A triaxial vectorization technique for a single-beam zero-field atomic magnetometer to suppress cross-axis projection error

Zero-field optically pumped magnetometers (OPMs) have emerged as an important technology for biomagnetism due to their ulta-sensitive performance, contained within a non-cryogenic small-scale sensor-head. The compactness of such OPMs is often achieved through simplified detection schemes, which typi...

Full description

Saved in:
Bibliographic Details
Main Authors Dawson, Rach, Mrozowski, Marcin S, Hunter, Dominic, O'Dwyer, Carolyn, Riis, Erling, Griffin, Paul. F, Ingleby, Stuart
Format Journal Article
LanguageEnglish
Published 23.08.2024
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Zero-field optically pumped magnetometers (OPMs) have emerged as an important technology for biomagnetism due to their ulta-sensitive performance, contained within a non-cryogenic small-scale sensor-head. The compactness of such OPMs is often achieved through simplified detection schemes, which typically provide only single-axis magnetic field information. However, multi-axis static magnetic fields on non-measurement axes cause a systematic error that manifests as amplitude and phase errors across the measurement axis. Here we present a triaxial operational technique for a compact zero-field OPM which suppresses multi-axis systematic errors through simultaneous measurement and closed-loop active control of the static magnetic fields across all axes. The demonstrated technique requires magnetic modulation across two axes while providing static field information for all three axes. We demonstrate this technique on a rubidium laboratory-based zero-field magnetometer, achieving a bandwidth of 380 Hz with sensitivities of $<25$ fT/$\sqrt{\rm{Hz}}$ across both transverse axes and $65$ fT/$\sqrt{\rm{Hz}}$ along the beam axis. Using the proposed triaxial technique, we demonstrate precise tracking of a 2 Hz triaxial vector test signal and suppression of systematic cross-axis projection errors over an extended period, $\simeq20$~min.
AbstractList Zero-field optically pumped magnetometers (OPMs) have emerged as an important technology for biomagnetism due to their ulta-sensitive performance, contained within a non-cryogenic small-scale sensor-head. The compactness of such OPMs is often achieved through simplified detection schemes, which typically provide only single-axis magnetic field information. However, multi-axis static magnetic fields on non-measurement axes cause a systematic error that manifests as amplitude and phase errors across the measurement axis. Here we present a triaxial operational technique for a compact zero-field OPM which suppresses multi-axis systematic errors through simultaneous measurement and closed-loop active control of the static magnetic fields across all axes. The demonstrated technique requires magnetic modulation across two axes while providing static field information for all three axes. We demonstrate this technique on a rubidium laboratory-based zero-field magnetometer, achieving a bandwidth of 380 Hz with sensitivities of $<25$ fT/$\sqrt{\rm{Hz}}$ across both transverse axes and $65$ fT/$\sqrt{\rm{Hz}}$ along the beam axis. Using the proposed triaxial technique, we demonstrate precise tracking of a 2 Hz triaxial vector test signal and suppression of systematic cross-axis projection errors over an extended period, $\simeq20$~min.
Author Hunter, Dominic
O'Dwyer, Carolyn
Dawson, Rach
Griffin, Paul. F
Ingleby, Stuart
Riis, Erling
Mrozowski, Marcin S
Author_xml – sequence: 1
  givenname: Rach
  surname: Dawson
  fullname: Dawson, Rach
– sequence: 2
  givenname: Marcin S
  surname: Mrozowski
  fullname: Mrozowski, Marcin S
– sequence: 3
  givenname: Dominic
  surname: Hunter
  fullname: Hunter, Dominic
– sequence: 4
  givenname: Carolyn
  surname: O'Dwyer
  fullname: O'Dwyer, Carolyn
– sequence: 5
  givenname: Erling
  surname: Riis
  fullname: Riis, Erling
– sequence: 6
  givenname: Paul. F
  surname: Griffin
  fullname: Griffin, Paul. F
– sequence: 7
  givenname: Stuart
  surname: Ingleby
  fullname: Ingleby, Stuart
BackLink https://doi.org/10.48550/arXiv.2408.12994$$DView paper in arXiv
BookMark eNqFjjsOwkAMRLeAgt8BqPAFEhJIpFAiBOIA9JEJDhgl6-BdEJ_LExA91Uwxmvf6pmPFkjHjOAqTLE2jKeqdb-EsibIwni0WSc-8luCV8c5YwY0KL8pP9CwWPBUny5crQSkKCI7tsaJgT1jDk1SCkqk6AHqpuYAaj5baSp4UvIC7No2Sc1CoOBe0AAeNyrlFfM5JVXRouiVWjka_HJjJZr1bbYOvZt4o16iP_KObf3Xn_xdvHl1P1Q
ContentType Journal Article
Copyright http://creativecommons.org/licenses/by/4.0
Copyright_xml – notice: http://creativecommons.org/licenses/by/4.0
DBID GOX
DOI 10.48550/arxiv.2408.12994
DatabaseName arXiv.org
DatabaseTitleList
Database_xml – sequence: 1
  dbid: GOX
  name: arXiv.org
  url: http://arxiv.org/find
  sourceTypes: Open Access Repository
DeliveryMethod fulltext_linktorsrc
ExternalDocumentID 2408_12994
GroupedDBID GOX
ID FETCH-arxiv_primary_2408_129943
IEDL.DBID GOX
IngestDate Tue Aug 27 12:20:13 EDT 2024
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-arxiv_primary_2408_129943
OpenAccessLink https://arxiv.org/abs/2408.12994
ParticipantIDs arxiv_primary_2408_12994
PublicationCentury 2000
PublicationDate 2024-08-23
PublicationDateYYYYMMDD 2024-08-23
PublicationDate_xml – month: 08
  year: 2024
  text: 2024-08-23
  day: 23
PublicationDecade 2020
PublicationYear 2024
Score 3.8631957
SecondaryResourceType preprint
Snippet Zero-field optically pumped magnetometers (OPMs) have emerged as an important technology for biomagnetism due to their ulta-sensitive performance, contained...
SourceID arxiv
SourceType Open Access Repository
SubjectTerms Physics - Atomic Physics
Title A triaxial vectorization technique for a single-beam zero-field atomic magnetometer to suppress cross-axis projection error
URI https://arxiv.org/abs/2408.12994
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwdV3LS8MwGP_YdvIiisp8fwevUZq-j0OcQ1AvCr2VtP0qA9uOdBtj_vN-SevjsksIScgT8vte-QXgxlFRmIcUCD8uWEHhVCi3JGHZsmK_yH3rPX9-CWbv3lPiJwPAn7cwSm_m644fOGvvDP_WLSNS7A1hKKUJ2Xp8TTrnpKXi6tv_tWMZ0xb9A4npAez30h1OuuM4hAHVR_A1QfM3xoZPGtfWSN6_fcRfAlVk0REVGr39k0RGqsIt6UbY-DJkvbia51ipj5o4awJYcNlgu1rYKFa0SCd4gBZ7w4rpnLRu9DFcTx_e7mfCTjdddNwSqVlJalfinsCobmoaAzpZTo4KvcCJyKPSVS7fDaWUWegHRRSHpzDe1cvZ7qpz2JOM0MZAKt0LGC31ii4ZYZfZld3mb4Smg1M
link.rule.ids 228,230,786,891
linkProvider Cornell University
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=A+triaxial+vectorization+technique+for+a+single-beam+zero-field+atomic+magnetometer+to+suppress+cross-axis+projection+error&rft.au=Dawson%2C+Rach&rft.au=Mrozowski%2C+Marcin+S&rft.au=Hunter%2C+Dominic&rft.au=O%27Dwyer%2C+Carolyn&rft.date=2024-08-23&rft_id=info:doi/10.48550%2Farxiv.2408.12994&rft.externalDocID=2408_12994