Thermal Insulation Properties of Microfibrillated Cellulose Aerogel
TS102.1; Microfibrillated cellulose ( MFC ) aerogels are bio-based materials with high thermal resistance. In this study, MFC aerogels and MFC-kapok composite aerogels were prepared. A series of experiments were carried out in a climate chamber to study the influence of MFC concentration, the temper...
Saved in:
Published in | 东华大学学报(英文版) Vol. 38; no. 2; pp. 106 - 113 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
College of Textiles,Donghua University,Shanghai 201620,China%Chinatesta Textile Testing&Certification Services,Shaoxing 312071,China
30.04.2021
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | TS102.1; Microfibrillated cellulose ( MFC ) aerogels are bio-based materials with high thermal resistance. In this study, MFC aerogels and MFC-kapok composite aerogels were prepared. A series of experiments were carried out in a climate chamber to study the influence of MFC concentration, the temperature gradient, testing methods and introduction of kapok fibers on the thermal insulation properties of aerogels. The results suggested that the density of MFC aerogels was less than 10 mg/cm3 and the porosity was higher than 99%. Besides, the minimum thermal conductivity of MFC aerogels was 0.0357 W·m-1·K-1 observed at 0.8%MFC aerogels. The minimum thermal conductivity of MFC-kapok composite aerogels was 0.0382 W·m-1 · K-1 when the ratio of MFC to kapok was 2 :6. |
---|---|
AbstractList | TS102.1; Microfibrillated cellulose ( MFC ) aerogels are bio-based materials with high thermal resistance. In this study, MFC aerogels and MFC-kapok composite aerogels were prepared. A series of experiments were carried out in a climate chamber to study the influence of MFC concentration, the temperature gradient, testing methods and introduction of kapok fibers on the thermal insulation properties of aerogels. The results suggested that the density of MFC aerogels was less than 10 mg/cm3 and the porosity was higher than 99%. Besides, the minimum thermal conductivity of MFC aerogels was 0.0357 W·m-1·K-1 observed at 0.8%MFC aerogels. The minimum thermal conductivity of MFC-kapok composite aerogels was 0.0382 W·m-1 · K-1 when the ratio of MFC to kapok was 2 :6. |
Author | YANG Simin LUO Xinrong SHEN Hua AN Yuying TU Lexi |
AuthorAffiliation | College of Textiles,Donghua University,Shanghai 201620,China%Chinatesta Textile Testing&Certification Services,Shaoxing 312071,China |
AuthorAffiliation_xml | – name: College of Textiles,Donghua University,Shanghai 201620,China%Chinatesta Textile Testing&Certification Services,Shaoxing 312071,China |
Author_xml | – sequence: 1 fullname: YANG Simin – sequence: 2 fullname: LUO Xinrong – sequence: 3 fullname: AN Yuying – sequence: 4 fullname: TU Lexi – sequence: 5 fullname: SHEN Hua |
BookMark | eNo9j01rAyEYhD2k0DTNXyhee9iturrqMSz9CKS0h_S86PqabLBaNEvz87vQ0rkMzMA8zA1axBQBoTtKaqqV4g-nmraSVYIxUjPCCKVE8wVa_qfXaF3KicxqmeREL1G3P0L-NAFvY5mCOY8p4vecviCfRyg4efw6Djn50eYxzD043EEIU0gF8AZyOkC4RVfehALrP1-hj6fHffdS7d6et91mVxVKeFM1reXgtZjBTEirgRoirHHKUWmJ0q6hrVPgvSJOUOaY5k4Ng5XSMiusa1bo_nf320Rv4qE_pSnHmdi7o7tcbA_zaTr_Jk3zA_qoUPo |
ClassificationCodes | TS102.1 |
ContentType | Journal Article |
Copyright | Copyright © Wanfang Data Co. Ltd. All Rights Reserved. |
Copyright_xml | – notice: Copyright © Wanfang Data Co. Ltd. All Rights Reserved. |
DBID | 2B. 4A8 92I 93N PSX TCJ |
DOI | 10.19884/j.1672-5220.202011094 |
DatabaseName | Wanfang Data Journals - Hong Kong WANFANG Data Centre Wanfang Data Journals 万方数据期刊 - 香港版 China Online Journals (COJ) China Online Journals (COJ) |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EndPage | 113 |
ExternalDocumentID | dhdxxb_e202102003 |
GrantInformation_xml | – fundername: (National Natural Science Foundation of China); (Fundamental Research Funds for the Central Universities,China) funderid: (National Natural Science Foundation of China); (Fundamental Research Funds for the Central Universities,China) |
GroupedDBID | -02 -0B -SB -S~ 188 2B. 4A8 5VR 5XA 5XC 8RM 92D 92I 92M 93N 9D9 9DB ABJNI ACGFS ADMLS AFUIB ALMA_UNASSIGNED_HOLDINGS CAJEB CCEZO CDRFL CHBEP CW9 FA0 JUIAU PSX Q-- R-B RT2 S.. T8R TCJ TGH TTC U1F U1G U5B U5L UGNYK UZ2 UZ4 |
ID | FETCH-LOGICAL-s1043-36b4ef95740257b9e1a05bad8d17b089d316d8eff80d512d294d8ccb77b2b5bd3 |
ISSN | 1672-5220 |
IngestDate | Thu May 29 03:59:43 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 2 |
Keywords | thermal resistance freeze-drying microfibrillated cellulose ( MFC) aerogel thermal conductivity kapok |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-s1043-36b4ef95740257b9e1a05bad8d17b089d316d8eff80d512d294d8ccb77b2b5bd3 |
PageCount | 8 |
ParticipantIDs | wanfang_journals_dhdxxb_e202102003 |
PublicationCentury | 2000 |
PublicationDate | 2021-04-30 |
PublicationDateYYYYMMDD | 2021-04-30 |
PublicationDate_xml | – month: 04 year: 2021 text: 2021-04-30 day: 30 |
PublicationDecade | 2020 |
PublicationTitle | 东华大学学报(英文版) |
PublicationTitle_FL | Journal of Donghua University(English Edition) |
PublicationYear | 2021 |
Publisher | College of Textiles,Donghua University,Shanghai 201620,China%Chinatesta Textile Testing&Certification Services,Shaoxing 312071,China |
Publisher_xml | – name: College of Textiles,Donghua University,Shanghai 201620,China%Chinatesta Textile Testing&Certification Services,Shaoxing 312071,China |
SSID | ssj0000627409 |
Score | 2.1636233 |
Snippet | TS102.1; Microfibrillated cellulose ( MFC ) aerogels are bio-based materials with high thermal resistance. In this study, MFC aerogels and MFC-kapok composite... |
SourceID | wanfang |
SourceType | Aggregation Database |
StartPage | 106 |
Title | Thermal Insulation Properties of Microfibrillated Cellulose Aerogel |
URI | https://d.wanfangdata.com.cn/periodical/dhdxxb-e202102003 |
Volume | 38 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lj9owELa27KU9VO22Vd-KqvqE2CaO7TjHANmuqoUeAIk9oTh2BBKCiodE--s7dkywdvew7SWxnDARnonnkW9mEPrKS8GrWIJ3wkwLs6gqO5KWZQd8CTB2KYkq2-twMOTXE_pjyqZnTy481NJ-Jy_LPw_mlfwPV2EO-GqyZP-Bsw1RmIAx8BeOwGE4PpbHsK-aYhlb14XLAP9_Gah0XUt2YOB2lUH1A7d3Npi7XO6XBqOe6c3a4VmPxinOKe4KnPZwzrDoY5GbQUZxlthBH2fcG3AsMpwxnF_hbg8LgXOBRRd3I3MphavwqwSL1F6q72miDrfZ8Ht7ZDqKNYigyc_2dLHarJ0qNUI4bN_ufy9OE-NJ-0YfFn6kgkTeRxcLGDpFQsageBZ1T-8-kJ3vCw-HApMjEyyfF4s2mCechDBju4ljwuwZjPBdcSQC561NDie8Z9a3crFOf7MFeuuDCb3EEQGb6kjP2_d5YnxyEvqKIRbeC0C8XT4KuWcwRHUy7T1dlApBa2V0JH4Jq2Lsrbqt850632quDgc508R64baC7TkB34e00HnWH9yMmtChqSxNLXipoexy380jvz34QJuTtqpgWT3zafwCPXd-T5DVQvwSnenVBXrmVcN8hXpOnIOTOAcncQ7WVXBXnINGnAMnzq_R5Cof9647rsdHZxsZ4EfMJdVVyuAPgfKQqY6KkMlCCRUlMhSpiiOuhK4qESqwTRVJqRJlKZNEEsmkit-g1mq90m9RoEvOqCxJKiWjShdSEaljJinQVTpk79AXtwQz9w5vZ_cW_f1jbvqAnp7k-yNq7TZ7_Qls05387Hj1F-L8g7c |
linkProvider | EBSCOhost |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Thermal+Insulation+Properties+of+Microfibrillated+Cellulose+Aerogel&rft.jtitle=%E4%B8%9C%E5%8D%8E%E5%A4%A7%E5%AD%A6%E5%AD%A6%E6%8A%A5%EF%BC%88%E8%8B%B1%E6%96%87%E7%89%88%EF%BC%89&rft.au=YANG+Simin&rft.au=LUO+Xinrong&rft.au=AN+Yuying&rft.au=TU+Lexi&rft.date=2021-04-30&rft.pub=College+of+Textiles%2CDonghua+University%2CShanghai+201620%2CChina%25Chinatesta+Textile+Testing%26Certification+Services%2CShaoxing+312071%2CChina&rft.issn=1672-5220&rft.volume=38&rft.issue=2&rft.spage=106&rft.epage=113&rft_id=info:doi/10.19884%2Fj.1672-5220.202011094&rft.externalDocID=dhdxxb_e202102003 |
thumbnail_s | http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fwww.wanfangdata.com.cn%2Fimages%2FPeriodicalImages%2Fdhdxxb-e%2Fdhdxxb-e.jpg |