDC transmission lines, the corona discharge characteristics and space charge of conductors depend...
Saved in:
Published in | Journal of International Council of Electrical Engineering Vol. 1; no. 1; pp. 21 - 27 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | Korean |
Published |
2011
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | HVDC (High Voltage Direct Current) overhead transmission line was considered to prepare the interconnection between northeast Asian countries and inside power systems for the first time in Korea. For HVDC transmission lines, the corona discharge characteristics and space charge of conductors depend on the electric field conditions of the conductor, so transmission line designer have to estimate the electrical environmental effects such as radio, audible, and television noise from any set of conductors. In this paper, test method will be shown using reduced-scale test facilities of HVDC transmission line. |
---|---|
AbstractList | HVDC (High Voltage Direct Current) overhead transmission line was considered to prepare the interconnection between northeast Asian countries and inside power systems for the first time in Korea. For HVDC transmission lines, the corona discharge characteristics and space charge of conductors depend on the electric field conditions of the conductor, so transmission line designer have to estimate the electrical environmental effects such as radio, audible, and television noise from any set of conductors. In this paper, test method will be shown using reduced-scale test facilities of HVDC transmission line. |
Author | Shin, Koo-Yong Lee, Dong-Il Lim, Jae-Seop Kim, Young-Hong |
Author_xml | – sequence: 1 fullname: Shin, Koo-Yong – sequence: 2 fullname: Lim, Jae-Seop – sequence: 3 fullname: Kim, Young-Hong – sequence: 4 fullname: Lee, Dong-Il |
BookMark | eNqNjFFrwjAUhYM40Kn_4b7ssdCkrZpH6RyyOYRRfZWsubXBeAO5mb9_3dgPGBw45-E736MYUyAcialSRZmt9UqNf3eRVbqSE7Fgdp95Wa6GSD0VXYOcIBCkHmFLdxcD3ZCS8VD3Jpo2YXScXMsQOtidnms43DH2aCw00RDf3GAc_ntHCEd2dIEPtF8t2oxb4xHeg0U_Fw-d8YyLv56Jp5dtU--y64_8TJb9-XXzdlC5lFKrMq-WS63z4r_cN7v1SIo |
ContentType | Journal Article |
DBID | JDI |
DEWEY | 621.3 |
DatabaseName | KoreaScience |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
DocumentTitleAlternate | Test on the Environmental Characteristics of HVDC Overhead Transmission Line Using Reduced-scale Model |
EISSN | 2234-8972 |
EndPage | 27 |
ExternalDocumentID | JAKO201119240566990 |
GroupedDBID | .UV 0YH 4.4 5VS 8G5 9ZL ABUWG ACGFS ADBBV ADCVX AFKRA ALMA_UNASSIGNED_HOLDINGS ARCSS AZQEC BCNDV BENPR BPHCQ CCPQU DWQXO EBS EJD GNUQQ GROUPED_DOAJ GUQSH IPNFZ JDI KPIRZ KQ8 KVFHK M2O M4Z M~E OK1 PQQKQ PROAC RDKPK RIG TFMNY TFW |
ID | FETCH-kisti_ndsl_JAKO2011192405669903 |
ISSN | 2233-5951 |
IngestDate | Fri Dec 22 11:59:29 EST 2023 |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Keywords | HVDC overhead transmission line Electric field Down scale test facilities Conductor geometries Electrical environmental effects |
Language | Korean |
LinkModel | OpenURL |
MergedId | FETCHMERGED-kisti_ndsl_JAKO2011192405669903 |
Notes | KISTI1.1003/JNL.JAKO201119240566990 |
OpenAccessLink | http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201119240566990&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
ParticipantIDs | kisti_ndsl_JAKO201119240566990 |
PublicationCentury | 2000 |
PublicationDate | 2011 |
PublicationDateYYYYMMDD | 2011-01-01 |
PublicationDate_xml | – year: 2011 text: 2011 |
PublicationDecade | 2010 |
PublicationTitle | Journal of International Council of Electrical Engineering |
PublicationTitleAlternate | Journal of international council on electrical engineering |
PublicationYear | 2011 |
SSID | ssib044744719 ssj0001255663 |
Score | 3.5676243 |
Snippet | HVDC (High Voltage Direct Current) overhead transmission line was considered to prepare the interconnection between northeast Asian countries and inside power... |
SourceID | kisti |
SourceType | Open Access Repository |
StartPage | 21 |
Title | Test on the Environmental Characteristics of HVDC Overhead Transmission Line Using Reduced-scale Model |
URI | http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201119240566990&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
Volume | 1 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LTwIxEG4IJz0Yn_FJetATqQHaZeFIYA2CyEE0eCL7IhLJ1ghePPDbnWl3ly7iM9lsyNBsyn4f0-mXmSkh5xaEEGXbDpkdukKpVcyrcOCyy13Xq3puTUkDvdtq-150htYwl1uY1SVz79J_X1tX8h9UwQa4YpXsH5BNHwoG-Az4wh0QhvvvMAaXHqv9RWdZsYZ6wEofZpTrH1rNYh9-I7jfQDc1B4xRLMONOUSfM52JFwDYAZsBdqE6KW36Rfya1RKxtt2fqC8cdbKOAt_odphKOU-6a0FXSvYol_Ybfaxzxw3ZXShflrkByqycEmub43UGUQtM7HpqihexW1XeDcISzqx63G02TGyC1ep21j1_YmHiao1FW_cXyLbTXlnm0uTDTqPbx7ng1hPCvyqsx9j8oMTRTfYWTuKOhLDhirvdacnOguGYs5BOHrY0GOdPjJhksE22YjBoQzNjh-Se5S7ZNF76HhkjR6iMKHCEZjhCVzhC5ZgiR2jCEWpyhCJHqOIIzXCEKo7sk4srZ9BsMzXPURTMpqM1b4AfkHwko_CQUCFE3YVlwOPwz-Vl3_MhZi75YmzzigVLwhEpfP-s458GnJANLc3jdUry89e38Axiu7lXUAh8ABY8U-k |
link.rule.ids | 230,315,783,787,888,4033 |
linkProvider | ISSN International Centre |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Test+on+the+Environmental+Characteristics+of+HVDC+Overhead+Transmission+Line+Using+Reduced-scale+Model&rft.jtitle=Journal+of+International+Council+of+Electrical+Engineering&rft.au=Shin%2C+Koo-Yong&rft.au=Lim%2C+Jae-Seop&rft.au=Kim%2C+Young-Hong&rft.au=Lee%2C+Dong-Il&rft.date=2011&rft.issn=2233-5951&rft.eissn=2234-8972&rft.volume=1&rft.issue=1&rft.spage=21&rft.epage=27&rft.externalDBID=n%2Fa&rft.externalDocID=JAKO201119240566990 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2233-5951&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2233-5951&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2233-5951&client=summon |