Problems in cochlear implant surgery

In cochlear implant surgery, major complications, requiring revision procedures, do not exceed 5% of cases reported. Less frequent are problems that call for specific technical solutions. In 44 multichannel implantations (out of 54 cases) adverse conditions occurred and were successfully resolved in...

Full description

Saved in:
Bibliographic Details
Published inActa otorhino-laryngologica italica Vol. 16; no. 2; pp. 105 - 108
Main Authors Trabalzini, F, Babighian, G
Format Journal Article
LanguageItalian
Published Italy 01.04.1996
Subjects
Online AccessGet full text

Cover

Loading…
Abstract In cochlear implant surgery, major complications, requiring revision procedures, do not exceed 5% of cases reported. Less frequent are problems that call for specific technical solutions. In 44 multichannel implantations (out of 54 cases) adverse conditions occurred and were successfully resolved in 6 patients: 1) delayed wound breakdown (one case); 2) chronic otitis media (three cases); 3) cochlear obliteration (two cases). Problem 1 was managed with the excision of an ellipse of skin including the devitalized areas under local anesthesia. The electronic package was left untouched, and the freshly cutaneous edges were mobilized and layer-sutured. Problem 2 was solved through a two-stage procedure. The chronic ear was dealt with as usual (myringoplasty, tympanoplasty, revision of a radical mastoidectomy). In the second stage the cochleotomy and device implantation were carried out. Problem 3 is a major issue for the surgeon. Following the Lehnhardt technique we drilled along the basal cochlear turn using the sharp line between the yellowish otic bone and the white newly formed bone as a landmark, until a patent s.tympani was found at the ascending part of the 1st or at the beginning of the 2nd turn.
AbstractList In cochlear implant surgery, major complications, requiring revision procedures, do not exceed 5% of cases reported. Less frequent are problems that call for specific technical solutions. In 44 multichannel implantations (out of 54 cases) adverse conditions occurred and were successfully resolved in 6 patients: 1) delayed wound breakdown (one case); 2) chronic otitis media (three cases); 3) cochlear obliteration (two cases). Problem 1 was managed with the excision of an ellipse of skin including the devitalized areas under local anesthesia. The electronic package was left untouched, and the freshly cutaneous edges were mobilized and layer-sutured. Problem 2 was solved through a two-stage procedure. The chronic ear was dealt with as usual (myringoplasty, tympanoplasty, revision of a radical mastoidectomy). In the second stage the cochleotomy and device implantation were carried out. Problem 3 is a major issue for the surgeon. Following the Lehnhardt technique we drilled along the basal cochlear turn using the sharp line between the yellowish otic bone and the white newly formed bone as a landmark, until a patent s.tympani was found at the ascending part of the 1st or at the beginning of the 2nd turn.
Author Trabalzini, F
Babighian, G
Author_xml – sequence: 1
  givenname: F
  surname: Trabalzini
  fullname: Trabalzini, F
  organization: Divisione di Otorinolaringoiatria, Ospedali Civili Riuniti, Venezia
– sequence: 2
  givenname: G
  surname: Babighian
  fullname: Babighian, G
BackLink https://www.ncbi.nlm.nih.gov/pubmed/8766072$$D View this record in MEDLINE/PubMed
BookMark eNotjztPwzAURj0UlbbwE5AyILZIN_HjxiOqeEmVYOjAFtnODQTZcbCbof-eSmQ6y9HR923ZaowjrdgGuK7LCuDzmm1z_gEQiE21ZusGlQKsN-z-I0XrKeRiGAsX3bcnk4ohTN6MpyLP6YvS-YZd9cZnul24Y8fnp-P-tTy8v7ztHw_lJHldSgldZbXUzoIA3SPnAkBhpbXsahK9QqONkc6hEhV2DXJQvXWOlLBkFd-xh__slOLvTPnUhiE78pcpFOfcYlMLqUFcxLtFnG2grp3SEEw6t8sr_gdm1Uf7
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
7X8
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic
MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
DocumentTitleAlternate Problemi nella chirurgia dell'impianto cocleare
EndPage 108
ExternalDocumentID 8766072
Genre English Abstract
Journal Article
GroupedDBID 23M
2WC
53G
5GY
ACGFO
ADBBV
AENEX
ALMA_UNASSIGNED_HOLDINGS
AOIJS
BAWUL
C1A
CGR
CUY
CVF
DIK
E3Z
ECM
EIF
GROUPED_DOAJ
GX1
HYE
KQ8
M~E
NPM
OK1
P2P
RNS
RPM
TR2
7X8
ID FETCH-LOGICAL-p532-550d1b959cb0409f733400671995d2e4f67a9aa5cc76417d87306fbcce64beb63
ISSN 0392-100X
IngestDate Sat Aug 17 02:28:09 EDT 2024
Sat Sep 28 07:33:26 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 2
Language Italian
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-p532-550d1b959cb0409f733400671995d2e4f67a9aa5cc76417d87306fbcce64beb63
Notes ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
PMID 8766072
PQID 78245904
PQPubID 23479
PageCount 4
ParticipantIDs proquest_miscellaneous_78245904
pubmed_primary_8766072
PublicationCentury 1900
PublicationDate 1996-Apr
19960401
PublicationDateYYYYMMDD 1996-04-01
PublicationDate_xml – month: 04
  year: 1996
  text: 1996-Apr
PublicationDecade 1990
PublicationPlace Italy
PublicationPlace_xml – name: Italy
PublicationTitle Acta otorhino-laryngologica italica
PublicationTitleAlternate Acta Otorhinolaryngol Ital
PublicationYear 1996
SSID ssj0047781
Score 1.4356363
Snippet In cochlear implant surgery, major complications, requiring revision procedures, do not exceed 5% of cases reported. Less frequent are problems that call for...
SourceID proquest
pubmed
SourceType Aggregation Database
Index Database
StartPage 105
SubjectTerms Cochlear Implants
Deafness - rehabilitation
Humans
Postoperative Complications
Retrospective Studies
Title Problems in cochlear implant surgery
URI https://www.ncbi.nlm.nih.gov/pubmed/8766072
https://search.proquest.com/docview/78245904
Volume 16
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3LSsNAFB1sQelGfBXrM4vuSiRpJpPOsoq2CIqLCt2VecUGalJsurBf753JNK2PgroJIQkhOYfcOXdy7lyEmiApzFJlLkj_0MWSSRdUOHE7kgbCFwIGDeO2eCT9Z3w_DIer5qumuiTnV2LxY13Jf1iFY8CrrpL9A7PlTeEA7AO_sAWGYfsrjp-KbjDG0gqBbaxbQOi6xwnA1Zp9L3juipy1Msiyx0mauZDTvqcvNvi1dPOQNd_OQP_rnywS0_FpZf-9Zhyy-aSYNe2tpgwKl3HpNLGlUrQN8dcbfgqDZI3u9lpM801ddL6G5_TVAAqBlHhF450va1bbMxVUCXzts-wNS98NjiLTObZ8hhratpdvFvlmsB_soV2r0p1uAfk-2kryA7TzYH0Ih6i5RN5JUmeJvGORdyzyR2hwdzu46bu234Q7DQNIyUNP-pyGVHCIbDSOggDrwVwXscu2wjGJGGUsFCIi2I9kB4IjibkQimCuOAnqqJpmqTpGDmTd-l5SxrFej4cxJSXnoE1BECrl0Qa6XL7pCD5n_Y-GpSqbz0Yg2HBIPdxA9QKA0bRYdWRkQTrZdOIU1VZcn6Fq_jZX5yCYcn5hCPgAf00YYA
link.rule.ids 315,786,790
linkProvider Geneva Foundation for Medical Education and Research
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Problems+in+cochlear+implant+surgery&rft.jtitle=Acta+otorhino-laryngologica+italica&rft.au=Trabalzini%2C+F&rft.au=Babighian%2C+G&rft.date=1996-04-01&rft.issn=0392-100X&rft.volume=16&rft.issue=2&rft.spage=105&rft_id=info%3Apmid%2F8766072&rft.externalDocID=8766072
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0392-100X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0392-100X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0392-100X&client=summon