Development and single-laboratory validation of an HPLC method for the determination of cyclamate sweetener in foodstuffs

A method for the determination of cyclamate has been developed and single-laboratory validated for a range of foodstuffs including carbonated and fruit-juice drinks, fruit preserves, spreads, and dairy desserts. The method uses the peroxide oxidation of cyclamate to cyclohexylamine followed by deriv...

Full description

Saved in:
Bibliographic Details
Published inFood additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment Vol. 26; no. 5; pp. 614 - 622
Main Authors Scotter, M.J, Castle, L, Roberts, D.P.T, MacArthur, R, Brereton, P.A, Hasnip, S.K, Katz, N
Format Publication
LanguageEnglish
Published 2009
Subjects
Online AccessGet more information

Cover

Loading…
Abstract A method for the determination of cyclamate has been developed and single-laboratory validated for a range of foodstuffs including carbonated and fruit-juice drinks, fruit preserves, spreads, and dairy desserts. The method uses the peroxide oxidation of cyclamate to cyclohexylamine followed by derivatization with trinitrobenzenesulfonic acid and analysis by a modified reversed-phase high-performance liquid chromatography-ultraviolet light (HPLC-UV). Cycloheptylamine is used as an internal standard. The limits of detection were in the range 1-20 mg kg-1 and the analysis was linear up to 1300 mg kg-1 cyclamic acid in foods and up to 67 mg l-1 in beverages. Analytical recovery was between 82% and 123%, and results were recovery corrected. Precision was within experimentally predicted levels for all of the matrices tested and Horrat values for the combined standard uncertainty associated with the measurement of cyclamate between 0.4 (water-based drinks) and 1.7 (spreads). The method was used successfully to test three soft drink samples for homogeneity before analytical performance assessment. The method is recommended for use in monitoring compliance and for formal testing by collaborative trial.
AbstractList A method for the determination of cyclamate has been developed and single-laboratory validated for a range of foodstuffs including carbonated and fruit-juice drinks, fruit preserves, spreads, and dairy desserts. The method uses the peroxide oxidation of cyclamate to cyclohexylamine followed by derivatization with trinitrobenzenesulfonic acid and analysis by a modified reversed-phase high-performance liquid chromatography-ultraviolet light (HPLC-UV). Cycloheptylamine is used as an internal standard. The limits of detection were in the range 1-20 mg kg-1 and the analysis was linear up to 1300 mg kg-1 cyclamic acid in foods and up to 67 mg l-1 in beverages. Analytical recovery was between 82% and 123%, and results were recovery corrected. Precision was within experimentally predicted levels for all of the matrices tested and Horrat values for the combined standard uncertainty associated with the measurement of cyclamate between 0.4 (water-based drinks) and 1.7 (spreads). The method was used successfully to test three soft drink samples for homogeneity before analytical performance assessment. The method is recommended for use in monitoring compliance and for formal testing by collaborative trial.
Author Roberts, D.P.T
Castle, L
Brereton, P.A
Katz, N
MacArthur, R
Scotter, M.J
Hasnip, S.K
Author_xml – sequence: 1
  fullname: Scotter, M.J
– sequence: 2
  fullname: Castle, L
– sequence: 3
  fullname: Roberts, D.P.T
– sequence: 4
  fullname: MacArthur, R
– sequence: 5
  fullname: Brereton, P.A
– sequence: 6
  fullname: Hasnip, S.K
– sequence: 7
  fullname: Katz, N
BookMark eNqFyr8OgjAQgHEGHfz3DN4LkCAm6I4aBgcTdSYnvUKT9s60FcPby2Bcnb7h-82TCQvTLBkO1JOVpyOOgKwgGG4tpRYf4jGKH6BHaxRGIwyiRwPV5VyCo9iJAi0eYkegKJJ3hn-uGRqLDiNBeNM4mTwYHr2oEF9ah2Uy1WgDrb5dJOvT8VZWqUapsfUm1Pdrnm222aYosny_y_-LDzavRfY
ContentType Publication
DBID FBQ
DatabaseName AGRIS
DatabaseTitleList
Database_xml – sequence: 1
  dbid: FBQ
  name: AGRIS
  url: http://www.fao.org/agris/Centre.asp?Menu_1ID=DB&Menu_2ID=DB1&Language=EN&Content=http://www.fao.org/agris/search?Language=EN
  sourceTypes: Publisher
DeliveryMethod no_fulltext_linktorsrc
EndPage 622
ExternalDocumentID US201301660287
GroupedDBID FBQ
ID FETCH-fao_agris_US2013016602872
IngestDate Tue Nov 07 23:17:58 EST 2023
IsPeerReviewed false
IsScholarly false
Issue 5
Language English
LinkModel OpenURL
MergedId FETCHMERGED-fao_agris_US2013016602872
Notes http://www.metapress.com/openurl.asp?genre=journal&issn=0265-203X
ParticipantIDs fao_agris_US201301660287
PublicationCentury 2000
PublicationDate 2009
PublicationDateYYYYMMDD 2009-01-01
PublicationDate_xml – year: 2009
  text: 2009
PublicationDecade 2000
PublicationTitle Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment
PublicationYear 2009
Score 2.720452
Snippet A method for the determination of cyclamate has been developed and single-laboratory validated for a range of foodstuffs including carbonated and fruit-juice...
SourceID fao
SourceType Publisher
StartPage 614
SubjectTerms artificial sweeteners
cyclamic acid
food additives
foods
new methods
oxidation
oxidative stability
quantitative analysis
reversed-phase high performance liquid chromatography
sodium cyclamate
validity
Title Development and single-laboratory validation of an HPLC method for the determination of cyclamate sweetener in foodstuffs
Volume 26
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnZ3PT8IwFMcb1IueNGrwdw_eCMsG29iOSCTEiMEICTdStlZJDDOjRPHmf-57a9mKSqJelmY0HfBpu9e-73sl5NL2waYPbA8WORiS4_EaBis7VVgLMcZsJoLsFIXund8ZuDdDb1gqfZjRJXJsRe8_xpX8hyrcA64YJfsHsnmjcAPKwBeuQBiuv2JsKH4yJwCu-595VYNF7zk8bRLnViGM5U7vtqWPjc4VhvFSErOsFy0i6ChghVZmrxytao6idaifxDM5F2JmmrRtzIuMsiSZZbDFroT6d6Y1NhYYqamsNJVvX58upzSjKh0KlrVgHov87SXBXcusoUz4zvLkoYXXKJH6QJGulW90txi6rItIChXdxlOpVgpWz8oF4V0WNVP5NE8LyeRy5yM0dj701K2C7XUX9Yx52FeRqfqV7qvQ5y-JtQcPNXTbOr4PNlZjg2w0Apwo21f3YGcIZtoZ_V2yY2yj7pESn-6ThUGZAmX6jTItKNNEQB2KlKmiTIEyBcp0hTLWyynTnDKdTGlB-YBctK_7rU4VvuaIPQKM0eqvqR2SzWky5WVCWd0OY1v4MCQjl9v10I4ctxG4bsgcIQQ_IuV1rRyv_-iEbBdITsmWgCHFz8A-k-Pz7D_8BDACSe8
link.rule.ids 783
linkProvider FAO Food and Agriculture Organization of the United Nations
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Development+and+single-laboratory+validation+of+an+HPLC+method+for+the+determination+of+cyclamate+sweetener+in+foodstuffs&rft.jtitle=Food+additives+%26+contaminants.+Part+A%2C+Chemistry%2C+analysis%2C+control%2C+exposure+%26+risk+assessment&rft.au=Scotter%2C+M.J&rft.au=Castle%2C+L&rft.au=Roberts%2C+D.P.T&rft.au=MacArthur%2C+R&rft.date=2009-01-01&rft.volume=26&rft.issue=5&rft.spage=614&rft.epage=622&rft.externalDocID=US201301660287