PET-MR Attenuation Correction using 3D Multi-Echo Dixon-Based UTE Sequence
Objectives: Accurate estimation of PET attenuation coefficients (AC) is a challenging problem in PET/MR1. Current MR-based AC method widely used in the PET/MR scanners segments an MR image into different tissue classes (e.g., air, lung, fat, and soft-tissue) and then assigns a single AC value for ea...
Saved in:
Published in | The Journal of nuclear medicine (1978) Vol. 59; p. 652 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
New York
Society of Nuclear Medicine
01.05.2018
|
Subjects | |
Online Access | Get full text |
ISSN | 0161-5505 1535-5667 |
Cover
Abstract | Objectives: Accurate estimation of PET attenuation coefficients (AC) is a challenging problem in PET/MR1. Current MR-based AC method widely used in the PET/MR scanners segments an MR image into different tissue classes (e.g., air, lung, fat, and soft-tissue) and then assigns a single AC value for each class. This method does not account for intra- and/or inter-subject variations2-5, and can lead to unacceptable biases especially in areas such as bone6. Thus, accurate representation of bone AC with a continuous variation is necessary for reliable PET/MR imaging7-8. In this work, we propose a new MR acquisition method that integrates UTE and multi-echo Dixon in a single acquisition and a new quantification method to represent continuous variation of water, fat and bone AC using MR. The performance of the proposed method is evaluated via a phantom study. Methods A phantom was made by placing a pig tibia containing muscle, fat, and bone inside a plastic container. The container was then filled with 5% gelatin containing radioactive 18F to resemble background soft-tissue. The phantom was first imaged using a whole-body PET-MR scanner (mMR, Siemens Healthcare, Erlangen, Germany). The PET list-mode acquisition was performed for 10 min. MR acquisition was performed using the proposed 3D UTE/multi-echo Dixon sequence (Fig.1A) with the following imaging parameters: resolution = 1.875×1.875×1.875 mm3, TE = 70, 2110, 2810, 3550, 4250, 4990, 5690 μs, and acquisition time = ~1 min. UTE/multi-echo Dixon images were reconstructed using non-uniform fast Fourier transform (NUFFT)9 and SENSE10 reconstruction. The phantom was then imaged using a CT scanner (Biograph 64, Siemens Healthcare, Erlangen, Germany) with tube peak voltage = 120 kVp and tube current time product 30 = mAs. The CT images were reconstructed with in-plane resolution = 0.56×0.56 mm2 and slice-thickness = 1 mm. Water, fat, and bone signals were estimated using the signal model shown in Fig.1B. I(TEp) denote the image from the pth echo time with p = 1,⋯, 7, ρB, ρW, and ρF each denote the proton density signals of bone, water and fat, respectively, R2[asterisk] denote the single representative relaxation rate of both water and fat, Δffat denote the chemical shift of main-peak fat with respect to water, Δfoffset denote frequency offset to account for different fat components, and ΔfB0 denotes the frequency offset due to magnetic field inhomogeneity (B0). The pseudo-CT map was generated using the model shown in Fig.1C. μmapsoftdenotes the AC map of soft tissue only, FF denotes fat fraction, LACwater denotes the linear AC (LAC) of water (0.100 cm-1 at 511 keV5), LACfat denotes the LAC of fat (0.086 cm-1 at 511 keV5), μmapbonedenotes the AC map containing bone, BF denotes bone fraction, and LACbone denotes the linear AC (LAC) of bone (0.172 cm-1 at 511 keV5). The AC maps obtained by the proposed method were compared with those obtained by the two-point Dixon method implemented by the manufacturer and those from the CT scan as the ground truth using Pearson’s linear correlation. Results Noticeable swap of fat and water signals were observed from the water and fat images obtained from the scanner’s method (Fig.1D). Water, fat and bone maps were successfully obtained using the proposed method (Fig.1D). Continuous bone AC was successfully obtained using the proposed method over the bone region (Fig.1E). The pseudo-CT map generated from the proposed method showed visually similar representation over fat (yellow arrowhead) and bone regions (red arrows), showing higher correlation (r=0.90) with the CT map compared to the pseudo-CT map generated from the scanner’s method (r=0.85). Conclusion The proposed method can be used to obtain continuous water, fat and bone AC using MR and potentially can be used to generate subject-specific AC maps in PET/MR applications. |
---|---|
AbstractList | Objectives: Accurate estimation of PET attenuation coefficients (AC) is a challenging problem in PET/MR1. Current MR-based AC method widely used in the PET/MR scanners segments an MR image into different tissue classes (e.g., air, lung, fat, and soft-tissue) and then assigns a single AC value for each class. This method does not account for intra- and/or inter-subject variations2-5, and can lead to unacceptable biases especially in areas such as bone6. Thus, accurate representation of bone AC with a continuous variation is necessary for reliable PET/MR imaging7-8. In this work, we propose a new MR acquisition method that integrates UTE and multi-echo Dixon in a single acquisition and a new quantification method to represent continuous variation of water, fat and bone AC using MR. The performance of the proposed method is evaluated via a phantom study. Methods A phantom was made by placing a pig tibia containing muscle, fat, and bone inside a plastic container. The container was then filled with 5% gelatin containing radioactive 18F to resemble background soft-tissue. The phantom was first imaged using a whole-body PET-MR scanner (mMR, Siemens Healthcare, Erlangen, Germany). The PET list-mode acquisition was performed for 10 min. MR acquisition was performed using the proposed 3D UTE/multi-echo Dixon sequence (Fig.1A) with the following imaging parameters: resolution = 1.875×1.875×1.875 mm3, TE = 70, 2110, 2810, 3550, 4250, 4990, 5690 μs, and acquisition time = ~1 min. UTE/multi-echo Dixon images were reconstructed using non-uniform fast Fourier transform (NUFFT)9 and SENSE10 reconstruction. The phantom was then imaged using a CT scanner (Biograph 64, Siemens Healthcare, Erlangen, Germany) with tube peak voltage = 120 kVp and tube current time product 30 = mAs. The CT images were reconstructed with in-plane resolution = 0.56×0.56 mm2 and slice-thickness = 1 mm. Water, fat, and bone signals were estimated using the signal model shown in Fig.1B. I(TEp) denote the image from the pth echo time with p = 1,⋯, 7, ρB, ρW, and ρF each denote the proton density signals of bone, water and fat, respectively, R2[asterisk] denote the single representative relaxation rate of both water and fat, Δffat denote the chemical shift of main-peak fat with respect to water, Δfoffset denote frequency offset to account for different fat components, and ΔfB0 denotes the frequency offset due to magnetic field inhomogeneity (B0). The pseudo-CT map was generated using the model shown in Fig.1C. μmapsoft denotes the AC map of soft tissue only, FF denotes fat fraction, LACwater denotes the linear AC (LAC) of water (0.100 cm-1 at 511 keV5), LACfat denotes the LAC of fat (0.086 cm-1 at 511 keV5), μmapbone denotes the AC map containing bone, BF denotes bone fraction, and LACbone denotes the linear AC (LAC) of bone (0.172 cm-1 at 511 keV5). The AC maps obtained by the proposed method were compared with those obtained by the two-point Dixon method implemented by the manufacturer and those from the CT scan as the ground truth using Pearson's linear correlation. Results Noticeable swap of fat and water signals were observed from the water and fat images obtained from the scanner's method (Fig.1D). Water, fat and bone maps were successfully obtained using the proposed method (Fig.1D). Continuous bone AC was successfully obtained using the proposed method over the bone region (Fig.1E). The pseudo-CT map generated from the proposed method showed visually similar representation over fat (yellow arrowhead) and bone regions (red arrows), showing higher correlation (r=0.90) with the CT map compared to the pseudo-CT map generated from the scanner's method (r=0.85). Conclusion The proposed method can be used to obtain continuous water, fat and bone AC using MR and potentially can be used to generate subject-specific AC maps in PET/MR applications. Objectives: Accurate estimation of PET attenuation coefficients (AC) is a challenging problem in PET/MR1. Current MR-based AC method widely used in the PET/MR scanners segments an MR image into different tissue classes (e.g., air, lung, fat, and soft-tissue) and then assigns a single AC value for each class. This method does not account for intra- and/or inter-subject variations2-5, and can lead to unacceptable biases especially in areas such as bone6. Thus, accurate representation of bone AC with a continuous variation is necessary for reliable PET/MR imaging7-8. In this work, we propose a new MR acquisition method that integrates UTE and multi-echo Dixon in a single acquisition and a new quantification method to represent continuous variation of water, fat and bone AC using MR. The performance of the proposed method is evaluated via a phantom study. Methods A phantom was made by placing a pig tibia containing muscle, fat, and bone inside a plastic container. The container was then filled with 5% gelatin containing radioactive 18F to resemble background soft-tissue. The phantom was first imaged using a whole-body PET-MR scanner (mMR, Siemens Healthcare, Erlangen, Germany). The PET list-mode acquisition was performed for 10 min. MR acquisition was performed using the proposed 3D UTE/multi-echo Dixon sequence (Fig.1A) with the following imaging parameters: resolution = 1.875×1.875×1.875 mm3, TE = 70, 2110, 2810, 3550, 4250, 4990, 5690 μs, and acquisition time = ~1 min. UTE/multi-echo Dixon images were reconstructed using non-uniform fast Fourier transform (NUFFT)9 and SENSE10 reconstruction. The phantom was then imaged using a CT scanner (Biograph 64, Siemens Healthcare, Erlangen, Germany) with tube peak voltage = 120 kVp and tube current time product 30 = mAs. The CT images were reconstructed with in-plane resolution = 0.56×0.56 mm2 and slice-thickness = 1 mm. Water, fat, and bone signals were estimated using the signal model shown in Fig.1B. I(TEp) denote the image from the pth echo time with p = 1,⋯, 7, ρB, ρW, and ρF each denote the proton density signals of bone, water and fat, respectively, R2[asterisk] denote the single representative relaxation rate of both water and fat, Δffat denote the chemical shift of main-peak fat with respect to water, Δfoffset denote frequency offset to account for different fat components, and ΔfB0 denotes the frequency offset due to magnetic field inhomogeneity (B0). The pseudo-CT map was generated using the model shown in Fig.1C. μmapsoftdenotes the AC map of soft tissue only, FF denotes fat fraction, LACwater denotes the linear AC (LAC) of water (0.100 cm-1 at 511 keV5), LACfat denotes the LAC of fat (0.086 cm-1 at 511 keV5), μmapbonedenotes the AC map containing bone, BF denotes bone fraction, and LACbone denotes the linear AC (LAC) of bone (0.172 cm-1 at 511 keV5). The AC maps obtained by the proposed method were compared with those obtained by the two-point Dixon method implemented by the manufacturer and those from the CT scan as the ground truth using Pearson’s linear correlation. Results Noticeable swap of fat and water signals were observed from the water and fat images obtained from the scanner’s method (Fig.1D). Water, fat and bone maps were successfully obtained using the proposed method (Fig.1D). Continuous bone AC was successfully obtained using the proposed method over the bone region (Fig.1E). The pseudo-CT map generated from the proposed method showed visually similar representation over fat (yellow arrowhead) and bone regions (red arrows), showing higher correlation (r=0.90) with the CT map compared to the pseudo-CT map generated from the scanner’s method (r=0.85). Conclusion The proposed method can be used to obtain continuous water, fat and bone AC using MR and potentially can be used to generate subject-specific AC maps in PET/MR applications. |
Author | Horng, Debra Ouyang, Jinsong Lai, Xiaochun Ma, Chao Fakhri, Georges El Han, Paul |
Author_xml | – sequence: 1 givenname: Paul surname: Han fullname: Han, Paul – sequence: 2 givenname: Debra surname: Horng fullname: Horng, Debra – sequence: 3 givenname: Xiaochun surname: Lai fullname: Lai, Xiaochun – sequence: 4 givenname: Georges surname: Fakhri middlename: El fullname: Fakhri, Georges El – sequence: 5 givenname: Jinsong surname: Ouyang fullname: Ouyang, Jinsong – sequence: 6 givenname: Chao surname: Ma fullname: Ma, Chao |
BookMark | eNp9jcFKAzEURYNUcFr9h4DrQDJ5L02WtR210qLouC7PTEanlKROZsDPt6hrV-cuDvdM2SSmGM5YoVCjQGPmE1ZIZZRAlHjBpjnvpZTGWluwh6eqFttnvhiGEEcauhT5MvV98D9zzF1853rFt-Nh6ETlPxJfdV8pihvKoeGvdcVfwucYog-X7LylQw5Xf5yx-raql_di83i3Xi424ogGBaFpygDag7RAVpXWamqobBUpA6S1c2iC9QFp3jYO3qwEJED0AA20rZ6x69_bY59O4Tzs9mns46m4K0EjgnEl_msprdA5a6X-Bh1BVPw |
ContentType | Journal Article |
Copyright | Copyright Society of Nuclear Medicine May 1, 2018 |
Copyright_xml | – notice: Copyright Society of Nuclear Medicine May 1, 2018 |
DBID | 4T- 8FD FR3 K9. M7Z NAPCQ P64 |
DatabaseName | Docstoc Technology Research Database Engineering Research Database ProQuest Health & Medical Complete (Alumni) Biochemistry Abstracts 1 Nursing & Allied Health Premium Biotechnology and BioEngineering Abstracts |
DatabaseTitle | Nursing & Allied Health Premium Technology Research Database Docstoc Biochemistry Abstracts 1 ProQuest Health & Medical Complete (Alumni) Engineering Research Database Biotechnology and BioEngineering Abstracts |
DatabaseTitleList | Nursing & Allied Health Premium Nursing & Allied Health Premium |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1535-5667 |
GeographicLocations | Germany |
GeographicLocations_xml | – name: Germany |
GroupedDBID | --- -~X .55 29L 2WC 4T- 53G 5RE 8FD 8R4 8R5 8WZ A6W ABSQV ACGOD ACIWK ACPRK ADDZX ADMOG AENEX AFOSN AFRAH AHMBA ALIPV ALMA_UNASSIGNED_HOLDINGS CS3 DIK DU5 E3Z EBD EBS EJD EMOBN F5P F9R FR3 H13 I-F INIJC K9. KQ8 L7B M7Z NAPCQ OK1 P2P P64 Q2X R0Z RHI RNS RWL SJN SV3 TAE TR2 TSM TUS W8F WH7 WOQ X7M YHG |
ID | FETCH-LOGICAL-p565-a56d2e43c4084a812883ada2f1a164a339956e8ce5a7fd94b8045a455c44d4ff3 |
ISSN | 0161-5505 |
IngestDate | Mon Jun 30 10:45:31 EDT 2025 Mon Jun 30 10:37:55 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-p565-a56d2e43c4084a812883ada2f1a164a339956e8ce5a7fd94b8045a455c44d4ff3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 |
PQID | 2131599880 |
PQPubID | 40808 |
ParticipantIDs | proquest_journals_2435546925 proquest_journals_2131599880 |
PublicationCentury | 2000 |
PublicationDate | 20180501 |
PublicationDateYYYYMMDD | 2018-05-01 |
PublicationDate_xml | – month: 05 year: 2018 text: 20180501 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | New York |
PublicationPlace_xml | – name: New York |
PublicationTitle | The Journal of nuclear medicine (1978) |
PublicationYear | 2018 |
Publisher | Society of Nuclear Medicine |
Publisher_xml | – name: Society of Nuclear Medicine |
SSID | ssj0006888 |
Score | 2.2467687 |
Snippet | Objectives: Accurate estimation of PET attenuation coefficients (AC) is a challenging problem in PET/MR1. Current MR-based AC method widely used in the PET/MR... |
SourceID | proquest |
SourceType | Aggregation Database |
StartPage | 652 |
SubjectTerms | 3-D technology Accuracy Attenuation coefficients Background radiation Bone density Chemical equilibrium Computed tomography Containers Error correction & detection Fast Fourier transformations Fourier transforms Gelatin Ground truth Health care Image acquisition Image reconstruction Inhomogeneity Medical imaging Muscles Organic chemistry Positron emission Positron emission tomography Proton density (concentration) Representations Scanners Soft tissues Tibia Tissue engineering Tomography |
Title | PET-MR Attenuation Correction using 3D Multi-Echo Dixon-Based UTE Sequence |
URI | https://www.proquest.com/docview/2131599880 https://www.proquest.com/docview/2435546925 |
Volume | 59 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bS8MwGA1uD-KLeMXLlDz4NiJNm7Td43Qd9bIhWmFvI00yJsomcwPx1_s16dqKQ9SXUFrahp7k5OTrd0HozJFCeNRVhIkQmgCmYpqVDNOuAj0cBm5q6qf0-n78yK4HfFBW2zTRJfP0XH6sjCv5D6pwDnDNomT_gGzxUDgBx4AvtIAwtL_C-C5KSO--2Z6D8LUpu2F-zwyHweHCmAG8TtME2ZIIiA4Y7n06IRewdKnmYxIBVVhP6qpGLaPFXqybh8xKSxR_4U1qJ9gVVmwIsbWiVr0M4-nMskgn-zNduP3Y4teDJzGV40UxLrvieWwj3q2J_q0ZvVTNETQsnf-sOTL3NTXmDtu9XtVJILdi-pRkWyO7CC2ZlxPQlkGVmvNk4ZZbfZvq9mvO7Lj9MLzrdIe3V_2bGqp51Gyrr26K1dgPTe3R4pXf1lwjJJIttJl_Wdy2cG6jNT3ZQevL7u-ia4sqrqCKS1SxQRV7HVyiiiuoYkAVL1HdQ0k3Si5jkle8IK8grIngvnI18yRzQpg7NKsELZRwR1TArlZ4JgxZh1JzEYxUi6UhCHLBOJeMKTYaefuoPplO9AHCLaaV5CBOqdDMkYGgoRYgPrnDfN9R9BA1lp9hmI_ot6FLPVC3LaD01ZdZJk79lsuPfr77GG2UQ6OB6vPZQp-AdpunpwacTwevRYc |
linkProvider | Flying Publisher |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=PET-MR+Attenuation+Correction+using+3D+Multi-Echo+Dixon-Based+UTE+Sequence&rft.jtitle=The+Journal+of+nuclear+medicine+%281978%29&rft.au=Han%2C+Paul&rft.au=Horng%2C+Debra&rft.au=Lai%2C+Xiaochun&rft.au=Fakhri%2C+Georges+El&rft.date=2018-05-01&rft.pub=Society+of+Nuclear+Medicine&rft.issn=0161-5505&rft.eissn=1535-5667&rft.volume=59&rft.spage=652&rft.externalDBID=HAS_PDF_LINK |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0161-5505&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0161-5505&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0161-5505&client=summon |