Uncertainty analysis of measurement error in calculating vascular input impedance: how many harmonics can be resolved?
Vascular input impedance represents the hydraulic load seen by the ejecting ventricle and is represented by magnitude and phase components in the frequency domain derived from Fast Fourier Transform (FFT) of instantaneous vascular pressure and flow measurements. The resulting spectra consists of a m...
Saved in:
Published in | Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology Vol. 2; pp. 1319 - 1320 vol.2 |
---|---|
Main Authors | , , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
2002
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Vascular input impedance represents the hydraulic load seen by the ejecting ventricle and is represented by magnitude and phase components in the frequency domain derived from Fast Fourier Transform (FFT) of instantaneous vascular pressure and flow measurements. The resulting spectra consists of a mean or DC component and magnitude and phase information at harmonics of the fundamental frequency. The objective of this study was to determine how many harmonics could be faithfully reproduced as a function of measurement error associated with the instantaneous pressure and flow recordings using uncertainty analysis. Input impedance and uncertainty analysis algorithms were developed in Matlab. Simulated vascular pressure and flow waveforms were constructed by summing a series of sine waves of varying amplitude and phase to verify accuracy of the impedance and uncertainty m-files. Random normally distributed noise was injected into the simulated waveforms and a Monte Carlo analysis performed to verify the injected 'noise' which fell within the bounded limits. Using aortic pressure and flow data obtained experimentally in an acute animal model, the uncertainty error associated with pressure, flow, and sampling time errors for up to ten harmonics was determined. These results indicate that given high-fidelity data, the DC and up to six harmonics can be faithfully resolved. |
---|---|
AbstractList | Vascular input impedance represents the hydraulic load seen by the ejecting ventricle and is represented by magnitude and phase components in the frequency domain derived from Fast Fourier Transform (FFT) of instantaneous vascular pressure and flow measurements. The resulting spectra consists of a mean or DC component and magnitude and phase information at harmonics of the fundamental frequency. The objective of this study was to determine how many harmonics could be faithfully reproduced as a function of measurement error associated with the instantaneous pressure and flow recordings using uncertainty analysis. Input impedance and uncertainty analysis algorithms were developed in Matlab. Simulated vascular pressure and flow waveforms were constructed by summing a series of sine waves of varying amplitude and phase to verify accuracy of the impedance and uncertainty m-files. Random normally distributed noise was injected into the simulated waveforms and a Monte Carlo analysis performed to verify the injected 'noise' which fell within the bounded limits. Using aortic pressure and flow data obtained experimentally in an acute animal model, the uncertainty error associated with pressure, flow, and sampling time errors for up to ten harmonics was determined. These results indicate that given high-fidelity data, the DC and up to six harmonics can be faithfully resolved. |
Author | Wheeler, B. Jorgenson, J. Koenig, S.C. Schroeder, M.J. Ewert, D.L. |
Author_xml | – sequence: 1 givenname: S.C. surname: Koenig fullname: Koenig, S.C. organization: Jewish Hosp. Cardiothoracic Surg. Res. Inst., Louisville Univ., KY, USA – sequence: 2 givenname: M.J. surname: Schroeder fullname: Schroeder, M.J. organization: Jewish Hosp. Cardiothoracic Surg. Res. Inst., Louisville Univ., KY, USA – sequence: 3 givenname: B. surname: Wheeler fullname: Wheeler, B. – sequence: 4 givenname: J. surname: Jorgenson fullname: Jorgenson, J. – sequence: 5 givenname: D.L. surname: Ewert fullname: Ewert, D.L. |
BookMark | eNp9T8tOwzAQtKBItNAfgMv-QIqdOi8uSKAiOHACJG7Vkm6pkb2O7CQof99E6pm9zEsz0i7EjD2TEDdKrpSS1d3r5u3xfZVKmU4617I4E3OVZWWic5Wdi4UsSrkucpVWszGQlU7ysvi6FMsYf-V4OlNaV3PRf3JNoUXD7QDIaIdoIvg9OMLYBXLELVAIPoBhqNHWncXW8A_0GCc--U3XgnEN7XAcu4eD_wOHPMABg_Ns6jgWGb4JAkVve9o9XIuLPdpIyxNeidvnzcfTS2KIaNsE4zAM29Nr6__TIxMlU3A |
ContentType | Conference Proceeding |
DBID | 6IE 6IH CBEJK RIE RIO |
DOI | 10.1109/IEMBS.2002.1106407 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan (POP) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library Online IEEE Proceedings Order Plans (POP) 1998-present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library Online url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISSN | 1558-4615 |
EndPage | 1320 vol.2 |
ExternalDocumentID | 1106407 |
Genre | orig-research |
GroupedDBID | 6IE 6IF 6IH 6IL AAJGR ACGFS ADZIZ AFFNX ALMA_UNASSIGNED_HOLDINGS CBEJK CHZPO JC5 M43 OCL RIE RIO RNS |
ID | FETCH-ieee_primary_11064073 |
IEDL.DBID | RIE |
ISBN | 0780376129 9780780376120 |
ISSN | 1094-687X |
IngestDate | Wed Jun 26 19:39:51 EDT 2024 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-ieee_primary_11064073 |
ParticipantIDs | ieee_primary_1106407 |
PublicationCentury | 2000 |
PublicationDate | 20020000 |
PublicationDateYYYYMMDD | 2002-01-01 |
PublicationDate_xml | – year: 2002 text: 20020000 |
PublicationDecade | 2000 |
PublicationTitle | Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology |
PublicationTitleAbbrev | IEMBS |
PublicationYear | 2002 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0000451449 ssj0020051 |
Score | 2.6438503 |
Snippet | Vascular input impedance represents the hydraulic load seen by the ejecting ventricle and is represented by magnitude and phase components in the frequency... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 1319 |
SubjectTerms | Error analysis Fast Fourier transforms Fluid flow measurement Frequency domain analysis Frequency measurement Harmonic analysis Impedance measurement Measurement errors Phase measurement Pressure measurement |
Title | Uncertainty analysis of measurement error in calculating vascular input impedance: how many harmonics can be resolved? |
URI | https://ieeexplore.ieee.org/document/1106407 |
Volume | 2 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEJ4AJ734AKOiZg4ebWno0ocXEw0ETTAmSsKNdNtdJUpLaovRX-_stgU1HLy1m74ms93ZmfnmG4DzkLQqpG0bThDaBotYYJCdcQ0_Cnqew32XS1UoPLp3hmN2N-lNanCxqoURQmjwmTDVoc7lR0mYq1BZh0yVyjvVoe76TlGrtYqnKJ4UplyJ0tlSs01nOn1mOJ470S67Z9H_RBauZN6pzq2qmsbyO7f90fWjhi6Y5et-9V3RZmewA6Pqgwu0yauZZ9wMv_5wOf5Xol1orQv88GFluvagJuJ92P7BTdiE5Zgu0nCB7BODkroEE4nzdVQRRZomKc5iJE2HuhFY_IwVuJXGF3mGM9qYR2puXeJL8oFzWn1Q8WUrTt53ujFGLpCc_uRtKaKrFrQH_aeboaGkmC4KLoxpKYB9AI04icUhoMVlTzKH0-plKfCqL5mIhHRdL5Bd2RVH0Nz0hOPNw23Y0v1XdNDjBBpZmotT2gZk_Ezr_xt0n7Go |
link.rule.ids | 309,310,780,784,789,790,796,4050,4051,27925,54758 |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEJ4gHtSLDzAqPubg0ZaGbl9eTDQQUEpMhIQb6WNXidKS2mL017u7bUENB2_tpq_JTnd2Zr75BuAy4LNKma4rphfoCgmJp3A7YylO6Bm26TuWz0ShsDswuyNyPzbGFbha1sJQSiX4jKriUObywzjIRKisyU2VyDttwKZB-D43r9ZaRlQEUwoRzkThbgl9k7lOhyimbY2l025r_I_iNq7g3inPtbKeRnOavbZ7-yTBC2rxwl-dV6Th6eyCW35yjjd5VbPUV4OvP2yO_5VpD-qrEj98XBqvfajQ6AB2frAT1mAx4hdJwED6iV5BXoIxw9kqrog0SeIEpxHyuQ5kK7DoGUt4Kx-fZylO-dY8FNp1jS_xB874-oOCMVuw8r7zGyP0KXK3P35b0PCmDo1Oe3jXVYQUk3nOhjEpBNAPoRrFET0C1HxmMGL6fP3SBHzVYYSGlFmW7bEWa9FjqK17wsn64QvY6g7d_qTfGzw0YFt2Y5EhkFOopklGz_imIPXPpS58A_3jtPs |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=Proceedings+of+the+Second+Joint+24th+Annual+Conference+and+the+Annual+Fall+Meeting+of+the+Biomedical+Engineering+Society%5D+%5BEngineering+in+Medicine+and+Biology&rft.atitle=Uncertainty+analysis+of+measurement+error+in+calculating+vascular+input+impedance%3A+how+many+harmonics+can+be+resolved%3F&rft.au=Koenig%2C+S.C.&rft.au=Schroeder%2C+M.J.&rft.au=Wheeler%2C+B.&rft.au=Jorgenson%2C+J.&rft.date=2002-01-01&rft.pub=IEEE&rft.isbn=9780780376120&rft.issn=1094-687X&rft.eissn=1558-4615&rft.volume=2&rft.spage=1319&rft.epage=1320+vol.2&rft_id=info:doi/10.1109%2FIEMBS.2002.1106407&rft.externalDocID=1106407 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1094-687X&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1094-687X&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1094-687X&client=summon |