Optimization of anti-corona construction for HV generator and its verification test

An optimized anticorona design (called Coronax) for an HV (high voltage) generator is described which uses digital computation with the Runge-Kutta method instead of a screening test on a large number of specimens. This approach eliminates local overheating, thermal breakdown, and flashover discharg...

Full description

Saved in:
Bibliographic Details
Published inProceedings., Second International Conference on Properties and Applications of Dielectric Materials pp. 662 - 666 vol.2
Main Authors Shangchun Liu, Xiuhua Ren, Jingfu Li
Format Conference Proceeding
LanguageEnglish
Published IEEE 1988
Subjects
Online AccessGet full text

Cover

Loading…
Abstract An optimized anticorona design (called Coronax) for an HV (high voltage) generator is described which uses digital computation with the Runge-Kutta method instead of a screening test on a large number of specimens. This approach eliminates local overheating, thermal breakdown, and flashover discharge along or over the surface of the Coronax during a 1-min. Hi-pot test. Also presented are results of a verification test.< >
AbstractList An optimized anticorona design (called Coronax) for an HV (high voltage) generator is described which uses digital computation with the Runge-Kutta method instead of a screening test on a large number of specimens. This approach eliminates local overheating, thermal breakdown, and flashover discharge along or over the surface of the Coronax during a 1-min. Hi-pot test. Also presented are results of a verification test.< >
Author Jingfu Li
Xiuhua Ren
Shangchun Liu
Author_xml – sequence: 1
  surname: Shangchun Liu
  fullname: Shangchun Liu
  organization: Harbin Electr. Machinery Works, China
– sequence: 2
  surname: Xiuhua Ren
  fullname: Xiuhua Ren
  organization: Harbin Electr. Machinery Works, China
– sequence: 3
  surname: Jingfu Li
  fullname: Jingfu Li
BookMark eNp9jr0KwjAURjPo4N8DdMsLtBoqko5SlTqIguJaQryRC_amJFdBn16pzk6HjwMfZyh65AmESNQsU2pWTLflYbnaZarQOsv1XC8G4rhvGRt8GUZP0jtpiDG1Pngy0nqKHO62c84HWZ3lFQiC4c8wdJHIUT4goEP7fWCIPBZ9Z24RJj-ORLJZn8oqRQCo24CNCc-6C8j_uTcmeDwl
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/ICPADM.1988.38486
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Xplore
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Xplore
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Physics
EndPage 666 vol.2
ExternalDocumentID 38486
GroupedDBID 6IE
6IL
CBEJK
RIE
RIL
ID FETCH-ieee_primary_384863
IEDL.DBID RIE
IngestDate Thu Jun 29 18:09:43 EDT 2023
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-ieee_primary_384863
ParticipantIDs ieee_primary_38486
PublicationCentury 1900
PublicationDate 19880000
PublicationDateYYYYMMDD 1988-01-01
PublicationDate_xml – year: 1988
  text: 19880000
PublicationDecade 1980
PublicationTitle Proceedings., Second International Conference on Properties and Applications of Dielectric Materials
PublicationTitleAbbrev ICPADM
PublicationYear 1988
Publisher IEEE
Publisher_xml – name: IEEE
Score 2.4207997
Snippet An optimized anticorona design (called Coronax) for an HV (high voltage) generator is described which uses digital computation with the Runge-Kutta method...
SourceID ieee
SourceType Publisher
StartPage 662
SubjectTerms Conductivity
Design optimization
Differential equations
Physics
Power engineering and energy
Power generation
Power systems
System testing
Systems engineering and theory
Voltage
Title Optimization of anti-corona construction for HV generator and its verification test
URI https://ieeexplore.ieee.org/document/38486
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3dS8MwED_cQPBJpxOnU_Lga7vapm36OKajCtOBH-xtJOlVhtgO2r3413tJi8OPB99CSMKR5Li75H6_A7gMvTz2yRF1JMbocJVQS0aZgxRf05XyRSYNwHl2H6XP_G4RLlqaHIuFQUSbfIauadq__KzUG_NUNgoEF1EHOsLzG6RW-0155SWj28l8fD1zKYYWrh33rVyKtRbT_absUGVJBk2SyJu7qZWrP35QMP5PkAPob1F5bP5lb3qwg8Uh7NoUTl0dweMDaf97C6tkZc5oz1aONgwFkulyyxTLyE9l6Qt7tYzTFHPTyIyt6orRtTaZQ80K5IPWfRhMb54mqWOEW64bZoqllSs4hm5RFngCLPYUT0jjJLkJpKlChYrnKghkEurY4ziA3u_5p391nsGe2drm8WEIXRIZz8kc1-rCnsQnY86TLQ
link.rule.ids 310,311,786,790,795,796,802,4069,4070,27956,55107
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8MwDLZgCMEJBkOMZw5c24U1fR3RYOpgHZMYaLcqSdNpQrRI7S78epy0YuJx4BZFSWQlsWwn_j4DXLk08_voiFpc-cpiIsQW91JLYXyNV6ofpFwDnOOJFz2z-7k7b2hyDBZGKWWSz5Stm-YvPy3kSj-V9ZyABd4mbKGVp36N1Wo-Kq9p2BsNpje3sY1RdGCbkd8Kphh7MdyrCw-VhmZQp4m82qtK2PLjBwnj_0TZh84al0emXxanDRsqP4Btk8Qpy0N4ekT9f2uAlaTICO7a0pKao4ATWay5Ygl6qiR6IQvDOY1RN45MybIqCV5snTtUr4BeaNWB7vBuNogsLVzyXnNTJEYu5whaeZGrYyA-FSxEnePoKKCuBsIVLBOOw0NX-pSpLrR_zz_5q_MSdqJZPE7Go8nDKezqba6fIs6gheKrczTOlbgwp_IJTkmWgQ
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=Proceedings.%2C+Second+International+Conference+on+Properties+and+Applications+of+Dielectric+Materials&rft.atitle=Optimization+of+anti-corona+construction+for+HV+generator+and+its+verification+test&rft.au=Shangchun+Liu&rft.au=Xiuhua+Ren&rft.au=Jingfu+Li&rft.date=1988-01-01&rft.pub=IEEE&rft.spage=662&rft.epage=666+vol.2&rft_id=info:doi/10.1109%2FICPADM.1988.38486&rft.externalDocID=38486