PET-MR Attenuation Correction using 3D Multi-Echo Dixon-Based UTE Sequence

Objectives: Accurate estimation of PET attenuation coefficients (AC) is a challenging problem in PET/MR1. Current MR-based AC method widely used in the PET/MR scanners segments an MR image into different tissue classes (e.g., air, lung, fat, and soft-tissue) and then assigns a single AC value for ea...

Full description

Saved in:
Bibliographic Details
Published inThe Journal of nuclear medicine (1978) Vol. 59; p. 652
Main Authors Han, Paul, Horng, Debra, Lai, Xiaochun, Fakhri, Georges El, Ouyang, Jinsong, Ma, Chao
Format Journal Article
LanguageEnglish
Published New York Society of Nuclear Medicine 01.05.2018
Subjects
Online AccessGet full text
ISSN0161-5505
1535-5667

Cover

Abstract Objectives: Accurate estimation of PET attenuation coefficients (AC) is a challenging problem in PET/MR1. Current MR-based AC method widely used in the PET/MR scanners segments an MR image into different tissue classes (e.g., air, lung, fat, and soft-tissue) and then assigns a single AC value for each class. This method does not account for intra- and/or inter-subject variations2-5, and can lead to unacceptable biases especially in areas such as bone6. Thus, accurate representation of bone AC with a continuous variation is necessary for reliable PET/MR imaging7-8. In this work, we propose a new MR acquisition method that integrates UTE and multi-echo Dixon in a single acquisition and a new quantification method to represent continuous variation of water, fat and bone AC using MR. The performance of the proposed method is evaluated via a phantom study. Methods A phantom was made by placing a pig tibia containing muscle, fat, and bone inside a plastic container. The container was then filled with 5% gelatin containing radioactive 18F to resemble background soft-tissue. The phantom was first imaged using a whole-body PET-MR scanner (mMR, Siemens Healthcare, Erlangen, Germany). The PET list-mode acquisition was performed for 10 min. MR acquisition was performed using the proposed 3D UTE/multi-echo Dixon sequence (Fig.1A) with the following imaging parameters: resolution = 1.875×1.875×1.875 mm3, TE = 70, 2110, 2810, 3550, 4250, 4990, 5690 μs, and acquisition time = ~1 min. UTE/multi-echo Dixon images were reconstructed using non-uniform fast Fourier transform (NUFFT)9 and SENSE10 reconstruction. The phantom was then imaged using a CT scanner (Biograph 64, Siemens Healthcare, Erlangen, Germany) with tube peak voltage = 120 kVp and tube current time product 30 = mAs. The CT images were reconstructed with in-plane resolution = 0.56×0.56 mm2 and slice-thickness = 1 mm. Water, fat, and bone signals were estimated using the signal model shown in Fig.1B. I(TEp) denote the image from the pth echo time with p = 1,⋯, 7, ρB, ρW, and ρF each denote the proton density signals of bone, water and fat, respectively, R2[asterisk] denote the single representative relaxation rate of both water and fat, Δffat denote the chemical shift of main-peak fat with respect to water, Δfoffset denote frequency offset to account for different fat components, and ΔfB0 denotes the frequency offset due to magnetic field inhomogeneity (B0). The pseudo-CT map was generated using the model shown in Fig.1C. μmapsoftdenotes the AC map of soft tissue only, FF denotes fat fraction, LACwater denotes the linear AC (LAC) of water (0.100 cm-1 at 511 keV5), LACfat denotes the LAC of fat (0.086 cm-1 at 511 keV5), μmapbonedenotes the AC map containing bone, BF denotes bone fraction, and LACbone denotes the linear AC (LAC) of bone (0.172 cm-1 at 511 keV5). The AC maps obtained by the proposed method were compared with those obtained by the two-point Dixon method implemented by the manufacturer and those from the CT scan as the ground truth using Pearson’s linear correlation. Results Noticeable swap of fat and water signals were observed from the water and fat images obtained from the scanner’s method (Fig.1D). Water, fat and bone maps were successfully obtained using the proposed method (Fig.1D). Continuous bone AC was successfully obtained using the proposed method over the bone region (Fig.1E). The pseudo-CT map generated from the proposed method showed visually similar representation over fat (yellow arrowhead) and bone regions (red arrows), showing higher correlation (r=0.90) with the CT map compared to the pseudo-CT map generated from the scanner’s method (r=0.85). Conclusion The proposed method can be used to obtain continuous water, fat and bone AC using MR and potentially can be used to generate subject-specific AC maps in PET/MR applications.
AbstractList Objectives: Accurate estimation of PET attenuation coefficients (AC) is a challenging problem in PET/MR1. Current MR-based AC method widely used in the PET/MR scanners segments an MR image into different tissue classes (e.g., air, lung, fat, and soft-tissue) and then assigns a single AC value for each class. This method does not account for intra- and/or inter-subject variations2-5, and can lead to unacceptable biases especially in areas such as bone6. Thus, accurate representation of bone AC with a continuous variation is necessary for reliable PET/MR imaging7-8. In this work, we propose a new MR acquisition method that integrates UTE and multi-echo Dixon in a single acquisition and a new quantification method to represent continuous variation of water, fat and bone AC using MR. The performance of the proposed method is evaluated via a phantom study. Methods A phantom was made by placing a pig tibia containing muscle, fat, and bone inside a plastic container. The container was then filled with 5% gelatin containing radioactive 18F to resemble background soft-tissue. The phantom was first imaged using a whole-body PET-MR scanner (mMR, Siemens Healthcare, Erlangen, Germany). The PET list-mode acquisition was performed for 10 min. MR acquisition was performed using the proposed 3D UTE/multi-echo Dixon sequence (Fig.1A) with the following imaging parameters: resolution = 1.875×1.875×1.875 mm3, TE = 70, 2110, 2810, 3550, 4250, 4990, 5690 μs, and acquisition time = ~1 min. UTE/multi-echo Dixon images were reconstructed using non-uniform fast Fourier transform (NUFFT)9 and SENSE10 reconstruction. The phantom was then imaged using a CT scanner (Biograph 64, Siemens Healthcare, Erlangen, Germany) with tube peak voltage = 120 kVp and tube current time product 30 = mAs. The CT images were reconstructed with in-plane resolution = 0.56×0.56 mm2 and slice-thickness = 1 mm. Water, fat, and bone signals were estimated using the signal model shown in Fig.1B. I(TEp) denote the image from the pth echo time with p = 1,⋯, 7, ρB, ρW, and ρF each denote the proton density signals of bone, water and fat, respectively, R2[asterisk] denote the single representative relaxation rate of both water and fat, Δffat denote the chemical shift of main-peak fat with respect to water, Δfoffset denote frequency offset to account for different fat components, and ΔfB0 denotes the frequency offset due to magnetic field inhomogeneity (B0). The pseudo-CT map was generated using the model shown in Fig.1C. μmapsoft denotes the AC map of soft tissue only, FF denotes fat fraction, LACwater denotes the linear AC (LAC) of water (0.100 cm-1 at 511 keV5), LACfat denotes the LAC of fat (0.086 cm-1 at 511 keV5), μmapbone denotes the AC map containing bone, BF denotes bone fraction, and LACbone denotes the linear AC (LAC) of bone (0.172 cm-1 at 511 keV5). The AC maps obtained by the proposed method were compared with those obtained by the two-point Dixon method implemented by the manufacturer and those from the CT scan as the ground truth using Pearson's linear correlation. Results Noticeable swap of fat and water signals were observed from the water and fat images obtained from the scanner's method (Fig.1D). Water, fat and bone maps were successfully obtained using the proposed method (Fig.1D). Continuous bone AC was successfully obtained using the proposed method over the bone region (Fig.1E). The pseudo-CT map generated from the proposed method showed visually similar representation over fat (yellow arrowhead) and bone regions (red arrows), showing higher correlation (r=0.90) with the CT map compared to the pseudo-CT map generated from the scanner's method (r=0.85). Conclusion The proposed method can be used to obtain continuous water, fat and bone AC using MR and potentially can be used to generate subject-specific AC maps in PET/MR applications.
Objectives: Accurate estimation of PET attenuation coefficients (AC) is a challenging problem in PET/MR1. Current MR-based AC method widely used in the PET/MR scanners segments an MR image into different tissue classes (e.g., air, lung, fat, and soft-tissue) and then assigns a single AC value for each class. This method does not account for intra- and/or inter-subject variations2-5, and can lead to unacceptable biases especially in areas such as bone6. Thus, accurate representation of bone AC with a continuous variation is necessary for reliable PET/MR imaging7-8. In this work, we propose a new MR acquisition method that integrates UTE and multi-echo Dixon in a single acquisition and a new quantification method to represent continuous variation of water, fat and bone AC using MR. The performance of the proposed method is evaluated via a phantom study. Methods A phantom was made by placing a pig tibia containing muscle, fat, and bone inside a plastic container. The container was then filled with 5% gelatin containing radioactive 18F to resemble background soft-tissue. The phantom was first imaged using a whole-body PET-MR scanner (mMR, Siemens Healthcare, Erlangen, Germany). The PET list-mode acquisition was performed for 10 min. MR acquisition was performed using the proposed 3D UTE/multi-echo Dixon sequence (Fig.1A) with the following imaging parameters: resolution = 1.875×1.875×1.875 mm3, TE = 70, 2110, 2810, 3550, 4250, 4990, 5690 μs, and acquisition time = ~1 min. UTE/multi-echo Dixon images were reconstructed using non-uniform fast Fourier transform (NUFFT)9 and SENSE10 reconstruction. The phantom was then imaged using a CT scanner (Biograph 64, Siemens Healthcare, Erlangen, Germany) with tube peak voltage = 120 kVp and tube current time product 30 = mAs. The CT images were reconstructed with in-plane resolution = 0.56×0.56 mm2 and slice-thickness = 1 mm. Water, fat, and bone signals were estimated using the signal model shown in Fig.1B. I(TEp) denote the image from the pth echo time with p = 1,⋯, 7, ρB, ρW, and ρF each denote the proton density signals of bone, water and fat, respectively, R2[asterisk] denote the single representative relaxation rate of both water and fat, Δffat denote the chemical shift of main-peak fat with respect to water, Δfoffset denote frequency offset to account for different fat components, and ΔfB0 denotes the frequency offset due to magnetic field inhomogeneity (B0). The pseudo-CT map was generated using the model shown in Fig.1C. μmapsoftdenotes the AC map of soft tissue only, FF denotes fat fraction, LACwater denotes the linear AC (LAC) of water (0.100 cm-1 at 511 keV5), LACfat denotes the LAC of fat (0.086 cm-1 at 511 keV5), μmapbonedenotes the AC map containing bone, BF denotes bone fraction, and LACbone denotes the linear AC (LAC) of bone (0.172 cm-1 at 511 keV5). The AC maps obtained by the proposed method were compared with those obtained by the two-point Dixon method implemented by the manufacturer and those from the CT scan as the ground truth using Pearson’s linear correlation. Results Noticeable swap of fat and water signals were observed from the water and fat images obtained from the scanner’s method (Fig.1D). Water, fat and bone maps were successfully obtained using the proposed method (Fig.1D). Continuous bone AC was successfully obtained using the proposed method over the bone region (Fig.1E). The pseudo-CT map generated from the proposed method showed visually similar representation over fat (yellow arrowhead) and bone regions (red arrows), showing higher correlation (r=0.90) with the CT map compared to the pseudo-CT map generated from the scanner’s method (r=0.85). Conclusion The proposed method can be used to obtain continuous water, fat and bone AC using MR and potentially can be used to generate subject-specific AC maps in PET/MR applications.
Author Horng, Debra
Ouyang, Jinsong
Lai, Xiaochun
Ma, Chao
Fakhri, Georges El
Han, Paul
Author_xml – sequence: 1
  givenname: Paul
  surname: Han
  fullname: Han, Paul
– sequence: 2
  givenname: Debra
  surname: Horng
  fullname: Horng, Debra
– sequence: 3
  givenname: Xiaochun
  surname: Lai
  fullname: Lai, Xiaochun
– sequence: 4
  givenname: Georges
  surname: Fakhri
  middlename: El
  fullname: Fakhri, Georges El
– sequence: 5
  givenname: Jinsong
  surname: Ouyang
  fullname: Ouyang, Jinsong
– sequence: 6
  givenname: Chao
  surname: Ma
  fullname: Ma, Chao
BookMark eNp9jcFKAzEURYNUcFr9h4DrQDJ5L02WtR210qLouC7PTEanlKROZsDPt6hrV-cuDvdM2SSmGM5YoVCjQGPmE1ZIZZRAlHjBpjnvpZTGWluwh6eqFttnvhiGEEcauhT5MvV98D9zzF1853rFt-Nh6ETlPxJfdV8pihvKoeGvdcVfwucYog-X7LylQw5Xf5yx-raql_di83i3Xi424ogGBaFpygDag7RAVpXWamqobBUpA6S1c2iC9QFp3jYO3qwEJED0AA20rZ6x69_bY59O4Tzs9mns46m4K0EjgnEl_msprdA5a6X-Bh1BVPw
ContentType Journal Article
Copyright Copyright Society of Nuclear Medicine May 1, 2018
Copyright_xml – notice: Copyright Society of Nuclear Medicine May 1, 2018
DBID 4T-
8FD
FR3
K9.
M7Z
NAPCQ
P64
DatabaseName Docstoc
Technology Research Database
Engineering Research Database
ProQuest Health & Medical Complete (Alumni)
Biochemistry Abstracts 1
Nursing & Allied Health Premium
Biotechnology and BioEngineering Abstracts
DatabaseTitle Nursing & Allied Health Premium
Technology Research Database
Docstoc
Biochemistry Abstracts 1
ProQuest Health & Medical Complete (Alumni)
Engineering Research Database
Biotechnology and BioEngineering Abstracts
DatabaseTitleList Nursing & Allied Health Premium
Nursing & Allied Health Premium
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1535-5667
GeographicLocations Germany
GeographicLocations_xml – name: Germany
GroupedDBID ---
-~X
.55
29L
2WC
4T-
53G
5RE
8FD
8R4
8R5
8WZ
A6W
ABSQV
ACGOD
ACIWK
ACPRK
ADDZX
ADMOG
AENEX
AFOSN
AFRAH
AHMBA
ALIPV
ALMA_UNASSIGNED_HOLDINGS
CS3
DIK
DU5
E3Z
EBD
EBS
EJD
EMOBN
F5P
F9R
FR3
H13
I-F
INIJC
K9.
KQ8
L7B
M7Z
NAPCQ
OK1
P2P
P64
Q2X
R0Z
RHI
RNS
RWL
SJN
SV3
TAE
TR2
TSM
TUS
W8F
WH7
WOQ
X7M
YHG
ID FETCH-LOGICAL-p565-a56d2e43c4084a812883ada2f1a164a339956e8ce5a7fd94b8045a455c44d4ff3
ISSN 0161-5505
IngestDate Mon Jun 30 10:45:31 EDT 2025
Mon Jun 30 10:37:55 EDT 2025
IsPeerReviewed true
IsScholarly true
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-p565-a56d2e43c4084a812883ada2f1a164a339956e8ce5a7fd94b8045a455c44d4ff3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
PQID 2131599880
PQPubID 40808
ParticipantIDs proquest_journals_2435546925
proquest_journals_2131599880
PublicationCentury 2000
PublicationDate 20180501
PublicationDateYYYYMMDD 2018-05-01
PublicationDate_xml – month: 05
  year: 2018
  text: 20180501
  day: 01
PublicationDecade 2010
PublicationPlace New York
PublicationPlace_xml – name: New York
PublicationTitle The Journal of nuclear medicine (1978)
PublicationYear 2018
Publisher Society of Nuclear Medicine
Publisher_xml – name: Society of Nuclear Medicine
SSID ssj0006888
Score 2.2467687
Snippet Objectives: Accurate estimation of PET attenuation coefficients (AC) is a challenging problem in PET/MR1. Current MR-based AC method widely used in the PET/MR...
SourceID proquest
SourceType Aggregation Database
StartPage 652
SubjectTerms 3-D technology
Accuracy
Attenuation coefficients
Background radiation
Bone density
Chemical equilibrium
Computed tomography
Containers
Error correction & detection
Fast Fourier transformations
Fourier transforms
Gelatin
Ground truth
Health care
Image acquisition
Image reconstruction
Inhomogeneity
Medical imaging
Muscles
Organic chemistry
Positron emission
Positron emission tomography
Proton density (concentration)
Representations
Scanners
Soft tissues
Tibia
Tissue engineering
Tomography
Title PET-MR Attenuation Correction using 3D Multi-Echo Dixon-Based UTE Sequence
URI https://www.proquest.com/docview/2131599880
https://www.proquest.com/docview/2435546925
Volume 59
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bS8MwGA1uD-KLeMXLlDz4NiJNm7Td43Qd9bIhWmFvI00yJsomcwPx1_s16dqKQ9SXUFrahp7k5OTrd0HozJFCeNRVhIkQmgCmYpqVDNOuAj0cBm5q6qf0-n78yK4HfFBW2zTRJfP0XH6sjCv5D6pwDnDNomT_gGzxUDgBx4AvtIAwtL_C-C5KSO--2Z6D8LUpu2F-zwyHweHCmAG8TtME2ZIIiA4Y7n06IRewdKnmYxIBVVhP6qpGLaPFXqybh8xKSxR_4U1qJ9gVVmwIsbWiVr0M4-nMskgn-zNduP3Y4teDJzGV40UxLrvieWwj3q2J_q0ZvVTNETQsnf-sOTL3NTXmDtu9XtVJILdi-pRkWyO7CC2ZlxPQlkGVmvNk4ZZbfZvq9mvO7Lj9MLzrdIe3V_2bGqp51Gyrr26K1dgPTe3R4pXf1lwjJJIttJl_Wdy2cG6jNT3ZQevL7u-ia4sqrqCKS1SxQRV7HVyiiiuoYkAVL1HdQ0k3Si5jkle8IK8grIngvnI18yRzQpg7NKsELZRwR1TArlZ4JgxZh1JzEYxUi6UhCHLBOJeMKTYaefuoPplO9AHCLaaV5CBOqdDMkYGgoRYgPrnDfN9R9BA1lp9hmI_ot6FLPVC3LaD01ZdZJk79lsuPfr77GG2UQ6OB6vPZQp-AdpunpwacTwevRYc
linkProvider Flying Publisher
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=PET-MR+Attenuation+Correction+using+3D+Multi-Echo+Dixon-Based+UTE+Sequence&rft.jtitle=The+Journal+of+nuclear+medicine+%281978%29&rft.au=Han%2C+Paul&rft.au=Horng%2C+Debra&rft.au=Lai%2C+Xiaochun&rft.au=Fakhri%2C+Georges+El&rft.date=2018-05-01&rft.pub=Society+of+Nuclear+Medicine&rft.issn=0161-5505&rft.eissn=1535-5667&rft.volume=59&rft.spage=652&rft.externalDBID=HAS_PDF_LINK
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0161-5505&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0161-5505&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0161-5505&client=summon