Interference Detection and Quality Assessment of Pulse Signal on Android Platform
The collection process of the pulse signal is easily disturbed by the noise, that will reduce the quality of the signal, and affect its applications on the healthy monitoring system. In order to solve this problem, this paper analyzes the causes of the generation of interference during pulse signal...
Saved in:
Published in | Zhongguo yi liao qi xie za zhi Vol. 42; no. 5; p. 321 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | Chinese |
Published |
China
30.09.2018
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | The collection process of the pulse signal is easily disturbed by the noise, that will reduce the quality of the signal, and affect its applications on the healthy monitoring system. In order to solve this problem, this paper analyzes the causes of the generation of interference during pulse signal acquisition and the characteristics of interference performance, and puts forward the corresponding detection algorithm for pulse signal interference section. Based on this algorithm, a Cascaded Layer-by-Layer Discrimination method is proposed to evaluate the quality of pulse signals, in which pulse signals are divided into available signals and unavailable signals. Experimental results on PC and Android platform show that the proposed algorithm can detect the interference segment accurately in the pulse signal in real time, and improve the usability of the evaluation for pulse signal. |
---|---|
AbstractList | The collection process of the pulse signal is easily disturbed by the noise, that will reduce the quality of the signal, and affect its applications on the healthy monitoring system. In order to solve this problem, this paper analyzes the causes of the generation of interference during pulse signal acquisition and the characteristics of interference performance, and puts forward the corresponding detection algorithm for pulse signal interference section. Based on this algorithm, a Cascaded Layer-by-Layer Discrimination method is proposed to evaluate the quality of pulse signals, in which pulse signals are divided into available signals and unavailable signals. Experimental results on PC and Android platform show that the proposed algorithm can detect the interference segment accurately in the pulse signal in real time, and improve the usability of the evaluation for pulse signal. |
Author | Wang, Jingyang Qi, Yusheng Kou, Xinyu Zhang, Aihua |
Author_xml | – sequence: 1 givenname: Aihua surname: Zhang fullname: Zhang, Aihua organization: National Demonstration Center for Experimental and Control Engineering Education, Lanzhou University of Technology, Lanzhou, 730050 – sequence: 2 givenname: Xinyu surname: Kou fullname: Kou, Xinyu organization: National Demonstration Center for Experimental and Control Engineering Education, Lanzhou University of Technology, Lanzhou, 730050 – sequence: 3 givenname: Yusheng surname: Qi fullname: Qi, Yusheng organization: College of Electrical and Information Engineering, Lanzhou University of Technology, Lanzhou, 730050 – sequence: 4 givenname: Jingyang surname: Wang fullname: Wang, Jingyang organization: Key Laboratory of Gansu Advanced Control for Industrial Processes, Lanzhou, 730050 |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/30358341$$D View this record in MEDLINE/PubMed |
BookMark | eNo9j71qwzAURjWkNGmaVygautrVlSzZGk3apoFAE9I9yNZVUbFlY9lD3r6G_kwfHA4HvjuyCF1AQh6BpUIr_fSV-hhDCiqHJAeWpZxBkTKZMiYWZPXPl2QTo68YUznTAPKWLAUTshAZrMhpH0YcHA4YaqTPOGI9-i5QEyw9Tabx45WWMWKMLYaRdo4epyYiPfvPYBo6m2WwQ-ctPTZmdN3Q3pMbZ2Zl87trcn59-di-JYf33X5bHpJeKkgEVNbJrM7RSStMgdJJLoy2UM9cZBYV1zrngMZKw8C5QgCvlQBRQF7xNXn4qfZT1aK99INvzXC9_D3j30osVKY |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.3969/j.issn.1671-7104.2018.05.003 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
ExternalDocumentID | 30358341 |
Genre | Journal Article |
GroupedDBID | --- -05 5XA 5XD 5XF ACGFS ALMA_UNASSIGNED_HOLDINGS CCEZO CGR CIEJG CUY CVF CW9 ECM EIF F5P NPM U1G U5M U5O |
ID | FETCH-LOGICAL-p561-31bdf54c7ef5d3a8e5f523a9d1cdf534de6299721ead5a01ff8312c6313817b2 |
ISSN | 1671-7104 |
IngestDate | Thu May 23 23:51:33 EDT 2024 |
IsPeerReviewed | false |
IsScholarly | true |
Issue | 5 |
Keywords | quality evaluation Cascaded Layer-by-Layer Discrimination pulse signal Android |
Language | Chinese |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-p561-31bdf54c7ef5d3a8e5f523a9d1cdf534de6299721ead5a01ff8312c6313817b2 |
PMID | 30358341 |
ParticipantIDs | pubmed_primary_30358341 |
PublicationCentury | 2000 |
PublicationDate | 2018-Sep-30 |
PublicationDateYYYYMMDD | 2018-09-30 |
PublicationDate_xml | – month: 09 year: 2018 text: 2018-Sep-30 day: 30 |
PublicationDecade | 2010 |
PublicationPlace | China |
PublicationPlace_xml | – name: China |
PublicationTitle | Zhongguo yi liao qi xie za zhi |
PublicationTitleAlternate | Zhongguo Yi Liao Qi Xie Za Zhi |
PublicationYear | 2018 |
SSID | ssib006709115 ssj0042023 ssib005319411 ssib001103627 ssib051368559 ssib018830214 |
Score | 2.1933088 |
Snippet | The collection process of the pulse signal is easily disturbed by the noise, that will reduce the quality of the signal, and affect its applications on the... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 321 |
SubjectTerms | Algorithms Electrocardiography Heart Rate Signal Processing, Computer-Assisted |
Title | Interference Detection and Quality Assessment of Pulse Signal on Android Platform |
URI | https://www.ncbi.nlm.nih.gov/pubmed/30358341 |
Volume | 42 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3fa9swEBbpBqUvZWO_tw499M24qyzJdh5D11E2VhjtINtLkS0pNmx2xmxo8rC_vXey7HjZ772YIAUR5b6cvrvcfSLk0CaJiU0G0YlMp6FQJguzWOhQRbnikcmlUtiN_PY8PnsvXs_lfDL5Nu4uabKjfP3TvpL_sSqMgV2xS_YfLDssCgPwGuwLT7AwPP_Kxi6d1wvFvjSN8fd-VzrotDFWwWxQ3nTVbi2chMFFuXActHLljHWp8eqiBtnrmKp-LOpqsWjrYFUGn0pVB1_K4Lo0wVoF66L8IeE8K4t2cPFv6hbH5mW1aofUqqsb-NB-LYw_LV0e31cEwwm6Un7cJyHYUDEx-M04YVjWKcaOVUQjAMmRl-RdU_S29-bTeOq8Ny55NCyJ9Xepk1d1agjNyLDLz86ycAzLlAv259ktbe1-aofsJCl6yfNRrgeIEZzuyXfeSoy8ISrfsQ2ZYilKqW3-k5YMtf2RLHa8QOBF9Rj-9_vaJYd-0y9-t-U9stt_zK3Qx1Ggyztk38cudNYB8S6ZrIt75N0YhHQAIQUQUg9CugEhrS11IKQdCCm804OQ9iC8Ty5enV6enIX-no5wKTF7yTJtpcgTY6XmKjXSyoirqWY5jHOhTRxhezYDpyXVMbM25SzKY85QHTKLHpBbVV2ZR4RCKKyBU8pMCyFseqy4RsZquRaZjdL4MXnY7f9q2UmxXPXfzJNfzjwlexvAPiO3Lfz2zQEQySZ77ux9Aw2sZqo |
link.rule.ids | 783 |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Interference+Detection+and+Quality+Assessment+of+Pulse+Signal+on+Android+Platform&rft.jtitle=Zhongguo+yi+liao+qi+xie+za+zhi&rft.au=Zhang%2C+Aihua&rft.au=Kou%2C+Xinyu&rft.au=Qi%2C+Yusheng&rft.au=Wang%2C+Jingyang&rft.date=2018-09-30&rft.issn=1671-7104&rft.volume=42&rft.issue=5&rft.spage=321&rft_id=info:doi/10.3969%2Fj.issn.1671-7104.2018.05.003&rft_id=info%3Apmid%2F30358341&rft_id=info%3Apmid%2F30358341&rft.externalDocID=30358341 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1671-7104&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1671-7104&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1671-7104&client=summon |