Phantom dosimetry and evaluation of target localisation for linac based stereotactic radiation
Linear accelerators are widely used for stereotactic radiosurgery and stereotactic radiotherapy. The procedure of stereotactic irradiation involves precise localization of a small intracranial lesion and delivery of single fraction of high doses (SRS) or fractionated treatment (SRT) using multiple c...
Saved in:
Published in | Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143) Vol. 4; pp. 3223 - 3225 vol.4 |
---|---|
Main Authors | , , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
2000
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Linear accelerators are widely used for stereotactic radiosurgery and stereotactic radiotherapy. The procedure of stereotactic irradiation involves precise localization of a small intracranial lesion and delivery of single fraction of high doses (SRS) or fractionated treatment (SRT) using multiple coplanar arcs. A phantom study was carried out to verify the dose delivered to the target and to evaluate the target positioning and localization. The dosimetry was carried out with FBX chemical Dosimeter and with Thermoluminescent dosimeter. The target position was verified by taking radiographs of a radio-opaque target. The results obtained with FBX chemical dosimeter and with TLD were within 5% of the prescribed dose. The estimated positional accuracy of the target was 2 mm. |
---|---|
AbstractList | Linear accelerators are widely used for stereotactic radiosurgery and stereotactic radiotherapy. The procedure of stereotactic irradiation involves precise localization of a small intracranial lesion and delivery of single fraction of high doses (SRS) or fractionated treatment (SRT) using multiple coplanar arcs. A phantom study was carried out to verify the dose delivered to the target and to evaluate the target positioning and localization. The dosimetry was carried out with FBX chemical Dosimeter and with Thermoluminescent dosimeter. The target position was verified by taking radiographs of a radio-opaque target. The results obtained with FBX chemical dosimeter and with TLD were within 5% of the prescribed dose. The estimated positional accuracy of the target was 2 mm. |
Author | Brinda, S. Rajsekhar, S. Faith, R.V. Singh, I.R.R. Ravindran, B.P. |
Author_xml | – sequence: 1 givenname: B.P. surname: Ravindran fullname: Ravindran, B.P. organization: Dept. of Radiat. Oncology, Christian Med. Coll., Hosp., Vellore, India – sequence: 2 givenname: I.R.R. surname: Singh fullname: Singh, I.R.R. – sequence: 3 givenname: S. surname: Brinda fullname: Brinda, S. – sequence: 4 givenname: R.V. surname: Faith fullname: Faith, R.V. – sequence: 5 givenname: S. surname: Rajsekhar fullname: Rajsekhar, S. |
BookMark | eNp9j0FLxDAUhB-6gqv2B-jp_YHWF9t0m6uysh4EQQ-eXJ7tq0bSRJIo7L-3uJ6FgYH5Zg5zAgsfvACcK6qUInN5t76_fqyuiKgypHRnDmCptO7KplX6EAqz6mhW3TatrhczI9OUbbd6PoYipY95R42eGS3h5eGdfQ4TDiHZSXLcIfsB5ZvdF2cbPIYRM8c3yehCz86mfTyGiM567vGVkwyYskQJmftse4w82N_aGRyN7JIUf34KF7frp5tNaUVk-xntxHG33Z-o_4U_2kNK0g |
ContentType | Conference Proceeding |
DBID | 6IE 6IH CBEJK RIE RIO |
DOI | 10.1109/IEMBS.2000.901589 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan (POP) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP) 1998-present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Xplore url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISSN | 1558-4615 |
EndPage | 3225 vol.4 |
ExternalDocumentID | 901589 |
GroupedDBID | 6IE 6IF 6IH 6IL AAJGR ACGFS ADZIZ AFFNX ALMA_UNASSIGNED_HOLDINGS CBEJK CHZPO JC5 M43 OCL RIE RIO RNS |
ID | FETCH-ieee_primary_9015893 |
IEDL.DBID | RIE |
ISBN | 9780780364653 0780364651 |
ISSN | 1094-687X |
IngestDate | Wed Jun 26 19:23:25 EDT 2024 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-ieee_primary_9015893 |
ParticipantIDs | ieee_primary_901589 |
PublicationCentury | 2000 |
PublicationDate | 20000000 |
PublicationDateYYYYMMDD | 2000-01-01 |
PublicationDate_xml | – year: 2000 text: 20000000 |
PublicationDecade | 2000 |
PublicationTitle | Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143) |
PublicationTitleAbbrev | IEMBS |
PublicationYear | 2000 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0000454650 ssj0020051 |
Score | 2.5882413 |
Snippet | Linear accelerators are widely used for stereotactic radiosurgery and stereotactic radiotherapy. The procedure of stereotactic irradiation involves precise... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 3223 |
SubjectTerms | Chemicals Dosimetry Fractionation Head Imaging phantoms Ionizing radiation Lesions Linear accelerators Linear particle accelerator Radiography |
Title | Phantom dosimetry and evaluation of target localisation for linac based stereotactic radiation |
URI | https://ieeexplore.ieee.org/document/901589 |
Volume | 4 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjZ3NS8MwGMZf3E56UedE5wfvwWu79StLrsrGFCYDFXpydEmKImulaw_619s3qZvKDt7aEtqUFp68H88vAFeSDcN6mRE5ni-VEybCd0TiB46qowlPB0k64OR3nt6zyVN4F0dxw9k2XhittWk-0y4dmlq-ymVFqbI-aRcXLWgNhbBWrXU6hUhyjAp0TaxFP5spdIrQYXwYm4idU9GNRV4D3vk-D5pqZz24fzuaXj8Y_4prn_Zr1xUjOuN96-ZeGVYh9Zq8uVW5cOXnH5LjP9_nALobdx_O1rp1CDs668DeDzDhETzPXmhz4SWqfPW61GXxgUmmcIMGxzxF20SORg2bpiCsl8BIFl-JJI8KCcOg89I4sbAgDgIN60JvPHq8mTg02fm7BV7M7TyDY2hneaZPACUTzE-ZVBFLQilSvgg9wSPNI-HrgWan0Nlyg97Wq2ewa-3tlNY4h3ZZVPqiFvpycWk-8Rf5k6b5 |
link.rule.ids | 310,311,783,787,792,793,799,4059,4060,27939,55088 |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PT8IwFH5RPKgXFTGKv3rwusF-tLRXDQQUCImYcJKMtovGsJkxDvrXu9dOUMPB27Y0XZc1-d573_u-AtxI1gqLMIM6ni-VE0bCd0TkB44qsglPB1Hc5Kh3HgxZ9ym8n9BJ6bNttDBaa9N8pl28NFy-SuUSS2UNxC4utmGHYlhhxVqrggp6yTGk6MpsC7eboTpF6DDempicnSPtxqhXWu983wcl31kMbvTag9tHo2Bx7ft-nbtiYKdzYPXcC-NWiN0mb-4yn7ny84-X4z-_6BBqa30fGa2Q6wi2dFKF_R_WhMfwPHrB44XnRKWL17nOsw8SJYqszcFJGhPbRk4MHpZtQaQIggmKfCVBgFQEjRh0mhstFsnQCQGH1aDeaY_vug4udvpuLS-mdp3BCVSSNNGnQCQTzI-ZVJRFoRQxn4We4FRzKnzd1OwMqhsmqG98eg273fGgP-33hg_nsGfF7ljkuIBKni31ZQH7-ezK_O4v6XqqRg |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=Proceedings+of+the+22nd+Annual+International+Conference+of+the+IEEE+Engineering+in+Medicine+and+Biology+Society+%28Cat.+No.00CH37143%29&rft.atitle=Phantom+dosimetry+and+evaluation+of+target+localisation+for+linac+based+stereotactic+radiation&rft.au=Ravindran%2C+B.P.&rft.au=Singh%2C+I.R.R.&rft.au=Brinda%2C+S.&rft.au=Faith%2C+R.V.&rft.date=2000-01-01&rft.pub=IEEE&rft.isbn=9780780364653&rft.issn=1094-687X&rft.eissn=1558-4615&rft.volume=4&rft.spage=3223&rft.epage=3225+vol.4&rft_id=info:doi/10.1109%2FIEMBS.2000.901589&rft.externalDocID=901589 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1094-687X&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1094-687X&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1094-687X&client=summon |