Evaluation of specific antibodies of blood receiver sera to Treponema pallidum by chemiluminescence immunoassay

The purpose of this study was to evaluate the diagnostic performance of chemiluminescence immunoassay (CLIA ) , in comparison with that of the following currently used treponemal tests: hemagglutination test (TPHA), and Western Blot (WB). First, a retrospective study was performed with a panel of 18...

Full description

Saved in:
Bibliographic Details
Published inZhonghua shi yan he lin chuang bing du xue za ji Vol. 27; no. 1; p. 70
Main Authors Wang, Xue-chun, Chen, Ling-zhi, Yu, Qin, Sun, Ai-hua
Format Journal Article
LanguageChinese
English
Published China 01.02.2013
Subjects
Online AccessGet more information

Cover

Loading…
Abstract The purpose of this study was to evaluate the diagnostic performance of chemiluminescence immunoassay (CLIA ) , in comparison with that of the following currently used treponemal tests: hemagglutination test (TPHA), and Western Blot (WB). First, a retrospective study was performed with a panel of 18 494 blood receiver sera by CLIA and TPHA, the specific antibody against T. pallidum in 177 were positive sera by CLIA and/or TPHA, 81 clinical and serologically characterized syphilitic sera, 55 sera obtained from subjects with potentially interfering diseases, and 250 healthy sera were negative were detected by CLIA, TPHA and WB. The results of WB as the gold standard, the sensitivity of CLIA (98. 4%) was significantly higher than that of TPHA (94. 4%) (Chi2 = 5.76,P <0. 05), the specificity of CLIA (100%) was similar to that of TPHA (99.7%) (Chi2 =1. 0, P >0. 05). CLIA is characterized with higher sensitivity and specificity, It is suitable for screening Syphilis in clinical laboratory.
AbstractList The purpose of this study was to evaluate the diagnostic performance of chemiluminescence immunoassay (CLIA ) , in comparison with that of the following currently used treponemal tests: hemagglutination test (TPHA), and Western Blot (WB). First, a retrospective study was performed with a panel of 18 494 blood receiver sera by CLIA and TPHA, the specific antibody against T. pallidum in 177 were positive sera by CLIA and/or TPHA, 81 clinical and serologically characterized syphilitic sera, 55 sera obtained from subjects with potentially interfering diseases, and 250 healthy sera were negative were detected by CLIA, TPHA and WB. The results of WB as the gold standard, the sensitivity of CLIA (98. 4%) was significantly higher than that of TPHA (94. 4%) (Chi2 = 5.76,P <0. 05), the specificity of CLIA (100%) was similar to that of TPHA (99.7%) (Chi2 =1. 0, P >0. 05). CLIA is characterized with higher sensitivity and specificity, It is suitable for screening Syphilis in clinical laboratory.
Author Chen, Ling-zhi
Yu, Qin
Sun, Ai-hua
Wang, Xue-chun
Author_xml – sequence: 1
  givenname: Xue-chun
  surname: Wang
  fullname: Wang, Xue-chun
  organization: Department of Blood Transfusion, the First Hospital of Jiaxing City in Zhejiang Province, Zhejiang 314001, China
– sequence: 2
  givenname: Ling-zhi
  surname: Chen
  fullname: Chen, Ling-zhi
– sequence: 3
  givenname: Qin
  surname: Yu
  fullname: Yu, Qin
– sequence: 4
  givenname: Ai-hua
  surname: Sun
  fullname: Sun, Ai-hua
BackLink https://www.ncbi.nlm.nih.gov/pubmed/23855137$$D View this record in MEDLINE/PubMed
BookMark eNo9j8tqwzAQRbVIadI0v1C07MbuaBTH8rKEviDQTfZhJI-piiUZKw7k75vSx-pyz-Jyz42YxRRZiHsFpa438OAClZ-lzzmWCkAXDdZNiaB0CaoExJlY_PO5WOXsLVRKbwzi-lrMUZvqUuuFSE8n6ic6-hRl6mQe2PnOO0nx6G1qPedvbPuUWjmyY3_iUWYeSR6T3I88XH4FkgP1vW-nIO1Zug8Ovp-Cj5wdR8fShzDFRDnT-VZcddRnXv3mUuyfn_bb12L3_vK2fdwVg2nqwjAY7ZSm2rTM6LByqrYNk6OKQK11DQb05qJhuxatsbhGAIPQNptKG8aluPuZHSYbuD0Mow80ng9_4vgFGgNh0g
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.3760/cma.j.issn.1003-9279.2013.01.022
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
ExternalDocumentID 23855137
Genre English Abstract
Journal Article
Comparative Study
GroupedDBID ---
-05
2B.
92F
92I
ABJNI
ACGFS
ALMA_UNASSIGNED_HOLDINGS
CCEZO
CGR
CIEJG
CUY
CVF
CW9
ECM
EIF
F5P
NPM
TCJ
TGQ
U1G
U5O
ID FETCH-LOGICAL-p897-8e083c13a78dee2c25c17b9eaca5a0143708036238bfd2b8b24200820d96538e2
ISSN 1003-9279
IngestDate Wed Feb 19 01:52:07 EST 2025
IsPeerReviewed false
IsScholarly true
Issue 1
Language Chinese
English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-p897-8e083c13a78dee2c25c17b9eaca5a0143708036238bfd2b8b24200820d96538e2
PMID 23855137
ParticipantIDs pubmed_primary_23855137
PublicationCentury 2000
PublicationDate 2013-Feb
PublicationDateYYYYMMDD 2013-02-01
PublicationDate_xml – month: 02
  year: 2013
  text: 2013-Feb
PublicationDecade 2010
PublicationPlace China
PublicationPlace_xml – name: China
PublicationTitle Zhonghua shi yan he lin chuang bing du xue za ji
PublicationTitleAlternate Zhonghua Shi Yan He Lin Chuang Bing Du Xue Za Zhi
PublicationYear 2013
SSID ssib051368224
ssib036442120
ssj0041992
ssib001103481
Score 1.8508075
Snippet The purpose of this study was to evaluate the diagnostic performance of chemiluminescence immunoassay (CLIA ) , in comparison with that of the following...
SourceID pubmed
SourceType Index Database
StartPage 70
SubjectTerms Antibodies, Bacterial - blood
Antibodies, Bacterial - immunology
Blotting, Western - methods
Case-Control Studies
Hemagglutination Tests - methods
Humans
Immunoassay - methods
Luminescence
Luminescent Measurements - methods
Retrospective Studies
Sensitivity and Specificity
Syphilis - blood
Syphilis - microbiology
Treponema pallidum - immunology
Title Evaluation of specific antibodies of blood receiver sera to Treponema pallidum by chemiluminescence immunoassay
URI https://www.ncbi.nlm.nih.gov/pubmed/23855137
Volume 27
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1da9swFBVpB2Mvo2PfXYce9jAQzhbbie3HUVrKYIOxDLK9FEmWY5cmDiyGNr9qP3HnSrbiZhvd9mKMbCu278n1kXTuvYy9yqM0Hes8D0Bd3waxKuIApN5gL03UBPwksyu6Hz5Ozr7E72fj2WDwo6daatZqqDe_jSv5H6uiDXalKNl_sKzvFA3Yh32xhYWx_Ssbn_hU3cT5KGiShD8CL6tSNckDqdlK0wUcmyEJhqCyD0Q4p7RasDQLKVby8rLKmwUxUU35A-CvSAyv7Z--ogCSGhRb3lgA_lbWy3nZSPG9rMQ1nATgZjXtaFvOhaIZiLwRV40RGykuqu3EvXMus8YEONdD87iNEsHYeB5sSn_-14ZaP1X-xM-NS3pQBfil_pwF1Y_w-g_nZkkRl4WujEznh12OgBt4c07VVRbZ9fWk5oGB9EIOL2yvQ98rKfYil4017F8K660WFgsgKlTZJrn96E427u7QHtvDuIQKrfZmh0Cl-nHNEbgmmIH3h7huQqLdjinEJP21q_Htfd9lr9sHe3PbY1ES6_ZWdgZElhhND9j9dkTD3zl4PmCDTfmQ1Vto8rrgHTT5FprUbKHJO2hygiZf19xDk3fQ5Oqa_wJN3oPmIzY9PZkenwVtbY9glWbgRQbUX48imaS5MaEOx3qUqAwsQI4lpZxMMJIBt4pSVeShShWYpGWreTbBJ9qEj9n-EnfylPEkUTrRcW7jaVQ2SqXJilCbUYFOMYB4xp6413O-cvlbzrsX9_yPRw7ZvS1sX7A7BRyGOQL7XKuX1uQ_AfuFfpA
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+specific+antibodies+of+blood+receiver+sera+to+Treponema+pallidum+by+chemiluminescence+immunoassay&rft.jtitle=Zhonghua+shi+yan+he+lin+chuang+bing+du+xue+za+ji&rft.au=Wang%2C+Xue-chun&rft.au=Chen%2C+Ling-zhi&rft.au=Yu%2C+Qin&rft.au=Sun%2C+Ai-hua&rft.date=2013-02-01&rft.issn=1003-9279&rft.volume=27&rft.issue=1&rft.spage=70&rft_id=info:doi/10.3760%2Fcma.j.issn.1003-9279.2013.01.022&rft_id=info%3Apmid%2F23855137&rft_id=info%3Apmid%2F23855137&rft.externalDocID=23855137
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1003-9279&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1003-9279&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1003-9279&client=summon