Thermal Insulation Properties of Microfibrillated Cellulose Aerogel

TS102.1; Microfibrillated cellulose ( MFC ) aerogels are bio-based materials with high thermal resistance. In this study, MFC aerogels and MFC-kapok composite aerogels were prepared. A series of experiments were carried out in a climate chamber to study the influence of MFC concentration, the temper...

Full description

Saved in:
Bibliographic Details
Published in东华大学学报(英文版) Vol. 38; no. 2; pp. 106 - 113
Main Authors YANG Simin, LUO Xinrong, AN Yuying, TU Lexi, SHEN Hua
Format Journal Article
LanguageEnglish
Published College of Textiles,Donghua University,Shanghai 201620,China%Chinatesta Textile Testing&Certification Services,Shaoxing 312071,China 30.04.2021
Subjects
Online AccessGet full text

Cover

Loading…
Abstract TS102.1; Microfibrillated cellulose ( MFC ) aerogels are bio-based materials with high thermal resistance. In this study, MFC aerogels and MFC-kapok composite aerogels were prepared. A series of experiments were carried out in a climate chamber to study the influence of MFC concentration, the temperature gradient, testing methods and introduction of kapok fibers on the thermal insulation properties of aerogels. The results suggested that the density of MFC aerogels was less than 10 mg/cm3 and the porosity was higher than 99%. Besides, the minimum thermal conductivity of MFC aerogels was 0.0357 W·m-1·K-1 observed at 0.8%MFC aerogels. The minimum thermal conductivity of MFC-kapok composite aerogels was 0.0382 W·m-1 · K-1 when the ratio of MFC to kapok was 2 :6.
AbstractList TS102.1; Microfibrillated cellulose ( MFC ) aerogels are bio-based materials with high thermal resistance. In this study, MFC aerogels and MFC-kapok composite aerogels were prepared. A series of experiments were carried out in a climate chamber to study the influence of MFC concentration, the temperature gradient, testing methods and introduction of kapok fibers on the thermal insulation properties of aerogels. The results suggested that the density of MFC aerogels was less than 10 mg/cm3 and the porosity was higher than 99%. Besides, the minimum thermal conductivity of MFC aerogels was 0.0357 W·m-1·K-1 observed at 0.8%MFC aerogels. The minimum thermal conductivity of MFC-kapok composite aerogels was 0.0382 W·m-1 · K-1 when the ratio of MFC to kapok was 2 :6.
Author YANG Simin
LUO Xinrong
SHEN Hua
AN Yuying
TU Lexi
AuthorAffiliation College of Textiles,Donghua University,Shanghai 201620,China%Chinatesta Textile Testing&Certification Services,Shaoxing 312071,China
AuthorAffiliation_xml – name: College of Textiles,Donghua University,Shanghai 201620,China%Chinatesta Textile Testing&Certification Services,Shaoxing 312071,China
Author_xml – sequence: 1
  fullname: YANG Simin
– sequence: 2
  fullname: LUO Xinrong
– sequence: 3
  fullname: AN Yuying
– sequence: 4
  fullname: TU Lexi
– sequence: 5
  fullname: SHEN Hua
BookMark eNo9j01rAyEYhD2k0DTNXyhee9iturrqMSz9CKS0h_S86PqabLBaNEvz87vQ0rkMzMA8zA1axBQBoTtKaqqV4g-nmraSVYIxUjPCCKVE8wVa_qfXaF3KicxqmeREL1G3P0L-NAFvY5mCOY8p4vecviCfRyg4efw6Djn50eYxzD043EEIU0gF8AZyOkC4RVfehALrP1-hj6fHffdS7d6et91mVxVKeFM1reXgtZjBTEirgRoirHHKUWmJ0q6hrVPgvSJOUOaY5k4Ng5XSMiusa1bo_nf320Rv4qE_pSnHmdi7o7tcbA_zaTr_Jk3zA_qoUPo
ClassificationCodes TS102.1
ContentType Journal Article
Copyright Copyright © Wanfang Data Co. Ltd. All Rights Reserved.
Copyright_xml – notice: Copyright © Wanfang Data Co. Ltd. All Rights Reserved.
DBID 2B.
4A8
92I
93N
PSX
TCJ
DOI 10.19884/j.1672-5220.202011094
DatabaseName Wanfang Data Journals - Hong Kong
WANFANG Data Centre
Wanfang Data Journals
万方数据期刊 - 香港版
China Online Journals (COJ)
China Online Journals (COJ)
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EndPage 113
ExternalDocumentID dhdxxb_e202102003
GrantInformation_xml – fundername: (National Natural Science Foundation of China); (Fundamental Research Funds for the Central Universities,China)
  funderid: (National Natural Science Foundation of China); (Fundamental Research Funds for the Central Universities,China)
GroupedDBID -02
-0B
-SB
-S~
188
2B.
4A8
5VR
5XA
5XC
8RM
92D
92I
92M
93N
9D9
9DB
ABJNI
ACGFS
ADMLS
AFUIB
ALMA_UNASSIGNED_HOLDINGS
CAJEB
CCEZO
CDRFL
CHBEP
CW9
FA0
JUIAU
PSX
Q--
R-B
RT2
S..
T8R
TCJ
TGH
TTC
U1F
U1G
U5B
U5L
UGNYK
UZ2
UZ4
ID FETCH-LOGICAL-s1043-36b4ef95740257b9e1a05bad8d17b089d316d8eff80d512d294d8ccb77b2b5bd3
ISSN 1672-5220
IngestDate Thu May 29 03:59:43 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 2
Keywords thermal resistance
freeze-drying
microfibrillated cellulose ( MFC) aerogel
thermal conductivity
kapok
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-s1043-36b4ef95740257b9e1a05bad8d17b089d316d8eff80d512d294d8ccb77b2b5bd3
PageCount 8
ParticipantIDs wanfang_journals_dhdxxb_e202102003
PublicationCentury 2000
PublicationDate 2021-04-30
PublicationDateYYYYMMDD 2021-04-30
PublicationDate_xml – month: 04
  year: 2021
  text: 2021-04-30
  day: 30
PublicationDecade 2020
PublicationTitle 东华大学学报(英文版)
PublicationTitle_FL Journal of Donghua University(English Edition)
PublicationYear 2021
Publisher College of Textiles,Donghua University,Shanghai 201620,China%Chinatesta Textile Testing&Certification Services,Shaoxing 312071,China
Publisher_xml – name: College of Textiles,Donghua University,Shanghai 201620,China%Chinatesta Textile Testing&Certification Services,Shaoxing 312071,China
SSID ssj0000627409
Score 2.1636233
Snippet TS102.1; Microfibrillated cellulose ( MFC ) aerogels are bio-based materials with high thermal resistance. In this study, MFC aerogels and MFC-kapok composite...
SourceID wanfang
SourceType Aggregation Database
StartPage 106
Title Thermal Insulation Properties of Microfibrillated Cellulose Aerogel
URI https://d.wanfangdata.com.cn/periodical/dhdxxb-e202102003
Volume 38
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lj9owELa27KU9VO22Vd-KqvqE2CaO7TjHANmuqoUeAIk9oTh2BBKCiodE--s7dkywdvew7SWxnDARnonnkW9mEPrKS8GrWIJ3wkwLs6gqO5KWZQd8CTB2KYkq2-twMOTXE_pjyqZnTy481NJ-Jy_LPw_mlfwPV2EO-GqyZP-Bsw1RmIAx8BeOwGE4PpbHsK-aYhlb14XLAP9_Gah0XUt2YOB2lUH1A7d3Npi7XO6XBqOe6c3a4VmPxinOKe4KnPZwzrDoY5GbQUZxlthBH2fcG3AsMpwxnF_hbg8LgXOBRRd3I3MphavwqwSL1F6q72miDrfZ8Ht7ZDqKNYigyc_2dLHarJ0qNUI4bN_ufy9OE-NJ-0YfFn6kgkTeRxcLGDpFQsageBZ1T-8-kJ3vCw-HApMjEyyfF4s2mCechDBju4ljwuwZjPBdcSQC561NDie8Z9a3crFOf7MFeuuDCb3EEQGb6kjP2_d5YnxyEvqKIRbeC0C8XT4KuWcwRHUy7T1dlApBa2V0JH4Jq2Lsrbqt850632quDgc508R64baC7TkB34e00HnWH9yMmtChqSxNLXipoexy380jvz34QJuTtqpgWT3zafwCPXd-T5DVQvwSnenVBXrmVcN8hXpOnIOTOAcncQ7WVXBXnINGnAMnzq_R5Cof9647rsdHZxsZ4EfMJdVVyuAPgfKQqY6KkMlCCRUlMhSpiiOuhK4qESqwTRVJqRJlKZNEEsmkit-g1mq90m9RoEvOqCxJKiWjShdSEaljJinQVTpk79AXtwQz9w5vZ_cW_f1jbvqAnp7k-yNq7TZ7_Qls05387Hj1F-L8g7c
linkProvider EBSCOhost
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Thermal+Insulation+Properties+of+Microfibrillated+Cellulose+Aerogel&rft.jtitle=%E4%B8%9C%E5%8D%8E%E5%A4%A7%E5%AD%A6%E5%AD%A6%E6%8A%A5%EF%BC%88%E8%8B%B1%E6%96%87%E7%89%88%EF%BC%89&rft.au=YANG+Simin&rft.au=LUO+Xinrong&rft.au=AN+Yuying&rft.au=TU+Lexi&rft.date=2021-04-30&rft.pub=College+of+Textiles%2CDonghua+University%2CShanghai+201620%2CChina%25Chinatesta+Textile+Testing%26Certification+Services%2CShaoxing+312071%2CChina&rft.issn=1672-5220&rft.volume=38&rft.issue=2&rft.spage=106&rft.epage=113&rft_id=info:doi/10.19884%2Fj.1672-5220.202011094&rft.externalDocID=dhdxxb_e202102003
thumbnail_s http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fwww.wanfangdata.com.cn%2Fimages%2FPeriodicalImages%2Fdhdxxb-e%2Fdhdxxb-e.jpg