USING HOT WIRE TECHNIQUE FOR MEASURING THERMAL CONDUCTIVITY OF INFUSIONS OF ORGANIC AND CONVENTIONAL COFFEE

The technique of hot wire, a versatile method of low cost and high accuracy for measuring the thermal conductivity of fluids through the increasing temperature of a wire that is immersed into the liquid and between its ends a potential difference is abruptly applied. Using well-known conductivity li...

Full description

Saved in:
Bibliographic Details
Published inRevista de la Facultad de Ciencias Vol. 5; no. 2; pp. 105 - 113
Main Authors Fernando Gordillo-Delgado, Diego F. Valencia-Grisales, Jesús Plazas-Saldaña
Format Journal Article
LanguageSpanish
Published Universidad Nacional de Colombia, sede Medellín 01.07.2016
Subjects
Online AccessGet full text

Cover

Loading…
Abstract The technique of hot wire, a versatile method of low cost and high accuracy for measuring the thermal conductivity of fluids through the increasing temperature of a wire that is immersed into the liquid and between its ends a potential difference is abruptly applied. Using well-known conductivity liquids: water, ethylene glycol and glycerine, the system was tested and calibrated. In this work, this procedure was used to measure the thermal conductivity of the infusion samples of organic and conventional coffee. The same roast degree of the beans was verified with a colorimeter and the preparation was made by pressing 22g of coffee powder in 110mL of water. The obtained data were subjected to Analysis of Variance (ANOVA) and this confirmed that the differences in the thermophysical parameter in the two samples are significant with a confidence level of 95\%. On this way, it was proved that the thermal conductivity value of the coffee infusion allows differentiate between organic and conventional coffee.
AbstractList The technique of hot wire, a versatile method of low cost and high accuracy for measuring the thermal conductivity of fluids through the increasing temperature of a wire that is immersed into the liquid and between its ends a potential difference is abruptly applied. Using well-known conductivity liquids: water, ethylene glycol and glycerine, the system was tested and calibrated. In this work, this procedure was used to measure the thermal conductivity of the infusion samples of organic and conventional coffee. The same roast degree of the beans was verified with a colorimeter and the preparation was made by pressing 22g of coffee powder in 110mL of water. The obtained data were subjected to Analysis of Variance (ANOVA) and this confirmed that the differences in the thermophysical parameter in the two samples are significant with a confidence level of 95\%. On this way, it was proved that the thermal conductivity value of the coffee infusion allows differentiate between organic and conventional coffee.
Author Jesús Plazas-Saldaña
Diego F. Valencia-Grisales
Fernando Gordillo-Delgado
Author_xml – sequence: 1
  fullname: Fernando Gordillo-Delgado
  organization: Universidad del Quindío
– sequence: 2
  fullname: Diego F. Valencia-Grisales
– sequence: 3
  fullname: Jesús Plazas-Saldaña
BookMark eNqtjOFOgzAAhBszE1H3DvUBwLa0MH4SVkYTVyKUqb9IV1uDTjBglvj2jsVH8Nfl7r67a7Doh94CcIdRgBml0f1oj4HTJjCd7U1wZD0JIrRaJRfAIyGLfcZosgAewgT7MY2fr8Bymro9ojRmCaLEAx9NLeQGFqWCT6LiUPGskOKx4TAvK7jlad1UM6AKXm3TB5iVct1kSuyEeoFlDoXMTw-lrGdTVptUigymcj2DOy7VqTqv8pzzW3Dp9GGyyz-9ASLnKiv810G_t19j96nHn3bQXXsOhvGt1eN3Zw62RZbFFBOn9yGjzLkkcpEhNGTGJQgbFv7n1y_smmW3
ContentType Journal Article
DBID DOA
DOI 10.15446/rev.fac.cienc.v5n2.60889
DatabaseName DOAJ Directory of Open Access Journals
DatabaseTitleList
Database_xml – sequence: 1
  dbid: DOA
  name: DOAJ Directory of Open Access Journals
  url: https://www.doaj.org/
  sourceTypes: Open Website
DeliveryMethod fulltext_linktorsrc
Discipline Sciences (General)
EISSN 2357-5549
EndPage 113
ExternalDocumentID oai_doaj_org_article_0e57412fab3545ff96f6c2435cf901c5
GroupedDBID ADBBV
ALMA_UNASSIGNED_HOLDINGS
BCNDV
GROUPED_DOAJ
M~E
OK1
ID FETCH-doaj_primary_oai_doaj_org_article_0e57412fab3545ff96f6c2435cf901c53
IEDL.DBID DOA
ISSN 0121-747X
IngestDate Tue Oct 22 15:15:39 EDT 2024
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 2
Language Spanish
LinkModel DirectLink
MergedId FETCHMERGED-doaj_primary_oai_doaj_org_article_0e57412fab3545ff96f6c2435cf901c53
OpenAccessLink https://doaj.org/article/0e57412fab3545ff96f6c2435cf901c5
ParticipantIDs doaj_primary_oai_doaj_org_article_0e57412fab3545ff96f6c2435cf901c5
PublicationCentury 2000
PublicationDate 2016-07-01
PublicationDateYYYYMMDD 2016-07-01
PublicationDate_xml – month: 07
  year: 2016
  text: 2016-07-01
  day: 01
PublicationDecade 2010
PublicationTitle Revista de la Facultad de Ciencias
PublicationYear 2016
Publisher Universidad Nacional de Colombia, sede Medellín
Publisher_xml – name: Universidad Nacional de Colombia, sede Medellín
SSID ssib044759042
ssib045315704
ssj0002140192
Score 4.019307
Snippet The technique of hot wire, a versatile method of low cost and high accuracy for measuring the thermal conductivity of fluids through the increasing temperature...
SourceID doaj
SourceType Open Website
StartPage 105
SubjectTerms alambre caliente
ANOVA
café orgánico
Conductividad térmica
Title USING HOT WIRE TECHNIQUE FOR MEASURING THERMAL CONDUCTIVITY OF INFUSIONS OF ORGANIC AND CONVENTIONAL COFFEE
URI https://doaj.org/article/0e57412fab3545ff96f6c2435cf901c5
Volume 5
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV3PT4MwFG7MDsaLcf6Iv1MTD3pgQyhsOyIro0YgTpjzRDpsLybTuOnRv933KDHz5EEvJCUEykv7vu81L99HyLmvlO8qNrDQdcBiwGgt6djScmaAbrKnet4THugnqR8X7GbqTVesvrAnzMgDm8B1beUB6DlazlwAe60HvvYrB0C-0gBllVEvvfJWiilYSbWKnc2-gZvBSvN6TeGBOdrBuqJ2TEZNMws49XSdnNV2QFAfddH-RcP_1Nur8-HNnY6P_UA_hP1rBIq2yGZDHWlgptwma2qxTdrN5lzQi0ZB-nKHPKOZxojGWU4fxJjTnIdxKu4KTqHmowmHXIpNEDSP-TgJbmmYpcMizMVE5I80i6hIowKT7D0OsvEoSEVIg3SID054avRzYRBFnO8SEfE8jC2ccvlqxCtKlJOub0CQyybI5W9BdvdIa_4yV_uEIn_pa9WHTMmYZraECndQ9W3p6oopKQ_I9d-_d_gfLzkiG8BufNNbe0xay7d3dQIMYjk7rRcLXJNP_gU1hLtb
link.rule.ids 315,786,790,870,2115,27955,27956
linkProvider Directory of Open Access Journals
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=USING+HOT+WIRE+TECHNIQUE+FOR+MEASURING+THERMAL+CONDUCTIVITY+OF+INFUSIONS+OF+ORGANIC+AND+CONVENTIONAL+COFFEE&rft.jtitle=Revista+de+la+Facultad+de+Ciencias&rft.au=Fernando+Gordillo-Delgado&rft.au=Diego+F.+Valencia-Grisales&rft.au=Jes%C3%BAs+Plazas-Salda%C3%B1a&rft.date=2016-07-01&rft.pub=Universidad+Nacional+de+Colombia%2C+sede+Medell%C3%ADn&rft.issn=0121-747X&rft.eissn=2357-5549&rft.volume=5&rft.issue=2&rft.spage=105&rft.epage=113&rft_id=info:doi/10.15446%2Frev.fac.cienc.v5n2.60889&rft.externalDBID=DOA&rft.externalDocID=oai_doaj_org_article_0e57412fab3545ff96f6c2435cf901c5
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0121-747X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0121-747X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0121-747X&client=summon